Effect of composite temperature on in vitro intrapulpal temperature rise
Source abstract
Abstract
Objectives To measure in vitro intrapulpal temperature when placing and restoring with either room-temperature or pre-heated (54 and 60 degrees C) composite. Methods A K-type thermocouple was placed in the pulpal chamber of an extracted, human bifurcated upper premolar which had a Class V preparation (1 mm remaining dentin thickness) on the facial surface. Tooth roots were immersed in a thermostatically controlled water bath and perfused with water at 1.25 microl/min to simulate physiological circulation in the pulp chamber. The thermocouple was connected to an analog-to-digital converter. The preparation was filled using composite either at room-temperature, or pre-heated to 54 or 60 degrees C with a commercial compule heater (Calset), using standard clinical procedures by one person while continuously monitoring intrapulpal temperature (n=5). Temperature rise over baseline values were determined at various stages during the restoration process: composite placement, contouring, prior to light-curing, and immediately after light-curing (20s, Optilux 501). At each measurement interval, intrapulpal temperature values were compared using ANOVA and the Tukey-Kramer post hoc test (alpha=0.05). Results Significant differences were found in intrapulpal temperature when comparing pre-heated and room-temperature composite treatments with respect to baseline among the stages of the restorative process. However, the extent of this increase with heated composite was only 0.8 degrees C. A 5 degrees C intrapulpal temperature rise was seen for all groups during photopolymerization. Significance Use of pre-heated composite only mildly increased intrapulpal temperature values when compared to composite delivered at room-temperature in an in vitro test environment. The largest temperature change occurred with application of the curing light.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Dental Research and COVID-19 · Dental Anxiety and Anesthesia Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (29)
Show source-provided references
1. Clinical benefits of pre-warmed composites
2. Thermally assisted polymerization of composite resins
3. Friedman J. Heating assembly for preheating dental materials. US patent 6,236,020; 2001.10.1088/1126-6708/2001/06/020 ↗
4. Composite film thickness at various temperatures
5. Monomer conversion of pre-heated composite10.1177/154405910508400716 ↗
6. The effect of cure rate on the mechanical properties of dental resins10.1016/S0109-5641(01)00010-0 ↗
7. The effects of light intensity, temperature, and comonomer composition on the polymerization behavior of dimethacrylate dental resins10.1177/00220345990780081301 ↗
8. Photoinitiated polymerization of a dimethacrylate oligomer. 1. Influence of photoinitiator concentration, temperature and light intensity10.1016/S0032-3861(97)00184-5 ↗
9. Photopolymerization of dental composite matrices10.1016/0142-9612(94)90273-9 ↗
10. Polymerization kinetics of pre-heated composite10.1177/154405910608500106 ↗
11. Use of near-IR to monitor the influence of external heating on dental composite photopolymerization10.1016/j.dental.2004.02.003 ↗
12. A pilot study of intraoral temperature changes10.1007/s007840000060 ↗
13. Clinically relevant issues related to pre-heating composites10.1111/j.1708-8240.2006.00046.x ↗
14. Pulp response to externally applied heat10.1016/0030-4220(65)90015-0 ↗
15. Sensory response to thermal stimulation in human teeth10.1016/S0099-2399(80)80216-0 ↗
16. Clinical and histological evaluation of thermal injury thresholds in human teeth: a preliminary study10.1111/j.1365-2842.1997.tb00278.x ↗
17. In vitro assessment of temperature change in the pulp chamber during cavity preparation10.1016/j.prosdent.2004.02.022 ↗
18. In vitro comparison of peak polymerization temperatures of 5 provisional restoration resins
19. Surface and intra-pulpal temperature rises during tooth bleaching: an in vitro study.
20. Intrapulpal temperature increases with temporary crown and bridge materials
21. Thermographic measurement of temperature change during resin composite polymerization in vivo10.1016/0300-5712(95)91149-H ↗
22. Comparison of halogen, plasma and LED curing units
23. Effect of high intensity vs. soft-start halogen irradiation on light-cured resin-based composites. Part I. Temperature rise and polymerization shrinkage.
24. Effect of irradiation type (LED or QTH) on photo-activated composite shrinkage strain kinetics, temperature rise, and hardness10.1034/j.1600-0722.2002.21359.x ↗
25. Influence of light intensity from different curing units upon composite temperature rise10.1111/j.1365-2842.2004.01418.x ↗
26. Measurement of thickness of remaining dentin after cavity preparation. Radiographic and direct methods
27. Microcirculation of the dental pulp in health and disease10.1016/S0099-2399(85)80219-3 ↗
28. Thermal effects on composite photopolymerization monitored by real-time NIR
29. Effects of the temperature of cooling water during high-speed and ultrahigh-speed tooth preparation10.1016/0022-3913(90)90228-5 ↗