journal article·2025-12Open access

Electrochemical lateral flow assays: A new frontier for rapid and quantitative biosensing

Vernalyn Abarintos, Andrew Piper, Arben Merkoci

Abstract

Electrochemical lateral flow assays (eLFAs) have emerged as a promising alternative to traditional colorimetric LFAs, particularly for applications requiring quantitative readouts and improved sensitivity. Over the past two years, significant advancements have been made in eLFA design, fabrication, and analytical performance, positioning them as promising candidates for decentralized diagnostics and point-of-care (POC) testing. This review highlights recent advances in electrode integration techniques, redox-based signal amplification strategies, and the incorporation of wireless and battery-free electrochemical readout platforms. Multiplexed detection and real-time wireless data transmission have also been demonstrated, further increasing the utility of eLFAs in clinical and field settings. Additionally, innovative strategies to control contact pressure, optimize sample flow, and maintain device stability are being explored to improve reproducibility and usability. Despite these advancements, challenges remain, including biofouling, variability in sample matrices, and the need for standardized protocols across platforms.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Advanced biosensing and bioanalysis techniques · Biosensors and Analytical Detection · Electrochemical Analysis and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (29)

Show source-provided references
1. Tutorial: design and fabrication of nanoparticle-based lateral-flow immunoassays10.1038/s41596-020-0357-x ↗
2. Lateral flow (immuno)Assay: its strengths, weaknesses, opportunities and threats. A literature survey10.1007/s00216-008-2287-2 ↗
3. Lateral flow assay: a point of care solution
4. Lateral flow assays: principles, designs and labels10.1016/j.trac.2016.06.006 ↗
5. Enhancing the analytical performance of paper lateral flow assays: from chemistry to engineering10.1016/j.trac.2021.116200 ↗
6. An artificial miniaturized peroxidase for signal amplification in lateral flow immunoassays10.1002/smll.202207949 ↗
7. Toward next generation lateral flow assays: integration of nanomaterials10.1021/acs.chemrev.1c01012 ↗
8. Lateral flow assays: progress and evolution of recent trends in point-of-care applications
9. Integrating high-performing electrochemical transducers in lateral flow assay10.1007/s00216-021-03301-y ↗
10. Beyond the lateral flow assay: a review of paper-based microfluidics10.1016/j.mee.2018.12.002 ↗
11. Electrochemical lateral flow devices: towards rapid immunomagnetic assays10.1002/celc.201600902 ↗
12. Transitions in immunoassay leading to next-generation lateral flow assays and future prospects10.3390/biomedicines12102268 ↗
13. An interference-free and rapid electrochemical lateral-flow immunoassay for one-step ultrasensitive detection with serum10.1039/C3AN02328A ↗
14. Ratiometric electrochemical lateral flow immunoassay for the detection of Streptococcus suis serotype 210.1016/j.bios.2023.115742 ↗
15. Electrochemical lateral flow immunosensor with enhanced reproducibility for milk allergen detection10.1016/j.snb.2023.135042 ↗
16. TEMPO-based immuno-lateral flow quantitative detection of dengue NS1 protein10.1016/j.snb.2017.12.043 ↗
17. Rapid prototyping of electrochemical lateral flow devices: stencilled electrodes10.1039/C5AN02424B ↗
18. Integrated lateral flow electrochemical strip for leptospirosis diagnosis10.1021/acs.analchem.1c04440 ↗
19. Rapid electrochemical lateral flow device for the detection of Δ9-tetrahydrocannabinol10.1016/j.aca.2023.341768 ↗
20. Hybrid nanoflower-based electrochemical lateral flow immunoassay for Escherichia coli O157 detection10.1007/s00604-024-06513-y ↗
21. Redox cycling amplified electrochemical lateral-flow immunoassay: toward decentralized sensitive insulin detection10.1021/acssensors.3c01445 ↗
22. Electrochemical lateral flow immunoassay with Built-In electrodes for ultrasensitive and wireless detection of inflammatory biomarkers10.1021/acs.analchem.4c01224 ↗
23. NFC-enabled potentiostat and nitrocellulose-based metal electrodes for electrochemical lateral flow assay10.1016/j.bios.2024.116124 ↗
24. Electrochemical lateral-flow device for rapid COVID-19 antigen-diagnostic testing10.1016/j.bioelechem.2023.108438 ↗
25. Quantitative detection of C-reactive protein in human saliva using an electrochemical lateral flow device
26. Integrated electrochemical lateral flow immunoassays (eLFIAs): recent advances10.1039/D1AN01478A ↗
27. Lateral flow assay HIV-based microfluidic blood fuel cell10.1088/1742-6596/1119/1/012022 ↗
28. Reduced graphene oxide electrodes meet lateral flow assays: a promising path to advanced point-of-care diagnostics10.1016/j.bios.2024.116315 ↗
29. Studying ion transport dynamics in electrochemical measurements of lateral flow assays10.1016/j.jelechem.2024.118399 ↗