journal article·2025-12Open access

Implantable electrochemical biosensors: Challenges, strategies, and applications

Sondes Ben-Aissa, Suryasnata Tripathy, Anthony Edward George Cass

Abstract

Applying biosensor technologies to continuous, real-time measurements in living creatures, including humans, offers an exciting range of possibilities for a better understanding of both normal physiology and disease. It also comes with a collection of technical, ethical and regulatory needs that render the transition of electrochemical biosensors from in vitro to in vivo exceptionally challenging. In this review, we address the advances in the components of implantable electrochemical biosensors. These include the integration of molecular recognition elements, materials design, supply of electrical power, fabrication of instrumentation packages and communications protocols. Significant challenges that remain include those associated with biocompatibility, sterility, device lifetime, calibration and user acceptability. Regulatory aspects whether of medical or consumer devices are essential to address and need to be an early consideration in device design, as are the use cases to which the implanted sensor will ultimately address.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Electrochemical sensors and biosensors · Neuroscience and Neural Engineering · Conducting polymers and applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (53)

Show source-provided references
1. Electrochemical studies of the oxidation pathways of catecholamines10.1021/ja00978a051 ↗
2. Polarographic measurement of cerebral oxygenation using chronically implanted electrodes10.1152/jappl.1959.14.3.480 ↗
3. In vivo electrochemical biosensors: recent advances in molecular design, electrode materials, and electrochemical devices10.1021/acs.analchem.2c04541 ↗
4. Fibrotic encapsulation is the dominant source of continuous glucose monitor delays10.2337/db19-0229 ↗
5. Materials strategies to overcome the foreign body response10.1002/adhm.202304478 ↗
6. Implantable application of polymer-based biosensors10.1002/pol.20210543 ↗
7. Effect of protection polymer coatings on the performance of an amperometric galactose biosensor in human plasma
8. How pH affects electrochemical processes10.1126/science.abj2421 ↗
9. Tuning the localized microenvironment near a continuous glucose meter to ensure monitoring accuracy and longevity by plasma-induced grafting zwitterionic brushes10.1021/acssensors.4c01921 ↗
10. Electrochemical microelectrode degradation monitoring: in situ investigation of platinum corrosion at neutral pH10.1088/1741-2552/ac47da ↗
11. Biocompatible reference electrodes to enhance chronic electrochemical signal fidelity in vivo10.1007/s00216-021-03640-w ↗
12. Effect of interstitial fluid pH on transdermal glucose extraction by reverse iontophoresis10.1016/j.bios.2023.115406 ↗
13. Implantable hydrogel-protective DNA aptamer-based sensor supports accurate, continuous electrochemical analysis of drugs at multiple sites in living rats10.1021/acsnano.3c06520 ↗
14. Fully printed and self-compensated bioresorbable electrochemical devices based on galvanic coupling for continuous glucose monitoring
15. Room vs. body temperature to evaluate electrical interface parameters of state-of-the-art PEDOT: PSS-based electrodes10.1002/celc.202400459 ↗
16. Implantable flexible sensors for health monitoring10.1002/adhm.202302460 ↗
17. Dual-aptamer drift canceling techniques to improve long-term stability of real-time structure-switching aptasensors10.1021/acssensors.3c00509 ↗
18. The advances in zwitterionic materials and their biomedical applications
19. Anti-biofouling strategies for long-term continuous use of implantable biosensors10.3390/chemosensors8030066 ↗
20. Metal nanoparticles and carbon-based nanomaterials for improved performances of electrochemical (bio)sensors with biomedical applications10.3390/ma14216319 ↗
21. An antimicrobial and antifibrotic coating for implantable biosensors
22. Antifouling strategies for selective in vitro and in vivo sensing10.1021/acs.chemrev.9b00739 ↗
23. Long-term monitoring of ultratrace nucleic acids using tetrahedral nanostructure-based NgAgo on wearable microneedles10.1038/s41467-024-46215-w ↗
24. Nature-inspired surface modification strategies for implantable devices
25. Advances in bioresorbable materials and electronics10.1021/acs.chemrev.3c00408 ↗
26. Conformal fixation strategies and bioadhesives for soft bioelectronics10.1002/adfm.202313728 ↗
27. Microneedle system for tissue engineering and regenerative medicine
28. Bio-acceptability of wearable sensors: a mechanistic study towards evaluating ionic leaching induced cellular inflammation10.1038/s41598-022-13810-0 ↗
29. Hydrogen peroxide sensing with cochlear implants in vivo: towards intra-operative trauma detection10.1016/j.snb.2025.137789 ↗
30. Poly(Glycerol sebacate) in biomedical applications—A review of the recent literature10.1002/adhm.202002026 ↗
31. Review and perspectives of sustainable, biodegradable, eco-friendly and flexible electronic devices and (bio)sensors
32. Biodegradable implantable sensors: materials design, fabrication, and applications
33. Recent progress and challenges of implantable biodegradable biosensors10.3390/mi15040475 ↗
34. A current development of energy harvesting systems for energy-independent bioimplantable biosensors10.1002/smll.202403899 ↗
35. Self-powered cardiac pacemaker by piezoelectric polymer nanogenerator implant10.1016/j.nanoen.2021.105781 ↗
36. Wireless power transfer system for deep-implanted biomedical devices10.1038/s41598-022-18000-6 ↗
37. Thermoelectric energy harvesting for implantable medical devices
38. Review of flexible energy harvesting for bioengineering in alignment with SDG10.1016/j.mser.2023.100763 ↗
39. Biodegradable triboelectric nanogenerator as a implantable power source for embedded medicine devices10.1038/s41427-023-00528-2 ↗
40. Skin-integrated wearable systems and implantable biosensors: a comprehensive review10.3390/bios10070079 ↗
41. Device integration of electrochemical biosensors10.1038/s44222-023-00032-w ↗
42. Advances in continuous glucose monitoring and integrated devices for management of diabetes with insulin-based therapy: improvement in glycemic control10.4093/dmj.2022.0271 ↗
43. Advancements in electrochemical biosensing of cardiovascular disease biomarkers10.1039/D4TB00333K ↗
44. Implantable biosensors for long-term monitoring of cardiac health
45. Challenges and strategies faced in the electrochemical biosensing analysis of neurochemicals in vivo: a review10.1016/j.talanta.2023.124933 ↗
46. Real-time monitoring and early warning of a cytokine storm in vivo using a wearable noninvasive skin microneedle patch
47. Continuous measurement of lactate concentration in human subjects through direct electron transfer from enzymes to microneedle electrodes10.1021/acssensors.2c02780 ↗
48. Monitoring with in vivo electrochemical sensors: navigating the complexities of blood and tissue reactivity10.3390/s20113149 ↗
49. A practical approach to continuous glucose monitoring (rtCGM) and FreeStyle Libre systems (isCGM) in children and young people with Type 1 diabetes10.1016/j.diabres.2022.109196 ↗
50. Reagentless biomolecular analysis using a molecular pendulum10.1038/s41557-021-00644-y ↗
51. Implantable cardiac patch continuously monitors acute heart failure biomarkers in vivo and ex vivo10.1016/j.jacbts.2025.01.011 ↗
52. A tissue-like neurotransmitter sensor for the brain and gut10.1038/s41586-022-04615-2 ↗
53. Estimated cost of developing a therapeutic complex medical device in the US10.1001/jamanetworkopen.2022.31609 ↗