Polymerization kinetics and impact of post polymerization on the Degree of Conversion of bulk-fill resin-composite at clinically relevant depth
Source abstract
Abstract
Objective Since bulk-fill (BF) resin composites should cure efficiently to a depth up to 4mm, the aim of the study was to determine the time-dependence of degree of conversion (DC) at that depth during 24h post-irradiation. Methods Eight representative BF resin composites were studied [x-tra base (XTB), Venus Bulk Fill (VBF), Tetric EvoCeram Bulk Fill (TECBF), Sonic Fill (SF), Filtek Bulk Fill (FBF), everX Posterior (eXP), Beautifil-Bulk Flowable (BBF), Beautifil-Bulk Restorative (BBR)]. Specimens were fabricated in white Delrin moulds of 4mm height and 5mm internal diameter directly on an attenuated total reflectance (ATR) accessory attachment of an (FTIR) spectrometer (Nicolet iS50, Thermo Fisher, Madison, USA). Upper specimen surfaces were irradiated in situ for 20 s with an LED curing unit (Elipar S10 with average tip irradiance of 1200 mW/cm(2)). Spectra from the lower surface were recorded continuously in real-time for 5 min and then at 30 and 60 min and 24h post irradiation. Results Mean ranges of DC4mm (%) of the materials at 4mm depth were 39-67; 48-75; 45-74; and 50-72 at 5, 30 and 60 min and 24h respectively. DCs for XTB, VBF, TECBF, FBF, BBR increased significantly 30 min after irradiation (p<0.05) and were not affected by subsequent time up to 24h (p>0.05). DC for SF was not affected by subsequent time after 5 min (p>0.05). For eXP and BBF, DC increased 24h after irradiation (p<0.05). The data were described by the superposition of two exponential functions characterising the gel phase (described by parameters a, b) and the glass phase (described by parameters c and d). Significance Post polymerization impact of bulk-fill composites is material dependent. Five materials exhibited their maximum DC4mm already 30 min after starting the irradiation while DC4mm for two materials optimized after 24h. BF materials were found to exhibit after 24h a DC between 50 and 72% at 4mm depth under the stated irradiation conditions.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Oral health in cancer treatment · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (38)
Show source-provided references
1. Degree of double bond conversion in light-cured composites10.1016/S0109-5641(87)80055-6 ↗
2. The effect of resin formulation on the degree of conversion and mechanical properties of dental restorative resins10.1002/jbm.820200111 ↗
3. Analysis and characterization of dental polymers
4. Volume contraction in photocured dental resins: the shrinkage-conversion relationship revisited10.1016/j.dental.2005.03.014 ↗
5. Remaining methacrylate groups in composite restorative materials10.3109/00016357809027569 ↗
6. Curing light performance and polymerization of composite restorative materials10.1016/0300-5712(92)90136-Z ↗
7. A survey of output intensity and potential for depth of cure among light-curing units in clinical use10.1016/S0300-5712(98)00052-9 ↗
8. Composite conversion and temperature rise using a conventional, plasma arc, and an experimental blue LED curing unit10.1046/j.1365-2842.2002.00866.x ↗
9. Degree of conversion and temperature rise during polymerization of composite resin samples with blue diodes10.1046/j.1365-2842.2001.00709.x ↗
10. Photopolymerization kinetics of methacrylate dental resins10.1021/ma021675k ↗
11. In vitro comparison of mechanical properties and degree of cure of bulk fill composites10.1007/s00784-012-0702-8 ↗
12. Polymerization contraction stress in light-cured packable composite resins10.1016/S0109-5641(00)00079-8 ↗
13. Degree of conversion of bulk-fill compared to conventional resin-composites at two time intervals10.1016/j.dental.2013.05.011 ↗
14. Curing profile of bulk-fill resin-based composites10.1016/j.jdent.2015.01.002 ↗
15. Photopolymerization kinetics of multifunctional monomers10.1016/S0079-6700(01)00004-1 ↗
16. Stability of radicals in cured composite materials10.1016/0109-5641(93)90064-W ↗
17. Post-irradiation polymerization of visible light-activated composite resin10.1177/00220345830620031201 ↗
18. Effect of temperature on post-cure polymerization of bulk-fill composites10.1016/j.jdent.2014.08.004 ↗
19. Effect of time and polymerization cycle on the degree of conversion of a resin composite10.2341/05-81 ↗
20. Correlation between hardness and degree of conversion during the setting reaction of unfilled dental restorative resins10.1016/S0109-5641(85)80058-0 ↗
21. Elution of leachable components from resin composites after plasma arc vs. standard or soft-start halogen light irradiation10.1016/S0300-5712(02)00022-2 ↗
22. Light intensity effects on resin-composite degree of conversion and shrinkage strain10.1016/S0109-5641(00)00020-8 ↗
23. Effect of light intensity and exposure duration on cure of resin composite
24. Factors affecting cure at depths within light-activated resin composites
25. Filler features and their effects on wear and degree of conversion of particulate dental resin composites10.1016/j.biomaterials.2005.01.026 ↗
26. Shrinkage behaviour of flowable resin-composites related to conversion and filler-fraction10.1016/j.jdent.2007.05.001 ↗
27. Effects of monomer ratios and highly radiopaque fillers on degree of conversion and shrinkage-strain of dental resin composites10.1016/j.dental.2009.06.009 ↗
28. Evaluation of the ion-releasing and recharging abilities of a resin-based fissure sealant containing S-PRG filler10.4012/dmj.2011-124 ↗
29. Effects of surface pre-reacted glass-ionomer fillers on mineral induction by phosphoprotein10.1016/j.jdent.2010.10.011 ↗
30. Detection of ions released from S-PRG fillers and their modulation effect10.4012/dmj.2010-015 ↗
31. Correlation of the degree of conversion with the amount of elutable substances in nano-hybrid dental composites10.1016/j.dental.2012.08.006 ↗
32. Degree of conversion of nano-hybrid resin-based composites with novel and conventional matrix formulation10.1007/s00784-012-0736-y ↗
33. Polymerization kinetic calculations in dental composites: a method comparison analysis10.1007/s00784-013-1128-7 ↗
34. After-polymerization of visible light activated resins: surface hardness vs. light source
35. Surface hardness development in light-cured composites10.1016/S0109-5641(87)80085-4 ↗
36. Post-irradiation polymerization of different anterior and posterior visible light-activated resin composites10.1016/0109-5641(92)90104-K ↗
37. Curing behaviour of high-viscosity bulk-fill composites10.1016/j.jdent.2014.05.012 ↗
38. Effect of chemical structure on degree of conversion in light-cured dimethacrylate-based dental resins10.1016/S0142-9612(01)00308-8 ↗