journal article·2018-12

Concurrent measurements of neurochemical and electrophysiological activity with microelectrode arrays: New perspectives for constant potential amperometry

Ana Ledo, Cátia F. Lourenço, João Laranjinha, Greg A. Gerhardt, Rui M. Barbosa

Publisher page

Abstract

Our current understanding of neurotransmission and neuromodulation stands to gain from concurrent electrochemical and electrophysiological measurements, which have been attempted since the introduction of in vivo electrochemical techniques. Dual in vivo recordings have evolved from parallel approaches using two distinct microelectrodes towards serial strategies encompassing “time-sharing” between two independent recording systems while using a single microelectrode. More recently, fast sampling amperometry has been demonstrated to allow concurrent measurement of rapid neurochemical and electrophysiological events using a single sensor and recording system. This is supported by the fact that the high-frequency component of an amperometric recording (>1 Hz) resembles the local field potential while the low frequency component (<1 Hz) reflects the electrochemical signal resulting from the oxidation or reduction of electroactive species present in the milieu. This opens new avenues for constant potential amperometry, widening the application of this seamless electrochemical technique.
Source: expertdata · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Neuroscience and Neural Engineering · Electrochemical Analysis and Applications · EEG and Brain-Computer Interfaces

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (60)

Show source-provided references
1. Nanotools for neuroscience and brain activity mapping10.1021/nn4012847 ↗
2. Nonsynaptic communication in the central nervous system10.1016/j.neuint.2003.11.016 ↗
3. Microfabricated probes for studying brain chemistry: a review10.1002/cphc.201701180 ↗
4. Emerging trends in in vivo neurochemical monitoring by microdialysis10.1016/j.cbpa.2013.06.012 ↗
5. Histological studies of the effects of chronic implantation of ceramic-based microelectrode arrays and microdialysis probes in rat prefrontal cortex10.1016/j.brainres.2009.06.084 ↗
6. Electrochemical Analysis of Neurotransmitters10.1146/annurev-anchem-071114-040426 ↗
7. Self-referencing ceramic-based multisite microelectrodes for the detection and elimination of interferences from the measurement of L-glutamate and other analytes10.1021/ac0010429 ↗
8. State-of-the-art MEMS and microsystem tools for brain research10.1038/micronano.2016.66 ↗
9. Progress towards biocompatible intracortical microelectrodes for neural interfacing applications10.1088/1741-2560/12/1/011001 ↗
10. Real-time in vivo neurotransmitter measurements using enzyme-based ceramic microelectrode arrays: what have we learned about glutamate signaling
11. An in vitro model to evaluate cell adhesion to metals used in implantation shows significant differences between palladium and gold or platinum10.1016/j.cellbi.2004.04.009 ↗
12. Responses of fibroblasts and glial cells to nanostructured platinum surfaces10.1088/0957-4484/20/38/385103 ↗
13. Impedance characterization, degradation, and in vitro biocompatibility for platinum electrodes on BioMEMS10.1007/s10544-014-9909-6 ↗
14. Hydrogen peroxide electrochemistry on platinum: towards understanding the oxygen reduction reaction mechanism10.1039/c2cp40616k ↗
15. Methodology for rapid measures of glutamate release in rat brain slices using ceramic-based microelectrode arrays: Basic characterization and drug pharmacology10.1016/j.brainres.2011.05.025 ↗
16. Aberrant glutamate signaling in the prefrontal cortex and striatum of the spontaneously hypertensive rat model of attention-deficit/hyperactivity disorder10.1007/s00213-014-3479-4 ↗
17. Chronic Methylphenidate Alters Tonic and Phasic Glutamate Signaling in the Frontal Cortex of a Freely-Moving Rat Model of ADHD
18. Prefrontal cortical recordings with biomorphic MEAs reveal complex columnar-laminar microcircuits for BCI/BMI implementation10.1016/j.jneumeth.2014.05.029 ↗
19. Conformal ceramic electrodes that record glutamate release and corresponding neural activity in primate prefrontal cortex
20. Microelectrode array biosensor for high-resolution measurements of extracellular glucose in the brain10.1016/j.snb.2016.06.083 ↗
21. L-lactate measures in brain tissue with ceramic-based multisite microelectrodes10.1016/j.bios.2004.07.003 ↗
22. Neurometabolic and electrophysiological changes during cortical spreading depolarization: multimodal approach based on a lactate-glucose dual microbiosensor arrays10.1038/s41598-017-07119-6 ↗
23. Ceramic-based multisite microelectrode arrays for simultaneous measures of choline and acetylcholine in CNS10.1016/j.bios.2007.12.013 ↗
24. Ceramic-based multisite platinum microelectrode arrays: morphological characteristics and electrochemical performance for extracellular oxygen measurements in brain tissue10.1021/acs.analchem.6b03772 ↗
25. Combined in vivo amperometric oximetry and electrophysiology in a single sensor: A tool for epilepsy research10.1021/acs.analchem.7b03452 ↗
26. Ceramic-based microelectrode neuronal recordings in the rat and monkey
27. Ceramic-based multisite electrode arrays for chronic single-neuron recording10.1109/TBME.2003.821037 ↗
28. Silicon wafer-based platinum microelectrode array biosensor for near real-time measurement of glutamate in Vivo10.3390/s8085023 ↗
29. Electrochemically deposited iridium oxide reference electrode integrated with an electroenzymatic glutamate sensor on a multi-electrode arraymicroprobe10.1016/j.bios.2012.10.061 ↗
30. Subcellular probes for neurochemical recording from multiple brain sites10.1039/C6LC01398H ↗
31. Chronic in vivo stability assessment of carbon fiber microelectrode arrays10.1088/1741-2560/13/6/066002 ↗
32. Chronoamperometry in vivo: does it interfere with spontaneous neuronal activity in the brain?10.1016/0165-0270(83)90077-8 ↗
33. Platform to enable combined measurement of dopamine and neural activity10.1021/acs.analchem.6b03642 ↗
34. A multi-site array for combined local electrochemistry and electrophysiology in the non-human primate brain10.1016/j.jneumeth.2015.07.009 ↗
35. A silicon based implantable microelectrode array for electrophysiological and dopamine recording from cortex to striatum in the non-human primate brain10.1016/j.bios.2016.04.087 ↗
36. Real-time simultaneous recording of electrophysiological activities and dopamine overflow in the deep brain nuclei of a non-human primate with Parkinson's disease using nano-based microelectrode arrays10.1038/micronano.2017.70 ↗
37. An integrated system for synchronous detection of neuron spikes and dopamine activities in the striatum of Parkinson monkey brain10.1016/j.jneumeth.2018.04.015 ↗
38. Neural probes for concurrent detection of neurochemical and electrophysiological signals in vivo
39. Implantable microelectrode arrays for simultaneous electrophysiological and neurochemical recordings10.1016/j.jneumeth.2008.06.036 ↗
40. An implantable microelectrode array for simultaneous L-glutamate and electrophysiological recordings in vivo10.1038/micronano.2015.2 ↗
41. Simultaneous recording of brain extracellular glucose, spike and local field potential in real time using an implantable microelectrode array with nano-materials10.1088/0957-4484/27/11/114001 ↗
42. Single probe for real-time simultaneous monitoring of neurochemistry and direct-current electrocorticography10.1016/j.bios.2015.09.021 ↗
43. Simultaneous “real-time” electrochemical and electrophysiological recording in brain slices with a single carbon-fibre microelectrode10.1016/0165-0270(93)90035-P ↗
44. Simultaneous dopamine and single-unit recordings reveal accumbens GABAergic responses: Implications for intracranial self-stimulation10.1073/pnas.0509607102 ↗
45. Effects of Glutamate Receptor Activation on Local Oxygen Changes10.1021/acschemneuro.7b00088 ↗
46. An implantable multimodal sensor for oxygen, neurotransmitters, and electrophysiology during spreading depolarization in the deep brain10.1039/C7AN00508C ↗
47. Instrumentation for fast-scan cyclic voltammetry combined with electrophysiology for behavioral experiments in freely moving animals10.1063/1.3610651 ↗
48. Acquiring local field potential information from amperometric neurochemical recordings10.1016/j.jneumeth.2009.01.023 ↗
49. Spatiotemporal coupling between hippocampal acetylcholine release and theta oscillations In Vivo10.1523/JNEUROSCI.1144-10.2010 ↗
50. Reconstruction of field excitatory post-synaptic potentials in the dentate gyrus from amperometric biosensor signals10.1016/j.jneumeth.2012.01.013 ↗
51. Combined electrochemical and electrophysiological studies of monoamine overflow in rat hippocampal slices10.1016/0006-8993(90)90966-F ↗
52. Simultaneous electrochemical and unit recording measurements: characterization of the effects of d-amphetamine and ascorbic acid on neostriatal neurons10.1016/0006-8993(83)91288-X ↗
53. Dopaminergic neurons: simultaneous measurements of dopamine release and single-unit activity during stimulation of the medial forebrain bundle10.1016/0006-8993(87)90968-1 ↗
54. Frontal cortical afferents facilitate striatal nitric oxide transmission in vivo via a NMDA receptor and neuronal NOS-dependent mechanism10.1111/j.1471-4159.2007.04811.x ↗
55. Expanding neurochemical investigations with multi-modal recording: simultaneous fast-scan cyclic voltammetry, iontophoresis, and patch clamp measurements10.1039/C6AN00933F ↗
56. Controlled iontophoresis coupled with fast-scan cyclic voltammetry/ electrophysiology in awake, freely moving animals10.1021/cn400031v ↗
57. Electrically-evoked release of norepinephrine in the rat cerebellum: an in vivo electrochemical and electrophysiological study10.1016/0006-8993(91)90782-Q ↗
58. Simultaneous measurement of cholinergic tone and neuronal network dynamics in vivo in the rat brain using a novel choline oxidase based electrochemical biosensor10.1016/j.bios.2015.02.003 ↗
59. In-Vitro Real-Time Coupled Electrophysiological and Electrochemical Signals Detection with Glassy Carbon Microelectrodes10.1149/2.0181705jes ↗
60. The effect of NMDA-R antagonism on simultaneously acquired local field potentials and tissue oxygen levels in the brains of freely-moving rats10.1016/j.neuropharm.2017.01.006 ↗