Reagentless and reusable electrochemical affinity biosensors for near real-time and/or continuous operation. Advances and prospects
Source abstract
Abstract
Abstract Nowadays, there is increasing demand to overcome the major constraints involved in cumbersome and protracted procedures used in conventional laboratory methods for molecular detection and develop methodologies suitable to near real-time, continuous, and direct monitoring of the target analyte in the analyzed sample at decentralized settings. In this context, biosensors using electrochemistry as transduction technique are particularly attractive to monitor binding-induced changes in the rigidity of a redox-tagged nucleic acid or peptide-switching probes (switch-based biosensors) or a capture antibody attached to an interrogating electrode. Sensors based on biomolecular switches, DNAs, aptamers, and peptides that reversibly shift between two or more conformations (or conformational ensembles) in response to the binding of a specific target ligand have been applied to the determination of a wide range of relevant analytes (nucleic acids, proteins, small molecules, and ions) and are rapid (responding in minutes), sensitive, reagentless, easily reusable, and less prone to fouling issues. They are capable to report in near real time the target binding event without any subsequent processing step, directly in challenging samples or continuously in flowing samples, and even in vivo using affordable and miniaturization-compatible instrumentation. Only a few redox-labeled capture antibody–based immunosensing strategies have been reported to date for the reagentless and continuous electrochemical determination of relevant analytes.
Source: openaire · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Advanced biosensing and bioanalysis techniques · Electrochemical Analysis and Applications · Biosensors and Analytical Detection
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (42)
Show source-provided references
1. Electrochemical DNA-based sensors for molecular quality control: continuous, real-time melamine detection in flowing whole milk10.1021/acs.analchem.8b01993 ↗
2. Switch-based biosensors: a new approach towards real-time, in vivo molecular detection10.1016/j.tibtech.2010.10.005 ↗
3. A modular, DNA-based beacon for single-step fluorescence detection of antibodies and other proteins10.1002/anie.201505179 ↗
4. Real-time measurement of small molecules directly in awake, ambulatory animals10.1073/pnas.1613458114 ↗
5. Electrochemical aptamer-based sensors for rapid point-of-use monitoring of the mycotoxin ochratoxin A directly in a food stream10.3390/molecules23040912 ↗
6. Construction of electrochemical flow immunoassay system using capillary columns and ferrocene conjugated immunoglobulin G for detection of human chorionic gonadotrophin10.1016/S0956-5663(01)00228-7 ↗
7. Amperometric micro-immunosensor for the detection of tumor biomarker10.1016/j.bios.2009.05.002 ↗
8. Biosensors for real-time in vivo measurements10.1016/j.bios.2004.12.003 ↗
9. Label-free electronic detection of thrombin in blood serum by using an aptamer-based sensor10.1002/anie.200500989 ↗
10. Monitoring rapid chemical communication in the brain10.1021/cr068081q ↗
11. Chapter Twenty - in vivo real-time measurement of nitric oxide in anesthetized rat brain10.1016/S0076-6879(08)01220-2 ↗
12. An electrochemical peptide-based biosensing platform for HIV detection10.1039/B919070H ↗
13. Advances in structure-switching aptasensing towards real time detection of cytokines10.1016/j.trac.2018.03.002 ↗
14. Folding-based electrochemical biosensors: the case for responsive nucleic acid architectures10.1021/ar900165x ↗
15. Reagentless, structure-switching, electrochemical aptamer-based sensors10.1146/annurev-anchem-071015-041446 ↗
16. Incorporation of extra amino acids in peptide recognition probe to improve specificity and selectivity of an electrochemical peptide based sensor10.1016/j.aca.2015.05.037 ↗
17. DNA-PEG-DNA Triblock macromolecules for reagentless DNA detection10.1021/ja046634d ↗
18. Label-free electrochemical detection of DNA in blood serum via target-induced resolution of an electrode-bound DNA pseudoknot10.1021/ja074218y ↗
19. Aptamer conformational switch as sensitive electrochemical biosensor for potassium ion recognition10.1039/b606804a ↗
20. Development of an electrochemical insulin sensor based on the insulin-linked polymorphic region10.1016/j.bios.2012.10.046 ↗
21. Folding-upon-binding and signal-on electrochemical DNA sensor with high affinity and specificity10.1021/ac501418g ↗
22. Single-step electronic detection of femtomolar DNA by target-induced strand displacement in an electrode-bound duplex10.1073/pnas.0607693103 ↗
23. Towards the development of a sensitive and selective electrochemical aptamer-based ampicillin sensor10.1016/j.snb.2017.11.193 ↗
24. E-DNA sensors for convenient, label-free electrochemical detection of hybridization10.1007/s00604-008-0015-4 ↗
25. An electrochemical peptide-based Ara h 2 antibody sensor fabricated on a nickel(II)-nitriloacetic acid self-assembled monolayer using a His-tagged peptide10.1016/j.aca.2014.04.033 ↗
26. New architecture for reagentless, protein-based electrochemical biosensors10.1021/jacs.7b05953 ↗
27. Tunable signal-off and signal-on electrochemical Cisplatin sensor10.1021/acs.analchem.7b02353 ↗
28. Characterization of an electrochemical mercury sensor using alternating current, cyclic, square wave and differential pulse voltammetry10.1016/j.aca.2013.12.005 ↗
29. Fabrication of electrochemical-DNA biosensors for the reagentless detection of nucleic acids, proteins and small molecules
30. Preparation of electrode-immobilized, redox-modified oligonucleotides for electrochemical DNA and aptamer-based sensing10.1038/nprot.2007.413 ↗
31. Design of DNA nanostructure-based interfacial probes for the electrochemical detection of nucleic acids directly in whole blood10.1039/C7SC04663D ↗
32. Aptamer-based biosensors for biomedical diagnostics10.1039/c4an00132j ↗
33. Comparison of mannose, ethylene glycol, and methoxy-terminated diluents on specificity and selectivity of electrochemical peptide-based sensors10.1021/acs.analchem.5b01759 ↗
34. A regenerative electrochemical sensor based on oligonucleotide for the selective determination of mercury(II)10.1039/b908457f ↗
35. Wash-free, electrochemical platform for the quantitative, multiplexed detection of specific antibodies10.1021/ac202757c ↗
36. Real-time, aptamer-based tracking of circulating therapeutic agents in living animals10.1126/scitranslmed.3007095 ↗
37. Detecting multiple cell-secreted cytokines from the same aptamer-functionalized electrode10.1016/j.bios.2014.08.034 ↗
38. Continuous, real-time monitoring of cocaine in undiluted blood serum via a microfluidic, electrochemical aptamer-based sensor10.1021/ja806531z ↗
39. Facile construction of a highly sensitive DNA biosensor by in-situ assembly of electro-active tags on hairpin-structured probe fragment10.1038/srep22441 ↗
40. Effects of redox label location on the performance of an electrochemical aptamer-based tumor necrosis factor-alpha sensor10.1016/j.talanta.2018.07.055 ↗
41. An electronic, aptamer-based small-molecule sensor for the rapid, label-free detection of cocaine in adulterated samples and biological Fluids10.1021/ja056957p ↗
42. Comparison of the signaling and stability of electrochemical DNA sensors fabricated from 6- or 11-carbon self-assembled monolayers10.1021/la0611817 ↗