Continuous monitoring of biomolecular targets in vivo using DNA-based electrochemical sensors
Source abstract
Abstract
Real-time, continuous in vivo molecular monitoring is crucial for advancing biomedical research and clinical healthcare, yet traditional methods face significant limitations. Electrochemical DNA-based (eDNA) biosensors are emerging as a powerful and highly versatile platform to address these needs. This review highlights key advancements within the last three years in eDNA biosensors tailored for in vivo continuous monitoring, emphasizing strategies to overcome challenges in stability, selectivity, and reversibility. Specifically, we delve into core eDNA biosensor designs and their in vivo applications, such as therapeutic drug monitoring, pharmacokinetic studies, real-time tracking of disease and neurochemical biomarkers, and feedback-controlled drug delivery. Furthermore, we critically examine significant progress in developing calibration-free operational strategies and ongoing efforts to tackle challenges related to long-term stability, receptor responsiveness, and target selectivity. The continued evolution of these platforms and their integration with artificial intelligence, positions eDNA biosensors as transformative tools for future biomedical breakthroughs and precision healthcare. Highlights • eDNA sensors enable versatile real-time in vivo molecular monitoring. • Key eDNA platforms: EAB, DNA pendulum, and aptamer-FET biosensors. • In vivo eDNA sensors advance TDM and personalized drug therapy. • Calibration-free strategies simplify in vivo eDNA sensor operation. • Overcoming stability and selectivity is key for eDNA sensor translation.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Advanced biosensing and bioanalysis techniques · Biosensors and Analytical Detection · RNA and protein synthesis mechanisms
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (74)
Show source-provided references
1. Biomolecular sensors for advanced physiological monitoring10.1038/s44222-023-00067-z ↗
2. Conformational-switch biosensors as novel tools to support continuous, real-time molecular monitoring in lab-on-a-chip devices10.1039/D2LC00716A ↗
3. Molecular origins of long-term changes in a competitive continuous biosensor with single-molecule resolution10.1021/acssensors.4c00107 ↗
4. Review of noninvasive continuous glucose monitoring in diabetics10.1021/acssensors.3c01538 ↗
5. Closed-loop insulin delivery in suboptimally controlled type 1 diabetes: a multicentre, 12-week randomised trial10.1016/S0140-6736(18)31947-0 ↗
6. Real-time, in vivo molecular monitoring using electrochemical aptamer based sensors: opportunities and challenges10.1021/acssensors.2c01428 ↗
7. Biosensors for real-time in vivo measurements10.1016/j.bios.2004.12.003 ↗
8. In vivo biosensing: progress and perspectives10.1021/acssensors.6b00834 ↗
9. Phenylalanine monitoring via aptamer-field-effect transistor sensors10.1021/acssensors.9b01963 ↗
10. Real-time, seconds-resolved measurements of plasma methotrexate in situ in the living body10.1021/acssensors.2c01894 ↗
11. Seconds-resolved pharmacokinetic measurements of the chemotherapeutic irinotecan in situ in the living body10.1039/C9SC01495K ↗
12. An aptamer-based electrochemical sensor for the quantification of the malaria biomarker lactate dehydrogenase10.1016/j.bios.2025.117152 ↗
13. Reagentless biomolecular analysis using a molecular pendulum10.1038/s41557-021-00644-y ↗
14. Aptamers from cell-based selection for bioanalytical applications10.1021/cr300468w ↗
15. Nucleic acid-based wearable and implantable electrochemical sensors10.1039/D4CS00001C ↗
16. Switch-based biosensors: a new approach towards real-time, in vivo molecular detection10.1016/j.tibtech.2010.10.005 ↗
17. In vitro selection of aptamers and their applications10.1038/s43586-023-00238-7 ↗
18. Recognition and sensing of low-epitope targets via ternary complexes with oligonucleotides and synthetic receptors10.1038/nchem.2058 ↗
19. DNA-based scaffolds for sensing applications10.1021/acs.analchem.8b05009 ↗
20. E-DNA scaffold sensors and the reagentless, single-step, measurement of HIV-Diagnostic antibodies in human serum10.1038/s41378-019-0119-5 ↗
21. Reagentless, structure-switching, electrochemical aptamer-based sensors10.1146/annurev-anchem-071015-041446 ↗
22. Critical review—approaches for the electrochemical interrogation of DNA-based sensors: a critical review10.1149/2.0292003JES ↗
23. Real-time measurement of small molecules directly in awake, ambulatory animals10.1073/pnas.1613458114 ↗
24. Implantable aptamer–field-effect transistor neuroprobes for in vivo neurotransmitter monitoring10.1126/sciadv.abj7422 ↗
25. Aptamer–field-effect transistors overcome debye length limitations for small-molecule sensing10.1126/science.aao6750 ↗
26. Self-assembled monolayer transporters enable reagentless analysis of small molecule analytes10.1021/acssensors.4c00861 ↗
27. Active-reset protein sensors enable continuous in vivo monitoring of inflammation10.1126/science.adn2600 ↗
28. Nanobody receptors enable high-sensitivity monitoring of IL-6 using molecular pendulum bioanalysis10.1021/acs.analchem.4c06305 ↗
29. Continuous insulin monitoring using an antibody-protecting zwitterionic microneedle patch10.1038/s41551-025-01477-7 ↗
30. Wearable aptamer-field-effect transistor sensing system for noninvasive cortisol monitoring
31. Implantable aptamer-graphene microtransistors for real-time monitoring of neurochemical release in vivo10.1021/acs.nanolett.2c00289 ↗
32. Multiplexed monitoring of neurochemicals via electrografting-enabled site-selective functionalization of aptamers on field-effect transistors10.1021/acs.analchem.1c05531 ↗
33. An implantable, ultralow distortion bioelectronic interface integrating light-emitting diodes and graphene field-effect transistors10.1021/acsnano.5c04148 ↗
34. Biosensors and nanobiosensors for therapeutic drug and response monitoring10.1039/C5AN01861G ↗
35. High-precision control of plasma drug levels using feedback-controlled dosing10.1021/acsptsci.8b00033 ↗
36. Simultaneous, seconds-resolved doxorubicin measurements in the blood and subcutaneous interstitial fluid identify quantitative pharmacokinetic relationships between the two10.1021/acsptsci.5c00062 ↗
37. High-precision monitoring of and feedback control over drug concentrations in the brains of freely moving rats10.1126/sciadv.adg3254 ↗
38. A high-precision view of intercompartmental drug transport via simultaneous, seconds-resolved, in situ measurements in the vein and brain10.1111/bph.16471 ↗
39. Therapeutic drug distribution across the mouse brain is heterogeneous as revealed by in vivo, spatially resolved aptamer-based sensing10.1021/acsptsci.4c00579 ↗
40. Real-time monitoring of drug pharmacokinetics within tumor tissue in live animals10.1126/sciadv.abk2901 ↗
41. Feedback control over plasma drug concentrations achieves rapid and accurate control over solid-tissue drug concentrations10.1021/acsptsci.5c00142 ↗
42. Wearable microneedle-based electrochemical aptamer biosensing for precision dosing of drugs with narrow therapeutic windows10.1126/sciadv.abq4539 ↗
43. Closed-loop control of circulating drug levels in live animals10.1038/s41551-017-0070 ↗
44. Employing a redox reporter-modified self-assembly monolayer in electrochemical aptamer-based sensors to enable calibration-free measurements10.1021/acsabm.3c00001 ↗
45. Single voltammetric sweep calibration-free interrogation of electrochemical aptamer-based sensors employing continuous square wave voltammetry10.1021/acs.analchem.3c05920 ↗
46. High frequency, calibration-free molecular measurements in situ in the living body10.1039/C9SC04434E ↗
47. Calibration-free, seconds-resolved in vivo molecular measurements using fourier-transform impedance spectroscopy interrogation of electrochemical aptamer sensors10.1021/acssensors.3c00632 ↗
48. Dual-frequency, ratiometric approaches to EAB sensor interrogation support the calibration-free measurement of specific molecules in vivo10.1021/acssensors.4c00516 ↗
49. Dual-reporter drift correction to enhance the performance of electrochemical aptamer-based sensors in whole blood10.1021/jacs.6b08671 ↗
50. Dual-aptamer drift canceling techniques to improve long-term stability of real-time structure-switching aptasensors10.1021/acssensors.3c00509 ↗
51. Dual-chronoamperometry drift correction for electrochemical sensors10.1021/acssensors.5c02104 ↗
52. The challenge of long-term stability for nucleic acid-based electrochemical sensors
53. Elucidating the mechanisms underlying the signal drift of electrochemical aptamer-based sensors in whole blood10.1021/acssensors.1c01183 ↗
54. On the blood components contributing to the drift of electrochemical aptamer-based biosensors10.1021/acssensors.5c01267 ↗
55. Antifouling strategies for selective in vitro and in vivo sensing10.1021/acs.chemrev.9b00739 ↗
56. A biomimetic phosphatidylcholine-terminated monolayer greatly improves the in vivo performance of electrochemical aptamer-based sensors10.1002/anie.201700748 ↗
57. Anti-fouling polymer or peptide-modified electrochemical biosensors for improved biosensing in complex media
58. Implantable hydrogel-protective DNA aptamer-based sensor supports accurate, continuous electrochemical analysis of drugs at multiple sites in living rats10.1021/acsnano.3c06520 ↗
59. Combinatorial polyacrylamide hydrogels for preventing biofouling on implantable biosensors10.1002/adma.202109764 ↗
60. A biochemical sensor with continuous extended stability in vivo10.1038/s41551-025-01389-6 ↗
61. Week-long operation of electrochemical aptamer sensors: new insights into self-assembled monolayer degradation mechanisms and solutions for stability in serum at body temperature10.1021/acssensors.2c02403 ↗
62. Beyond the gold–thiol paradigm: exploring alternative interfaces for electrochemical nucleic acid-based sensing10.1021/acssensors.4c00331 ↗
63. The use of xenonucleic acids significantly reduces the in vivo drift of electrochemical aptamer-based sensors10.1002/anie.202316678 ↗
64. Nuclease-assisted selection of slow-off rate aptamers10.1126/sciadv.adl3426 ↗
65. Real-time, aptamer-based tracking of circulating therapeutic agents in living animals10.1126/scitranslmed.3007095 ↗
66. Tailoring electrode surface charge to achieve discrimination and quantification of chemically similar small molecules with electrochemical aptamers
67. Exploring the landscape of aptamers: from cross-reactive to selective to specific, high-affinity receptors for cocaine10.1021/jacsau.3c00781 ↗
68. A functional group–guided approach to aptamers for small molecules10.1126/science.abn9859 ↗
69. Zwitterionic DNA: enzymatic synthesis of hypermodified DNA bearing four different cationic substituents at all four nucleobases10.1093/nar/gkaf155 ↗
70. Label-free electronic detection of thrombin in blood serum by using an aptamer-based sensor10.1002/anie.200500989 ↗
71. Detection of SARS-CoV-2 viral particles using direct, reagent-free electrochemical sensing10.1021/jacs.0c10810 ↗
72. Flexible multiplexed In2O3 nanoribbon aptamer-field-effect transistors for biosensing10.1016/j.isci.2020.101469 ↗
73. Continuous molecular monitoring in the body via nucleic acid–based electrochemical sensors: the need for statistically-powered validation
74. Artificial intelligence-powered electronic skin10.1038/s42256-023-00760-z ↗