Summary Long-term implantable glucose sensors with a demonstrated lifetime of at least two weeks play a key role in continuous glucose monitoring (CGM) and the development of closed-loop artificial pancreas systems for the emerging number of diabetes patients. This short review summarises the current state of the art of CGM systems and points out specific limitations of amperometric glucose biosensors regarding their inherent sensor long-term and signal stability that are mainly caused by the inevitable foreign body response after sensor implantation.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Electrochemical sensors and biosensors · Advanced biosensing and bioanalysis techniques · Analytical Chemistry and Sensors
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (59)
Show source-provided references
1. Electrode systems for continuous monitoring in cardiovascular surgery10.1111/j.1749-6632.1962.tb13623.x ↗
2. Bio-sensors based on ion-selective electrodes10.1007/BF00539519 ↗
3. Glucose biosensors: 40 years of advances and challenges10.1002/1521-4109(200108)13:12<983::AID-ELAN983>3.0.CO;2-# ↗
4. Electrochemical glucose biosensors10.1021/cr068123a ↗
5. Recent advances in electrochemical glucose biosensors. A review10.1039/c2ra22351a ↗
6. Biosensors in clinical chemistry10.1016/S0009-8981(03)00241-9 ↗
7. Amperometric biosensors
8. Development of an implantable electrocatalytic glucose sensor10.1016/0302-4598(78)80002-6 ↗
9. A telemetering system for securing data on the motility of internal organs10.1109/TBME.1966.4502425 ↗
10. Wearable continuous glucose monitoring sensors. A revolution in diabetes treatment10.3390/electronics6030065 ↗
11. Current and emerging technology for continuous glucose monitoring10.3390/s17010182 ↗
12. The benefits of implanted glucose sensors10.1177/193229680700100601 ↗
13. Realistic expectations and practical use of continuous glucose monitoring for the endocrinologist10.1210/jc.2008-2625 ↗
14. Can continuous glucose monitoring be used for the treatment of diabetes
15. Implantable enzyme amperometric biosensors10.1016/j.bios.2012.03.016 ↗
16. Bard · 2001
17. Amperometric enzyme biosensors based on optimised electron-transfer pathways and non-manual immobilisation procedures10.1016/S1389-0352(01)00058-7 ↗
18. The performance and usability of a factory-calibrated flash glucose monitoring system10.1089/dia.2014.0378 ↗
19. Towards smart tattoos. Implantable biosensors for continuous glucose monitoring10.1002/adhm.201200167 ↗
20. Approaches toward allowing electroanalytical devices to be used in biological fluids10.1002/elan.201400097 ↗
21. Enzyme-catalyzed direct electron transfer. Fundamentals and analytical applications10.1002/elan.1140090902 ↗
22. Cellobiose dehydrogenase. Insights on the nanostructuration of electrodes for improved development of biosensors and biofuel cells10.1016/j.apmt.2017.08.009 ↗
23. Recombinantly produced cellobiose dehydrogenase from Corynascus thermophilus for glucose biosensors and biofuel cells10.1002/biot.201200049 ↗
24. Cellobiose dehydrogenase: a versatile catalyst for electrochemical applications10.1002/cphc.201000216 ↗
25. Significant improvement of thermal stability of glucose 1-dehydrogenase by introducing disulfide bonds at the tetramer interface10.1016/j.enzmictec.2013.08.001 ↗
26. Designing a highly active soluble PQQ-glucose dehydrogenase for efficient glucose biosensors and biofuel cells10.1016/j.bbrc.2010.10.102 ↗
27. Electron transfers in chemistry and biology10.1016/0304-4173(85)90014-X ↗
28. Native glucose oxidase does not undergo direct electron transfer10.1016/j.bios.2016.04.083 ↗
29. There is no evidence to support literature claims of direct electron transfer (DET) for native glucose oxidase (GOx) at carbon nanotubes or graphene
30. Redox polymers in bioelectrochemistry. Common playgrounds and novel concepts10.1016/j.coelec.2017.06.007 ↗
31. Electrochemistry in diabetes management10.1021/ar9002015 ↗
32. Electrical wiring of redox enzymes
33. Identification and structural analysis of amino acid substitutions that increase the stability and activity of aspergillus niger glucose oxidase10.1371/journal.pone.0144289 ↗
34. Modification of galactose oxidase to introduce glucose 6-oxidase activity10.1002/1439-7633(20020802)3:8<781::AID-CBIC781>3.0.CO;2-8 ↗
35. Design of an Os complex-modified hydrogel with optimized redox potential for biosensors and biofuel cells10.1002/chem.201504591 ↗
36. Direct evidence of acetaminophen interference with subcutaneous glucose sensing in humans. A pilot study
37. Oxygen reduction on redox mediators may affect glucose biosensors based on “wired” enzymes10.1016/j.electacta.2012.02.053 ↗
38. Enzyme biosensors for biomedical applications. Strategies for safeguarding analytical performances in biological fluids10.3390/s16060780 ↗
39. Measurement and modeling of the transient difference between blood and subcutaneous glucose concentrations in the rat after injection of insulin10.1073/pnas.95.1.294 ↗
40. Calibration of a subcutaneous amperometric glucose sensor10.1016/S0956-5663(01)00306-2 ↗
41. Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring
42. Accuracy and acceptability of the 6-day Enlite continuous subcutaneous glucose sensor10.1089/dia.2013.0222 ↗
43. Clinical accuracy of a continuous glucose monitoring system with an advanced algorithm10.1177/1932296814559746 ↗
44. A new-generation continuous glucose monitoring system. Improved accuracy and reliability compared with a previous-generation system10.1089/dia.2013.0077 ↗
45. Accuracy of a fourth-generation subcutaneous continuous glucose sensor10.1089/dia.2017.0087 ↗
46. FreeStyle navigator continuous glucose monitoring system with TRUstart algorithm, a 1-hour warm-up time10.1177/193229681100500114 ↗
47. Performance characterization of an abiotic and fluorescent-based continuous glucose monitoring system in patients with type 1 diabetes10.1016/j.bios.2014.05.022 ↗
48. Accuracy and longevity of an implantable continuous glucose sensor in the PRECISE study. A 180-Day, prospective, multicenter, pivotal trial10.2337/dc16-1525 ↗
49. "Smart" continuous glucose monitoring sensors. On-line signal processing issues10.3390/s100706751 ↗
50. Foreign body reaction to implantable biosensors. Effects of tissue trauma and implant size10.1177/1932296815601869 ↗
51. Biomaterials/tissue interactions. Possible solutions to overcome foreign body response10.1208/s12248-010-9175-3 ↗
52. Controlling the charge of pH-responsive redox hydrogels by means of redox-silent biocatalytic processes. A biocatalytic off/on switch10.1016/j.elecom.2014.12.001 ↗
53. Surface treatments of polymers for biocompatibility10.1146/annurev.ms.26.080196.002053 ↗
54. Antifouling zwitterionic coating via electrochemically mediated atom transfer radical polymerization on enzyme-based glucose sensors for long-time stability in 37°C serum10.1021/acs.langmuir.6b03016 ↗
55. Nitric oxide release for improving performance of implantable chemical sensors - A review10.1016/j.apmt.2017.10.002 ↗
56. Electrochemical properties of nanostructured porous gold electrodes in biofouling solutions10.1021/ac403013r ↗
57. Design, characterization, and one-point in vivo calibration of a subcutaneously implanted glucose electrode10.1021/ac00091a022 ↗
58. Continuous glucose monitoring, future products, and update on worldwide artificial pancreas projects
59. Wearable artificial endocrine pancreas with needle type glucose sensor10.1016/S0140-6736(82)92788-X ↗