A fractographic study of clinically retrieved zirconia–ceramic and metal–ceramic fixed dental prostheses
Source abstract
Abstract
Objectives A recent 3-year randomized controlled trial (RCT) of tooth supported three- to five-unit zirconia-ceramic and metal-ceramic posterior fixed dental prostheses (FDPs) revealed that veneer chipping and fracture in zirconia-ceramic systems occurred more frequently than those in metal-ceramic systems [1]. This study seeks to elucidate the underlying mechanisms responsible for the fracture phenomena observed in this RCT using a descriptive fractographic analysis. Methods Vinyl-polysiloxane impressions of 12 zirconia-ceramic and 6 metal-ceramic FDPs with veneer fractures were taken from the patients at the end of a mean observation of 40.3±2.8 months. Epoxy replicas were produced from these impressions [1]. All replicas were gold coated, and inspected under the optical microscope and scanning electron microscope (SEM) for descriptive fractography. Results Among the 12 zirconia-ceramic FDPs, 2 had small chippings, 9 had large chippings, and 1 exhibited delamination. Out of 6 metal-ceramic FDPs, 5 had small chippings and 1 had large chipping. Descriptive fractographic analysis based on SEM observations revealed that fracture initiated from the wear facet at the occlusal surface in all cases, irrespective of the type of restoration. Significance Zirconia-ceramic and metal-ceramic FDPs all fractured from microcracks that emanated from occlusal wear facets. The relatively low fracture toughness and high residual tensile stress in porcelain veneer of zirconia restorations may contribute to the higher chipping rate and larger chip size in zirconia-ceramic FDPs relative to their metal-ceramic counterparts. The low veneer/core interfacial fracture energy of porcelain-veneered zirconia may result in the occurrence of delamination in zirconia-ceramic FDPs.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Reconstructive Facial Surgery Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (57)
Show source-provided references
1. Randomized controlled clinical trial of zirconia–ceramic and metal–ceramic posterior fixed dental prostheses: a 3-year follow-up
2. All-ceramic fixed partial dentures, part I: in vitro studies10.1111/j.1708-8240.2002.tb00518.x ↗
3. An up to 15-year longitudinal study of 515 metal–ceramic FPDs: part 1. Outcome
4. Clinical considerations for densely sintered alumina and zirconia restorations: part 1
5. Clinical considerations for densely sintered alumina and zirconia restorations: part 2
6. An overview of zirconia ceramics: basic properties and clinical applications10.1016/j.jdent.2007.07.008 ↗
7. Zirconia as a ceramic biomaterial10.1016/S0142-9612(98)00010-6 ↗
8. Effects of cementation surface modifications on fracture resistance of zirconia10.1016/j.dental.2015.01.013 ↗
9. Materials design in the performance of all-ceramic crowns10.1016/j.biomaterials.2003.09.050 ↗
10. The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic10.1016/S0109-5641(99)00070-6 ↗
11. A prospective study of implant-supported full-arch yttria-stabilized tetragonal zirconia polycrystal mandibular fixed dental prostheses: three-year results
12. A 3-year retrospective and clinical follow-up study of zirconia single crowns performed in a private practice10.1016/j.jdent.2009.06.002 ↗
13. All-ceramic inlay-retained fixed partial dentures: preliminary results from a clinical study10.1016/j.jdent.2008.04.017 ↗
14. Five-year clinical prospective evaluation of zirconia-based denzir 3-unit FPDs
15. A clinical evaluation of all-ceramic bridges placed in UK general dental practices: first-year results10.1038/sj.bdj.2008.937 ↗
16. Clinical behavior of zirconia-based fixed partial dentures made of dc-zirkon: 3-year results
17. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures
18. All-ceramic two- to five-unit implant-supported reconstructions. A randomized, prospective clinical trial
19. All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study10.1111/j.1365-2842.2004.01437.x ↗
20. Clinical evaluation of zirconia-based all-ceramic posterior bridges: two-year results
21. Fractographic analyses of three ceramic whole crown restoration failures10.1016/j.dental.2005.01.006 ↗
22. Fracture surface analysis of dental ceramics: clinically failed restorations
23. Failure analysis of ceramic clinical cases using qualitative fractography
24. Standard practice for fractography and characterization of fracture origins in advanced ceramics
25. Fractographic ceramic failure analysis using the replica technique10.1016/j.dental.2006.12.002 ↗
26. Reliability and strength of all-ceramic dental restorations fabricated by direct ceramic machining (DCM)
27. Quinn · 2007
28. 10-year clinical outcomes of fixed dental prostheses with zirconia frameworks
29. Longevity of fixed metal ceramic bridge prostheses: a clinical follow-up study10.1046/j.1365-2842.2002.00833.x ↗
30. A systematic review of the survival and complication rates of all-ceramic and metal–ceramic reconstructions after an observation period of at least 3 years. Part II: fixed dental prostheses10.1111/j.1600-0501.2007.01468.x ↗
31. Comparison of survival and complication rates of tooth-supported fixed dental prostheses (FDPs) and implant-supported FDPs and single crowns (SCs)10.1111/j.1600-0501.2007.01439.x ↗
32. Fatigue of dental ceramics10.1016/j.jdent.2013.10.007 ↗
33. Damage maps of veneered zirconia under simulated mastication10.1177/154405910808701210 ↗
34. Damage maps for layered ceramics under simulated mastication10.1177/154405910808700706 ↗
35. Development of an artificial oral environment for the testing of dental restoratives: bi-axial force and movement control10.1177/00220345830620010801 ↗
36. Sliding contact fracture of dental ceramics: principles and validation10.1016/j.actbio.2014.03.004 ↗
37. Mechanical characterization of dental ceramics by hertzian contacts10.1177/00220345980770041201 ↗
38. Competing damage modes in all-ceramic crowns: fatigue and lifetime10.4028/www.scientific.net/KEM.284-286.697 ↗
39. Competing fracture modes in brittle materials subject to concentrated cyclic loading in liquid environments: bilayer structures10.1557/JMR.2005.0335 ↗
40. Competing fracture modes in brittle materials subject to concentrated cyclic loading in liquid environments: monoliths10.1557/JMR.2005.0276 ↗
41. Competing fracture modes in brittle materials subject to concentrated cyclic loading in liquid environments: trilayer structures10.1557/jmr.2006.0056 ↗
42. Sliding contact fatigue damage in layered ceramic structures10.1177/154405910708601105 ↗
43. Fatigue damage in ceramic coatings from cyclic contact loading with a tangential component10.1111/j.1551-2916.2007.02009.x ↗
44. Deep-penetrating conical cracks in brittle layers from hydraulic cyclic contact10.1002/jbm.b.30195 ↗
45. Chipping resistance of graded zirconia ceramics for dental crowns10.1177/0022034511434356 ↗
46. Edge chipping and flexural resistance of monolithic ceramics10.1016/j.dental.2013.09.004 ↗
47. Reliability and failure modes of implant-supported zirconium-oxide fixed dental prostheses related to veneering techniques10.1016/j.jdent.2011.04.006 ↗
48. 2004
49. Fracture toughness of veneering ceramics for fused to metal (PFM) and zirconia dental restorative materials10.6028/jres.115.024 ↗
50. Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures10.1016/j.actbio.2008.12.016 ↗
51. Graded zirconia glass for resistance to veneer fracture10.1177/0022034510375289 ↗
52. Residual stresses in porcelain-veneered zirconia prostheses10.1016/j.dental.2012.04.019 ↗
53. On the interfacial fracture of porcelain/zirconia and graded zirconia dental structures10.1016/j.actbio.2014.04.016 ↗
54. Le Thanh · 2009
55. Influence of cooling rate on zirconia/veneer interfacial adhesion10.1016/j.actbio.2010.06.026 ↗
56. New approach for evaluating metal–porcelain interfacial bonding
57. Influence of the bonder on the adhesion of porcelain to machined titanium as determined by the strain energy release rate10.1016/j.dental.2006.06.022 ↗