Shear bond strengths between different zirconia cores and veneering ceramics and their susceptibility to thermocycling
Source abstract
Abstract
Objectives The purpose of this study was to evaluate the shear bond strength between various commercial zirconia core and veneering ceramics, and to investigate the effect of thermocycling. Methods The Schmitz-Schulmeyer test method was used to evaluate the core-veneer shear bond strength (SBS) of three zirconia core ceramics (Cercon Base, Vita In-Ceram YZ Cubes, DC-Zirkon) and their manufacturer recommended veneering ceramics (Cercon Ceram S, Vita VM9, IPS e.max Ceram). A metal ceramic system (Degudent U94, Vita VM13) was used as a control group for the three all-ceramic test groups (n = 30 specimens/group). Half of each group (n = 15) was thermocycled (5-55 degrees C, 20,000 cycles). Subsequently, all specimens were subjected to shear force in a universal testing machine. Fractured specimens were evaluated microscopically to determine the failure mode. Results The initial mean SBS values in MPa+/-S.D. were 12.5+/-3.2 for Vita In-Ceram YZ Cubes/Vita VM9, 11.5+/-3.4 for DC-Zirkon/IPS e.max Ceram, and 9.4+/-3.2 for Cercon Base/Cercon Ceram S. After thermocycling mean SBS values of 11.5+/-1.7 MPa for DC-Zirkon/IPS e.max Ceram, 9.7+/-4.2 MPa for Vita In-Ceram YZ Cubes/Vita VM9, and 9.6+/-4.2 MPa for Cercon Base/Cercon Ceram S were observed. Neither the differences between the SBS values of the all-ceramic test groups nor the influence of thermocycling on all groups were statistically significant. Irrespective of thermocycling the metal ceramic control group (27.6+/-12.1 MPa, 26.4+/-13.4 MPa) exhibited significantly higher mean SBS than all three all-ceramic groups tested. The all-ceramic groups showed combined failure modes as cohesive in the veneering ceramic and adhesive at the interface, whereas the metal ceramic group showed predominately cohesive fractures. Significance The results indicated that the SBS between zirconia core and veneering ceramics was not affected by thermocycling. None of the zirconia core and veneering ceramics could attain the high bond strength values of the metal ceramic combination.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Anatomy and Medical Technology · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (47)
Show source-provided references
1. A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years10.1111/j.1600-0501.2004.01119.x ↗
2. Meta-analysis of fixed partial denture survival: prostheses and abutments10.1016/S0022-3913(98)70162-3 ↗
3. A meta-analysis of durability data on conventional fixed bridges10.1111/j.1600-0528.1994.tb00795.x ↗
4. Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature10.1016/j.prosdent.2004.09.015 ↗
5. Mechanical properties and short-term in vivo evaluation of yttrium-oxide-partially-stabilized zirconia10.1002/jbm.820230105 ↗
6. Structural reliability of alumina-, feldspar-, leucite-, mica- and zirconia-based ceramics10.1016/S0300-5712(00)00030-0 ↗
7. Reliability and strength of all-ceramic dental restorations fabricated by direct ceramic machining (DCM)
8. Clinical evaluation of zirconium oxide bridges in the posterior segments fabricated with the DCM system
9. [All-ceramic FPDs made of DC-Zirkon—a clinical concept with success?]
10. Cyclic fatigue in water of veneer-framework composites for all-ceramic dental bridges10.1016/j.dental.2006.01.011 ↗
11. Mechanical and fracture behavior of veneer-framework composites for all-ceramic dental bridges10.1016/j.dental.2005.12.009 ↗
12. All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study10.1111/j.1365-2842.2004.01437.x ↗
13. Prospective clinical study of zirconia posterior fixed partial dentures: 3-year follow up
14. The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study10.1016/j.prosdent.2006.08.010 ↗
15. Six-year follow-up of titanium and high-gold porcelain-fused-to-metal fixed partial dentures10.1046/j.1365-2842.1999.00373.x ↗
16. Long-term clinical study of porcelain-fused-to-gold restorations10.1016/0022-3913(84)90217-8 ↗
17. A 15-year clinical evaluation of fixed prosthodontics10.3109/00016359109041138 ↗
18. [Determination of the adhesion of dental metal-porcelain bonding systems]
19. ISO 9693. Metal-ceramic bond characterization (Schwickerath crack initiation test). Geneva, Switzerland: International Organization for Standardization; 1999.
20. Fracture toughness and hardness evaluation of three pressable all-ceramic dental materials10.1016/S0300-5712(03)00025-3 ↗
21. Shear strength of core–veneer interface in bi-layered ceramics10.1016/j.prosdent.2004.02.009 ↗
22. Bond strengths of veneering ceramics to reinforced ceramic core materials
23. Comparison of two bond strength testing methodologies for bilayered all-ceramics10.1016/j.dental.2006.05.004 ↗
24. Designs of bond strength tests for metal-ceramic complexes: review of the literature10.1016/S0022-3913(96)90244-9 ↗
25. Comparative evaluation of ceramic-metal bond tests using finite element stress analysis10.1177/00220345800590030901 ↗
26. Zirconia-TZP and alumina-advanced technologies for the manufacturing of single crowns
27. The relationship between oxide adherence and porcelain-metal bonding10.1177/00220345880670020801 ↗
28. Comparison of bond strength of a pressed ceramic fused to metal versus feldspathic porcelain fused to metal10.1111/j.1532-849X.2005.00052.x ↗
29. Stephan M. Beschichtungsverhalten von Verblendmaterialien auf Dentalkeramik. Tübingen: Diplomarbeit der Geowissenschaftlichen Fakultät; 1996.
30. Influence of thermal expansion mismatch and fatigue loading on phase changes in porcelain veneered Y-TZP zirconia discs10.1111/j.1365-2842.2006.01675.x ↗
31. Porcelain-metal thermal compatibility10.1177/00220345810600040801 ↗
32. Microtensile bond strength of different components of core veneered all-ceramic restorations10.1016/j.dental.2005.03.013 ↗
33. The effect of the leucite transformation on dental porcelain expansion10.1016/S0109-5641(86)80067-7 ↗
34. The effects of thermal mismatch and fabrication procedures on the deflection of layered all-ceramic discs10.1016/j.dental.2004.09.001 ↗
35. Metal ceramic compatibility: a review of the literature10.1016/0022-3913(90)90259-F ↗
36. Biomaterials Properties Online Database. University of Michigan. Quintessence Publishing 1996; www.lib.umich.edu/dentlib/Dental_tables/Thermcond.html.
37. Competing fracture modes in brittle materials subject to concentrated cyclic loading in liquid environments: Trilayer structures10.1557/jmr.2006.0056 ↗
38. Thermal shock resistance of core reinforced all-ceramic crown systems10.1002/jbm.820280208 ↗
39. Effects of initial temperature and tempering medium on thermal tempering of dental porcelains10.1177/00220345930720030201 ↗
40. Role of microstructure on contact damage and strength degradation of micaceous glass-ceramics10.1016/S0109-5641(98)00013-X ↗
41. Deep-penetrating conical cracks in brittle layers from hydraulic cyclic contact10.1002/jbm.b.30195 ↗
42. Comparative strength of metal-ceramic and metal-composite bonds after extended thermocycling10.1111/j.1365-2842.2004.01391.x ↗
43. Microtensile bond strength of different components of core veneered all-ceramic restorations. Part II: zirconia veneering ceramics10.1016/j.dental.2005.11.014 ↗
44. Fracture of porcelain-veneered structures in fatigue10.1177/154405910708600207 ↗
45. Flexural strength of a layered zirconia and porcelain dental all-ceramic system10.1016/j.prosdent.2005.05.007 ↗
46. Bond strength of porcelain to dental alloys—an evaluation of two test methods
47. [Effect of the treatments preceding porcelain baking on the strength of the ceramic-metal bond]