journal article·2024-08Open access

Towards continuous potentiometric enzymatic biosensors

Xinxin Xiao, Jens Ulstrup

Abstract

Self-management of health and disease control using implantable biosensors is presently evolving strongly. Implantable biosensors require high selectivity and sensitivity, robust stability, temporal resolution, and device miniaturization. Electrochemical enzymatic biosensors that utilize specifically selective enzymes to convert the concentration of biomarker metabolites into electrochemical signals hold great promise to meet these criteria. As for electrochemical enzyme biosensors in continuous glucose monitoring, which have enjoyed great commercial success, amperometric biosensors have so far dominated enzymatic biosensor research and development. Potentiometric enzymatic biosensor research is, however, emerging with increasing strength, in particular due to greater promise for miniaturization. This minireview focuses on how to empower potentiometric enzymatic biosensors with high temporal resolution for continuous in situ monitoring of metabolites using the innovative non-equilibrium approach.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Electrochemical sensors and biosensors · Analytical Chemistry and Sensors · Electrochemical Analysis and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (54)

Show source-provided references
1. Electrochemical glucose biosensors10.1021/cr068123a ↗
2. Electrochemical glucose sensors and their applications in diabetes management10.1021/cr068069y ↗
3. Electrochemical sensing in contact lenses10.1002/elan.202100342 ↗
4. Electrochemical biosensors10.1021/ac00142a720 ↗
5. Capacitance-based biosensor for the measurement of total loss of L-amino acids in human serum during hemodialysis10.1021/acssensors.2c01342 ↗
6. Effect of enzyme-matrix composition on potentiometric response to glucose using glucose oxidase immobilized on platinum10.1016/0167-4838(83)90022-5 ↗
7. Immobilized glucose oxidase in the potentiometric detection of glucose10.1007/BF02798377 ↗
8. Glucose oxidase immobilized electrode for potentiometric estimation of glucose10.1016/0956-5663(91)87019-8 ↗
9. Enzyme chronopotentiometry10.1002/elan.1140060703 ↗
10. The direct use of enzymatic biofuel cells as functional bioelectronics10.1016/j.esci.2021.12.005 ↗
11. Understanding molecular and electrochemical charge transfer: theory and computations10.1039/D2CS00006G ↗
12. Direct electrochemical enzyme electron transfer on electrodes modified by self-assembled molecular monolayers10.3390/catal10121458 ↗
13. Versatile potentiometric metabolite sensing without dioxygen interference10.1016/j.bios.2021.113888 ↗
14. Review—in vivo electrochemical measurements of norepinephrine in the brain: current status and remaining challenges10.1149/2.0091812jes ↗
15. Challenges and perspectives in continuous glucose monitoring10.1039/C8CC01678J ↗
16. Consolidated biocomposite membrane technology for production of potentiometric biosensors10.1016/S0925-4005(99)00262-2 ↗
17. Recent advances in potentiometric biosensing10.1016/j.coelec.2021.100735 ↗
18. Potentiometric biosensing of ascorbic acid, uric acid, and cysteine in microliter volumes using miniaturized nanoporous gold electrodes10.3390/bios11010010 ↗
19. Design and preparation of open circuit potential biosensor for in vitro and in vivo glucose monitoring10.1007/s00216-016-9982-1 ↗
20. Potentiometric bioimaging with a large-scale integration (LSI)-based electrochemical device for detection of enzyme activity10.1016/j.bios.2015.10.021 ↗
21. Modulating the mixed potential for developing biosensors: direct potentiometric determination of glucose in whole, undiluted blood10.1016/j.bios.2020.112302 ↗
22. Oxidase-loaded hydrogels for versatile potentiometric metabolite sensing10.1016/j.bios.2021.112997 ↗
23. The economic cost of brain disorders in Europe10.1111/j.1468-1331.2011.03590.x ↗
24. Implantable (Bio) sensors as new tools for wireless monitoring of brain neurochemistry in real time10.5497/wjp.v3.i1.1 ↗
25. Monitoring rapid chemical communication in the brain10.1021/cr068081q ↗
26. Ultrafast glutamate biosensor recordings in brain slices reveal complex single exocytosis transients10.1021/acschemneuro.8b00624 ↗
27. Galvanic redox potentiometry for self-driven in vivo measurement of neurochemical dynamics at open-circuit potential10.1021/acs.analchem.8b03854 ↗
28. Stability enhancement of galvanic redox potentiometry by optimizing the redox couple in counterpart Poles10.1021/acs.analchem.3c00110 ↗
29. Tackling the challenges of enzymatic (Bio)Fuel cells10.1021/acs.chemrev.9b00115 ↗
30. Self-powered enzyme-based biosensors10.1021/ja0167102 ↗
31. Mechanistic characterization of an oxygen reduction reaction-driven, fully enzymatic and self-calibrating pH biosensor based on wired bilirubin oxidase10.1016/j.snb.2022.132054 ↗
32. A novel wireless glucose sensor employing direct electron transfer principle based enzyme fuel cell10.1016/j.bios.2006.11.004 ↗
33. Real-time glucose monitoring system containing enzymatic sensor and enzymatic reference electrodes10.1016/j.bios.2020.112338 ↗
34. Self-charging electrochemical biocapacitor10.1002/celc.201300142 ↗
35. Supercapacitor/biofuel cell hybrids based on wired enzymes on carbon nanotube matrices: autonomous reloading after high power pulses in neutral buffered glucose solutions10.1039/C3EE43986K ↗
36. Hybrid glucose/O2 biobattery and supercapacitor utilizing a pseudocapacitive dimethylferrocene redox polymer at the bioanode10.1021/acsenergylett.6b00225 ↗
37. Pankratov · Angew Chem Int Ed · 2016 · 55 · 1543410.1002/anie.201607144 ↗
38. A symmetric supercapacitor/biofuel cell hybrid device based on enzyme-modified nanoporous gold: an autonomous pulse generator10.1016/j.bios.2016.11.012 ↗
39. A quasi-solid-state and self-powered biosupercapacitor based on flexible nanoporous gold electrodes10.1039/C8CC02555J ↗
40. An oxygen-independent and membrane-less glucose biobattery/supercapacitor hybrid device10.1016/j.bios.2017.07.023 ↗
41. Method for low nanomolar concentration analyte sensing using electrochemical enzymatic biosensors10.1021/acs.analchem.7b04075 ↗
42. BioCapacitor—a novel category of biosensor10.1016/j.bios.2008.09.014 ↗
43. BioCapacitor: a novel principle for biosensors10.1016/j.bios.2015.07.065 ↗
44. A self-powered minimalistic glucometer: a lean approach to sustainable single-use point-of-care devices10.1002/admt.202001051 ↗
45. Modern potentiometric biosensing based on non-equilibrium measurement techniques10.1002/chem.202302647 ↗
46. Enhancing ion-selective polymeric membrane electrodes by instrumental control10.1016/j.trac.2013.09.014 ↗
47. Pulstrodes: triple pulse control of potentiometric sensors10.1021/ja047728q ↗
48. Development of a third-generation glucose sensor based on the open circuit potential for continuous glucose monitoring10.1016/j.bios.2018.09.099 ↗
49. Transient potentiometry based d-serine sensor using engineered d-amino acid oxidase showing quasi-direct electron transfer property10.1016/j.bios.2021.113927 ↗
50. The development of micro–sized enzyme sensor based on direct electron transfer type open circuit potential sensing principle10.1016/j.electacta.2022.140798 ↗
51. Enzyme kinetics via open circuit potentiometry10.1021/acs.analchem.9b04972 ↗
52. Catalytic biosensors operating under quasi-equilibrium conditions for mitigating the changes in substrate diffusion10.1002/anie.202211559 ↗
53. Glucose oxidase—hexokinase bienzyme electrode sensor for adenosine triphosphate10.1016/0003-2670(80)87043-7 ↗
54. An electrochemical NADH biosensor based on a nanoporous gold electrode modified with diaphorase and an osmium polymer