Noninvasive monitoring of diabetes and hypoxia by wearable flow-through biosensors
Source abstract
Abstract
Abstract Noninvasively collected sweat via clinically relevant procedure can be used for assessing the human condition, particularly for monitoring of diabetes and hypoxia. Positive correlations in variation rates, claimed as sufficient requirements for diagnostics, between glucose and lactate concentrations in sweat and the corresponding values in blood are shown. Continuous monitoring of human condition is possible only with the use of flow-through wearable devices providing a delivery of sweat to the biosensor almost immediately after excretion. Owing to both low sweat glucose content and inactivation of platinum by sweat components, the use of Prussian blue–based biosensors for wearable devices is preferable. Operation of the latter in power generation mode allows significant noise reduction and clear readout of the signal. Evaluating blood glucose through sweat analysis upon glucose tolerance test, we clearly show that humans can actually be monitored reliably via noninvasive approach.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced Sensor and Energy Harvesting Materials · Non-Invasive Vital Sign Monitoring · Analytical Chemistry and Sensors
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (49)
Show source-provided references
1. Biosensors: sense and sensibility10.1039/c3cs35528d ↗
2. O2 deficit incurred during hypoxia and its relation to lactate and excess lactate10.1152/ajplegacy.1967.213.1.57 ↗
3. A lactate-induced response to hypoxia10.1016/j.cell.2015.03.011 ↗
4. Serial blood lactate levels can predict the development of multiple organ failure following septic shock10.1016/S0002-9610(97)89552-9 ↗
5. Lactic-acidosis in critical illness10.1097/00003246-199201000-00020 ↗
6. Anaerobic threshold: review of the concept and directions for future research10.1249/00005768-198502000-00005 ↗
7. Blood lactate - implications for training and sports performance10.2165/00007256-198603010-00003 ↗
8. Anaerobic threshold: the concept and methods of measurement10.1139/h03-023 ↗
9. Exercise-induced changes in blood ammonia levels in humans10.1007/BF00430955 ↗
10. Metabolic signatures of exercise in human plasma10.1126/scitranslmed.3001006 ↗
11. Lactate threshold concepts how valid are they?10.2165/00007256-200939060-00003 ↗
12. Non-invasive glucose monitoring: assessment of technologies and devices according to quantitative criteria10.1016/j.diabres.2006.10.027 ↗
13. Non-invasive glucose monitoring technology in diabetes management: a review10.1016/j.aca.2012.03.043 ↗
14. Multivariate calibration of NIR spectroscopic sensors for continuous glucose monitoring10.1016/j.trac.2014.12.005 ↗
15. Prospects and limitations of non-invasive blood glucose monitoring using near-infrared spectroscopy10.1016/j.bspc.2015.01.005 ↗
16. Reverse iontophoresis - development of a noninvasive approach for glucose monitoring10.1023/A:1018926215306 ↗
17. Electrode assembly for transcutaneous reverse-iontophoresis diagnostic system, especially for blood glucose determination
18. Sweat chloride in patients with chronic bronchial disease and its relation to mucoviscidosis (cystic fibrosis)
19. Sweat testing practice in Swiss hospitals10.4414/smw.2007.11719 ↗
20. Sweat testing practices in German cystic fibrosis centres10.1055/s-2007-872458 ↗
21. The secretion of sweat and vaso-dilatation produced by pilocarpine10.1113/jphysiol.1925.sp002255 ↗
22. A test for concentration of electrolytes in sweat in cystic fibrosis of the pancreas utilizing pilocarpine by iontophoresis10.1542/peds.23.3.545 ↗
23. The excretion of lactate in human sweat stimulated by iontophoresis of pilocarpine: studies with different regions, doses and courses
24. Correlation between sweat glucose and blood glucose in subjects with diabetes10.1089/dia.2011.0262 ↗
25. Autonomous sweat extraction and analysis applied to cystic fibrosis and glucose monitoring using a fully integrated wearable platform10.1073/pnas.1701740114 ↗
26. Lactate in human sweat: a critical review of research to the present day10.1007/s12576-012-0213-z ↗
27. Criteria for oral glucose tolerance test in pregnancy
28. Noninvasive diabetes monitoring through continuous analysis of sweat using flow-through glucose biosensor10.1021/acs.analchem.8b05928 ↗
29. Relationship between sweat and blood lactate levels during exhaustive physical exercise10.1002/celc.201901703 ↗
30. Relationship between lactate concentrations in active muscle sweat and whole blood10.1007/s10517-010-1075-0 ↗
31. Formulation and stability of a novel artificial human sweat under conditions of storage and use10.1016/j.tiv.2010.06.016 ↗
32. Glass-metal composite electrodes10.1021/ac60335a025 ↗
33. Advances of Prussian blue and its analogues in (bio)sensors10.1016/j.coelec.2017.07.006 ↗
34. Transition metal hexacyanoferrates in electrocatalysis of H2O2 reduction: an exclusive property of Prussian Blue10.1021/ac500595v ↗
35. Catalytically synthesized prussian blue nanoparticles defeating natural enzyme peroxidase10.1021/jacs.8b05223 ↗
36. Vokhmyanina · 2020
37. Sol-gel immobilization of lactate oxidase from organic solvent: toward the advanced lactate biosensor10.1021/ac9027615 ↗
38. Noninvasive hypoxia monitor based on gene-free engineering of lactate oxidase for analysis of undiluted sweat10.1021/ac501547u ↗
39. Electrochemical tattoo biosensors for real-time noninvasive lactate monitoring in human perspiration10.1021/ac401573r ↗
40. Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis10.1038/nature16521 ↗
41. Wearable/disposable sweat-based glucose monitoring device with multistage transdermal drug delivery module10.1126/sciadv.1601314 ↗
42. Battery-free, skin-interfaced microfluidic/electronic systems for simultaneous electrochemical, colorimetric, and volumetric analysis of sweat10.1126/sciadv.aav3294 ↗
43. Integrated textile sensor patch for real-time and multiplex sweat analysis10.1126/sciadv.aax0649 ↗
44. Microfluidic chip-based wearable colorimetric sensor for simple and facile detection of sweat glucose10.1021/acs.analchem.9b03110 ↗
45. A wearable chemical-electrophysiological hybrid biosensing system for real-time health and fitness monitoring10.1038/ncomms11650 ↗
46. A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat10.1126/scitranslmed.aaf2593 ↗
47. Wearable sensor system for detection of lactate in sweat10.1038/s41598-018-33565-x ↗
48. A wearable biosensor based on bienzyme gel-membrane for sweat lactate monitoring by mounting on eyeglasses10.1166/jnn.2020.16952 ↗
49. Noiseless performance of Prussian Blue based (bio)sensors through power generation10.1021/acs.analchem.7b01142 ↗