Abstract
Objective To determine the potential effect of four different light curing units (LCUs) on the curing profile of two bulk fill resin-based composites (RBCs). Methods Four LCUs (Bluephase 20i, Celalux 3, Elipar DeepCure-S and Valo Grand) were used to light cure two RBCs (Filtek Bulk Fill Posterior Restorative and Tetric EvoCeram Bulk Fill). The effective tip diameter, radiant power, radiant emittance, emission spectrum and light beam profile of the LCUs were measured. Knoop microhardness was measured at the top and bottom surfaces of RBC specimens that were 12-mm in diameter and 4-mm deep (n=5). The distribution of the spectral radiant power that was delivered to the surface of the specimen and the light transmission through the 4-mm thick specimens was measured using an integrating sphere. Two-way ANOVA and Tukey tests (α=0.05) were applied. Results The Valo Grand produced the most homogeneous microhardness across the surfaces of the RBCs (p>0.05). When the Celalux 3, Bluephase 20i and Elipar DeepCure-S lights were used, the center of the specimens achieved greater hardness values compared to their outer regions (p<0.05). Approximately 10% of the radiant power delivered to the top reached the bottom of the specimen, although almost no violet light passed through 4mm of either RBC. A positive correlation was observed between the radiant exposure and microhardness. Significance The characteristics of the LCUs influenced the photoactivation of the RBCs. The use of a wide tip with a homogeneous light distribution is preferred when light curing RBCs using a bulk curing technique.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Photopolymerization techniques and applications · Dental Erosion and Treatment
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (26)
Show source-provided references
1. State-of-the-art: dental photocuring—a review10.1016/j.dental.2010.10.021 ↗
2. Light-curing units: a review of what we need to know10.1177/0022034515594786 ↗
3. Light output from six battery operated dental curing lights10.1016/j.msec.2016.07.033 ↗
4. Degree of conversion and microhardness of TPO-containing resin-based composites cured by polywave and monowave LED units10.1016/j.jdent.2012.03.007 ↗
5. Effects of radiant exposure values using second and third generation light curing units on the degree of conversion of a lucirin-based resin composite10.1590/1678-77572016-0388 ↗
6. Effect of a broad-spectrum LED curing light on the Knoop microhardness of four posterior resin based composites at 2, 4 and 6-mm depths10.1016/j.jdent.2015.11.004 ↗
7. Transmission of violet and blue light through conventional (layered) and bulk cured resin-based composites10.1016/j.jdent.2016.06.007 ↗
8. Influence of emission spectrum and irradiance on light curing of resin-based composites10.2341/16-349-L ↗
9. Light curing in dentistry10.1016/j.cden.2017.06.008 ↗
10. Bulk-fill resin composites: polymerization contraction, depth of cure, and gap formation10.2341/13-324-L ↗
11. Monomer conversion, microhardness, internal marginal adaptation, and shrinkage stress of bulk-fill resin composites10.1016/j.dental.2015.10.001 ↗
12. Characterizing the output settings of dental curing lights10.1016/j.jdent.2015.10.019 ↗
13. Effect of modulated photo-activation on polymerization shrinkage behavior of dental restorative resin composites10.1111/eos.12139 ↗
14. Effect of irradiance and light source on contraction stress, degree of conversion and push-out bond strength of composite restoratives
15. Insufficient cure under the condition of high irradiance and short irradiation time10.1016/j.dental.2008.07.007 ↗
16. Wayne · 1970
17. Evaluation of curing light distance on resin composite microhardness and polymerization10.2341/06-163 ↗
18. Ash · 2003
19. Curing-light attenuation in filled-resin restorative materials10.1016/j.dental.2005.11.009 ↗
20. Refractive index mismatch and monomer reactivity influence composite curing depth10.1177/154405910808700115 ↗
21. Real-time light transmittance monitoring for determining polymerization completeness of conventional and bulk fill dental composites10.2341/17-041-L ↗
22. Light-curing units used in dentistry: factors associated with heat development-potential risk for patients10.1007/s00784-016-1962-5 ↗
23. In vivo temperature rise in anesthetized human pulp during exposure to a polywave LED light curing unit10.1016/j.dental.2015.02.001 ↗
24. Molar extinction coefficients and the photon absorption efficiency of dental photoinitiators and light curing units10.1016/j.jdent.2004.11.013 ↗
25. Light curing in dentistry and clinical implications: a literature review10.1590/1807-3107bor-2017.vol31.0061 ↗
26. Examining exposure reciprocity in a resin based composite using high irradiance levels and real-time degree of conversion values10.1016/j.dental.2015.02.010 ↗