journal article·2013-12

Clinical efficacy of composite versus ceramic inlays and onlays: A systematic review

Hélène Fron Chabouis, Violaine Smail Faugeron, Jean-Pierre Attal

Dental Materials· Volume 29· Issue 12
Publisher page

Abstract

Objectives Large tooth substance losses are frequent in posterior teeth because of primary caries or aging restorations. Inlays and onlays are often the minimal invasive solution in such cases, but the efficacy of the composite and ceramic materials used is unknown. We performed a systematic review of randomized controlled trials comparing the efficacy of composite and ceramic inlays or onlays. Data sources MEDLINE, Embase and the Cochrane Central Register of Controlled Trials were searched without any restriction on date or language, as were references of eligible studies and ClinicalTrials.gov. Study selection Eligible studies were randomized trials comparing the clinical efficacy of composite to ceramic inlays or onlays in adults with any clinical outcome for at least 6 months. From 172 records identified, we examined reports of 2 randomized controlled trials involving 138 inlays (no onlays evaluated) in 80 patients and exhibiting a high-risk of bias. Outcomes were clinical scores and major failures. The 3-year overall failure risk ratio was 2 [0.38-10.55] in favor of ceramic inlays although not statistically significant. The reported clinical scores (United States Public Health Services and Californian Dental Association) showed considerable heterogeneity between trials and could not be combined. Conclusions We have very limited evidence that ceramics perform better than composite material for inlays in the short term. However, this result may not be valid in the long term, and other trials are needed. Trials should follow Fédération dentaire internationale recommendations and enhance their methodology. Trials comparing composite and ceramic onlays are needed.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Dental Erosion and Treatment · Dental Health and Care Utilization

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (68)

Show source-provided references
1. Ceramics as biomaterials for dental restoration10.1586/17434440.5.6.729 ↗
2. Developing form, function, and natural aesthetics with laboratory-processed composite resin – Part I
3. Porcelain versus composite inlays/onlays: effects of mechanical loads on stress distribution, adhesion, and crown flexure
4. Effects of different ceramic and composite materials on stress distribution in inlay and onlay cavities: 3-D finite element analysis10.4012/dmj.28.661 ↗
5. Wear of ceramic inlays, their enamel antagonists, and luting cements10.1016/0022-3913(93)90192-Q ↗
6. Wear characteristics of current aesthetic dental restorative CAD/CAM materials: two-body wear, gloss retention, roughness and Martens hardness10.1016/j.jmbbm.2013.01.003 ↗
7. Clinical and semiquantitative marginal analysis of four tooth-coloured inlay systems at 3 years10.1016/0300-5712(95)98768-X ↗
8. Leucite-reinforced glass ceramic inlays after six years: wear of luting composites
9. Cytotoxicity of dental composites and their leached components
10. Correlation of clinical performance with ‘in vitro tests’ of restorative dental materials that use polymer-based matrices10.1016/j.dental.2011.08.594 ↗
11. Tooth wear and wear investigations in dentistry10.1111/j.1365-2842.2011.02257.x ↗
12. Marginal adaptation in vitro and clinical outcome of Class V restorations10.1016/j.dental.2008.11.004 ↗
13. Clinical evaluation of indirect composite restorations at baseline and 36 months after placement10.2341/09-133-C ↗
14. Leucite-reinforced glass ceramic inlays and onlays after six years: clinical behavior
15. Operator vs. material influence on clinical outcome of bonded ceramic inlays10.1016/j.dental.2009.02.002 ↗
16. Leucite-reinforced glass ceramic inlays and onlays after 12 years
17. [Preliminary clinical results of a prospective study of IPS e.max Press- and Cerec ProCAD-partial coverage crowns]
18. The clinical performance of CAD-CAM-generated ceramic inlays: a four-year study10.14219/jada.archive.1996.0408 ↗
19. Totally bonded ceramic inlays and onlays after eight years
20. Clinical performance of bonded leucite-reinforced glass ceramic inlays and onlays after eight years10.1016/j.dental.2004.03.009 ↗
21. Four-year clinical performance and marginal analysis of pressed glass ceramic inlays luted with ormocer restorative vs. conventional luting composite10.1016/j.jdent.2009.04.002 ↗
22. Time-and-motion study on class II copy-milled ceramic inlays10.1016/S0300-5712(00)00008-7 ↗
23. A prospective clinical study of ceromer inlays: results up to 53 months
24. Evaluation of fracture resistance of endodontically treated maxillary premolars, restored with ceromer or heat-pressed ceramic inlays and fixed with dual-resin cements10.1046/j.1365-2842.2003.01239.x ↗
25. Short-term clinical evaluation of inlay and onlay restorations made with a ceromer
26. Computer-aided direct ceramic restorations: a 10-year prospective clinical study of Cerec CAD/CAM inlays and onlays
27. An 8-year evaluation of sintered ceramic and glass ceramic inlays processed by the Cerec CAD/CAM system10.1034/j.1600-0722.2000.108003239.x ↗
28. Peumans · 2012
29. Longevity of 2328 chairside Cerec inlays and onlays
30. Longevity of ceramic inlays and onlays luted with a solely light-curing composite resin10.1016/j.jdent.2004.10.026 ↗
31. A 10-year prospective evaluation of CAD/CAM-manufactured (Cerec) ceramic inlays cemented with a chemically cured or dual-cured resin composite
32. IPS Empress inlays luted with a self-adhesive resin cement after 1 year
33. Resin-modified glass ionomer cement and self-cured resin composite luted ceramic inlays. A 5-year clinical evaluation10.1016/S0109-5641(03)00011-3 ↗
34. Fired ceramic inlays: a 6-year follow up10.1016/S0300-5712(97)00005-5 ↗
35. Clinical performance of pressed ceramic inlays luted with resin-modified glass ionomer and autopolymerizing resin composite cements10.1016/S0022-3913(99)70051-X ↗
36. Clinical evaluation of a heat-treated resin composite inlay: 3-year results
37. [A three-year clinical evaluation of ceramic optimized polymer posterior inlays]
38. Benefits and disadvantages of tooth-coloured alternatives to amalgam10.1016/S0300-5712(96)00066-8 ↗
39. Effect of three surface treatments on the adhesive properties of indirect composite restorations
40. Surface treatment protocols in the cementation process of ceramic and laboratory-processed composite restorations: a literature review10.1111/j.1708-8240.2005.tb00119.x ↗
41. Longevity of restorations in posterior teeth and reasons for failure
42. Buonocore Memorial Lecture. Review of the clinical survival of direct and indirect restorations in posterior teeth of the permanent dentition
43. Clinical efficacy of composite vs ceramic for inlays and onlays manufacturing: a systematic review. http://www.crd.york.ac.uk/PROSPERO/display_record.asp?ID=CRD42013003441.
44. Reprinting the classic article on USPHS evaluation methods for measuring the clinical research performance of restorative materials10.1007/s00784-005-0017-0 ↗
45. Hickel · J Adhes Dent · 2007 · 9 · 121
46. Assessing risk of bias in included studies
47. The Cochrane Collaboration's tool for assessing risk of bias in randomised trials10.1136/bmj.d5928 ↗
48. 2011
49. The clinical performance of CAD/CAM-generated composite inlays10.14219/jada.archive.2005.0116 ↗
50. A prospective clinical study of indirect and direct composite and ceramic inlays: ten-year results
51. Measuring inconsistency in meta-analyses10.1136/bmj.327.7414.557 ↗
52. FDI World Dental Federation: clinical criteria for the evaluation of direct and indirect restorations-update and clinical examples10.1007/s00784-010-0432-8 ↗
53. Mechanical properties of direct and indirect composites after storage for 24hours and 10 months
54. Effect of cyclic loading on marginal adaptation and bond strength in direct vs. indirect class II MO composite restorations10.2341/07-152 ↗
55. Effect of restorative technique and thermal/mechanical treatment on marginal adaptation and compressive strength of esthetic restorations10.2341/07-114 ↗
56. Randomization in clinical trials: stratification or minimization? The HERMES free simulation software
57. Marginal breakdown of fired ceramic inlays cemented with glass polyalkenoate (ionomer) cement or resin composite10.1016/0300-5712(94)90055-8 ↗
58. Three-year clinical evaluation of composite and ceramic inlays
59. A 2-year clinical study of composite and ceramic inlays10.1007/s007840000086 ↗
60. Simulated fatigue resistance of composite resin versus porcelain CAD/CAM overlay restorations on endodontically treated molars
61. Influence of overlay restorative materials and load cusps on the fatigue resistance of endodontically treated molars
62. Short-term results of IPS-Empress inlays and onlays10.1111/j.1532-849X.1996.tb00512.x ↗
63. Ceramic inlays (Cerec) cemented with either a dual-cured or a chemically cured composite resin luting agent. A 2-year clinical study10.3109/00016359509005995 ↗
64. IPS Empress inlays and onlays after four years – a clinical study10.1016/S0300-5712(98)00059-1 ↗
65. Ceramic inlays bonded with two adhesives after 4 years10.1016/j.dental.2005.02.013 ↗
66. A randomized 5-year clinical evaluation of 3 ceramic inlay systems
67. A 5-year clinical evaluation of ceramic inlays (Cerec) cemented with a dual-cured or chemically cured resin composite luting agent10.1080/000163598428428 ↗
68. Efficacy of composite versus ceramic inlays and onlays: study protocol for the CECOIA randomized controlled trial10.1186/1745-6215-14-278 ↗