Innovative surfaces and alloys for dental implants: What about biointerface-safety concerns?
Source abstract
Abstract
OBJECTIVES: The present review article aimed to discuss the recent technologies employed for the development of dental implants, mainly regarding innovative surface treatments and alternative alloys, emphasizing the bio-tribocorrosion processes. METHODS: An electronic search applying specific MeSH terms was carried out in PubMed and Google Scholar databases to collect data until August 2021, considering basic, pre-clinical, clinical and review studies. The relevant articles (n=111), focused on innovative surface treatments for dental implants and their potential undesirable biological effects, were selected and explored. RESULTS: Novel texturization methodologies for dental implants clearly provided superficial and structural atomic alterations in micro- and nanoscale, promoting different mechanical-chemical interactions when applied in the clinical set. Some particulate metals released from implant surfaces, their degradation products and/or contaminants exhibited local and systemic reactions after implant installation and osseointegration, contributing to unexpected treatment drawbacks and adverse effects. Therefore, there is an urgent need for development of pre-clinical and clinical platforms for screening dental implant devices, to predict the biointerface reactions as early as possible during the development phases. SIGNIFICANCE: Modern surface treatments and innovative alloys developed for dental implants are not completely understood regarding their integrity during long-term clinical function, especially when considering the bio-tribocorrosion process. From this review, it is possible to assume that degradation and contamination of dental surfaces might be associated within peri-implant inflammation and cumulative long-lasting systemic toxicity. The in-depth comprehension of the biointerface modifications on these novel surface treatments might preclude unnecessary expenses and postoperative complications involving osseointegration failures.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Bone Tissue Engineering Materials · Orthopaedic implants and arthroplasty · Titanium Alloys Microstructure and Properties
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (100+)
Show source-provided references
1. Modifications of dental implant surfaces at the micro-and nano-level for enhanced osseointegration10.3390/ma13010089 ↗
2. A review of nanostructured surfaces and materials for dental implants: surface coating, patterning and functionalization for improved performance10.1039/C8BM00021B ↗
3. A bone preservation protocol that enables evaluation of osseointegration of implants with micro-and nanotextured surfaces10.1080/10520295.2018.1552017 ↗
4. Nano-morphology, crystallinity and surface potential of anatase on micro-arc oxidized titanium affect its protein adsorption, cell proliferation and cell differentiation10.1016/j.msec.2019.110204 ↗
5. Extension of hydrophilicity stability by reactive plasma treatment and wet storage on TiO2 nanotube surfaces for biomedical implant applications10.1098/rsif.2020.0650 ↗
6. Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions10.1111/prd.12179 ↗
7. Al2O3 particles on titanium dental implant systems following sandblasting and acid-etching process10.1155/2019/6318429 ↗
8. Comparison of early osseointegration between laser-treated/acid-etched and sandblasted/acid-etched titanium implant surfaces10.1007/s10856-018-6049-1 ↗
9. A comparative evaluation between aluminum and titanium dioxide microparticles for blasting the surface titanium dental implants: an experimental study in rabbits10.1111/clr.12973 ↗
10. Physical–chemical analyses of contaminations and internal holes in dental implants of pure commercial titanium
11. The chemical surface evaluation of black and white porous titanium granules and different commercial dental implants with energy‐dispersive x‐ray spectroscopy analysis10.1111/cid.12727 ↗
12. In vitro surface characteristics and impurity analysis of five different commercially available dental zirconia implants10.1186/s40729-018-0124-8 ↗
13. Surface characteristics of dental implants: a review10.1016/j.dental.2017.09.007 ↗
14. Metal nanoparticles released from dental implant surfaces: potential contribution to chronic inflammation and peri-implant bone loss10.3390/ma12122036 ↗
15. Can degradation products released from dental implants affect peri‐implant tissues?10.1111/jre.12479 ↗
16. New procedure of quantitative mapping of Ti and Al released from dental implant and Mg, Ca, Fe, Zn, Cu, Mn as physiological elements in oral mucosa by LA-ICP-MS10.1016/j.talanta.2017.07.058 ↗
17. In vitro transdermal absorption of Al2O3 nanoparticles10.1016/j.tiv.2019.04.015 ↗
18. In vitro and in vivo toxicity assessment of nanoparticles10.1007/s40089-017-0221-3 ↗
19. Biodistribution, excretion, and toxicity of inorganic nanoparticles
20. Antibacterial potential associated with drug-delivery built TiO2 nanotubes in biomedical implants10.1186/s13568-019-0777-6 ↗
21. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw10.1016/S0300-9785(81)80077-4 ↗
22. Suppl 1: a brief historical perspective on dental implants, their surface coatings and treatments10.2174/1874210601408010050 ↗
23. Customized dental implants: manufacturing processes, topography, osseointegration and future perspectives of 3D fabricated implants10.1016/j.bprint.2020.e00107 ↗
24. Osteoblastic cells behavior and bacterial early adhesion on macro, micro and nanostructured surfaces for biomedical implants applications10.11607/jomi.8069 ↗
25. Nanostructured titanium surfaces exhibit recalcitrance towards Staphylococcus epidermidis biofilm formation
26. Topography effects of pure titanium substrates on human osteoblast long-term adhesion10.1016/j.actbio.2004.11.009 ↗
27. The use of reduced healing times on ITI® implants with a sandblasted and acid‐etched (SLA) surface: early results from clinical trials on ITI® SLA implants10.1034/j.1600-0501.2002.130204.x ↗
28. 10-year outcomes with immediate and early loaded implants with a chemically modified SLA surface
29. Quantitative in vitro comparison of the thrombogenicity of commercial dental implants10.1111/cid.12737 ↗
30. Effect of anodization parameters on morphologies of TiO2 nanotube arrays and their surface properties
31. Improved osseointegration of dental titanium implants by TiO2 nanotube arrays with recombinant human bone morphogenetic protein-2: a pilot in vivo study
32. Hydroxyapatite and their use as coatings in dental implants: a review
33. Induction plasma sprayed nano hydroxyapatite coatings on titanium for orthopaedic and dental implants10.1016/j.surfcoat.2010.10.042 ↗
34. Surrounding tissue response to surface-treated zirconia implants10.3390/ma13010030 ↗
35. Bioactivity of zirconia nanotube arrays fabricated by electrochemical anodization10.1016/j.msec.2008.10.003 ↗
36. Laser-assisted fabrication and in vitro verification of functionalized surface for cells biointegration10.1016/j.optlastec.2020.106871 ↗
37. Laser surface pattering of titanium for improving the biological performance of dental implants10.1002/adhm.201600858 ↗
38. Laser surface texturing of zirconia-based ceramics for dental applications: a review10.1016/j.msec.2021.112034 ↗
39. Effect of surface alkali-based treatment of titanium implants on ability to promote in vitro mineralization and in vivo bone formation10.1016/j.actbio.2017.05.016 ↗
40. Nanostructured titanium surfaces fabricated by hydrothermal method: influence of alkali conditions on the osteogenic performance of implants10.1016/j.msec.2018.08.069 ↗
41. Titanium coatings and surface modifications: toward clinically useful bioactive implants10.1021/acsbiomaterials.6b00604 ↗
42. PLGA-amoxicillin-loaded layer formed on anodized Ti alloy as a hybrid material for dental implant applications10.1016/j.msec.2018.10.049 ↗
43. Comparison of osteoblast spreading on microstructured dental implant surfaces and cell behaviour in an explant model of osseointegration: a scanning electron microscopic study10.1111/j.1600-0501.2005.01168.x ↗
44. Relevant aspects in the surface properties in titanium dental implants for the cellular viability10.1016/j.msec.2016.03.049 ↗
45. Osteogenic response of human MSCs and osteoblasts to hydrophilic and hydrophobic nanostructured titanium implant surfaces10.1002/jbm.a.35852 ↗
46. Influence of porosity on mechanical properties and in vivo response of Ti6Al4V implants10.1016/j.actbio.2009.11.011 ↗
47. Oral tissue interactions and cellular response to zirconia implant-prosthetic components: a critical review10.3390/ma14112825 ↗
48. Residual contaminations of silicon-based glass, alumina and aluminum grits on a titanium surface after sandblasting10.1007/s12633-015-9287-6 ↗
49. Anodization as a promising surface treatment for drug delivery implants and a non-cytotoxic process for surface alteration: a pilot study
50. Elemental analysis of commercial zirconia dental implants—is “metal-free” devoid of metals?10.1016/j.jmbbm.2020.103759 ↗
51. Progression of bio-tribocorrosion in implant dentistry10.3389/fmech.2020.00001 ↗
52. Dental implants‐associated release of titanium particles: a systematic review10.1111/clr.13372 ↗
53. Fatigue induced changes in conical implant–abutment connections10.1016/j.dental.2015.09.004 ↗
54. Effects of pH on the electrochemical behaviour of titanium alloys for implant applications10.1007/s10856-008-3623-y ↗
55. Influence of contact configuration and lubricating conditions on the microtriboactivity of the zirconia-Ti6Al4V pair used in dental applications10.1016/j.jmbbm.2018.12.009 ↗
56. Corrosion behaviour of titanium in the presence of Streptococcus mutans10.1016/j.jdent.2013.03.008 ↗
57. A comparative evaluation of ion release from different commercially-available orthodontic mini-implants-an in-vitro study10.21307/aoj-2020-124 ↗
58. FDA · 2019
59. Metals, autoimmunity, and neuroendocrinology: is there a connection?10.1016/j.envres.2020.109541 ↗
60. Cytotoxicity study of some Ti alloys used as biomaterial10.1016/j.msec.2008.10.021 ↗
61. Chelation in metal intoxication—principles and paradigms10.1016/j.jtemb.2014.10.001 ↗
62. Delayed-type hypersensitivity to metals in connective tissue diseases and fibromyalgia10.1016/j.envres.2017.12.004 ↗
63. Systematic review of potential health risks posed by pharmaceutical, occupational and consumer exposures to metallic and nanoscale aluminum, aluminum oxides, aluminum hydroxide and its soluble salts10.3109/10408444.2014.934439 ↗
64. Aluminum oxide nanoparticles induce structural changes in tau and cytotoxicity of the neuroblastoma cell line10.1016/j.ijbiomac.2018.08.182 ↗
65. Metal concentrations in the serum and hair of patients with titanium alloy spinal implants10.1097/01.BRS.0000065482.41115.B4 ↗
66. In vitro evaluation of cytotoxicity and corrosion behavior of commercially pure titanium and Ti-6Al-4V alloy for dental implants10.4103/0972-4052.197936 ↗
67. Vanadium ionic species from degradation of Ti-6Al-4V metallic implants: in vitro cytotoxicity and speciation evaluation10.1016/j.msec.2018.11.090 ↗
68. A literature review study on atomic ions dissolution of titanium and its alloys in implant dentistry10.3390/ma12030368 ↗
69. Titanium as a modifier of the peri‐implant microbiome structure10.1111/cid.12676 ↗
70. Autophagy induced by silica nanoparticles protects RAW264. 7 macrophages from cell death10.1016/j.tox.2017.01.019 ↗
71. Cytotoxic and genotoxic characterization of aluminum and silicon oxide nanoparticles in macrophages10.1016/j.dental.2015.02.009 ↗
72. Metal elements in tissue with dental peri‐implantitis: a pilot study10.1111/clr.12718 ↗
73. Orthopaedic implant related metal toxicity in terms of human lymphocyte reactivity to metal-protein complexes produced from cobalt-base and titanium-base implant alloy degradation10.1023/A:1017979710992 ↗
74. Titanium, chromium and cobalt ions modulate the release of bone-associated cytokines by human monocytes/macrophages in vitro10.1016/0142-9612(96)00072-5 ↗
75. Cytotoxicity of dental implants: the effects of ultrastructural elements10.11607/jomi.5962 ↗
76. Effects of metallic ion toxicity on human gingival fibroblasts morphology10.1016/S0142-9612(99)00044-7 ↗
77. Development of novel Ti–Mo–Mn alloys for biomedical applications10.1038/s41598-020-62865-4 ↗
78. In vitro evaluation of cytotoxicity and genotoxicity of a commercial titanium alloy for dental implantology10.1016/j.mrgentox.2010.06.013 ↗
79. Engineered nanomaterials in the environment: bioaccumulation, biomagnification and biotransformation
80. Titanium ions form particles that activate and execute interleukin‐1β release from lipopolysaccharide‐primed macrophages10.1111/jre.12364 ↗
81. Assessment of the genetic risks of a metallic alloy used in medical implants10.1590/S1415-47572010005000118 ↗
82. Response of UMR 106 cells exposed to titanium oxide and aluminum oxide nanoparticles10.1002/jbm.a.32339 ↗
83. In-vitro and in-vivo, cytotoxicity evaluation of cast functionally graded biomaterials for dental implantology10.1016/j.msec.2018.09.003 ↗
84. Acute cytotoxic effects of silica microparticles used for coating of plastic blood-collection tubes on human periosteal cells
85. Cellular toxicity of silicon carbide nanomaterials as a function of morphology10.1016/j.biomaterials.2018.06.027 ↗
86. Influence of canadium 4+ and 5+ ions on the differentiation and activation of human osteoclasts10.1155/2017/9439036 ↗
87. Effect of vanadium released from micro-arc oxidized porous Ti6Al4V on biocompatibility in orthopedic applications10.1016/j.colsurfb.2018.05.044 ↗
88. Increased levels of dissolved titanium are associated with peri‐implantitis—a cross‐sectional study10.1902/jop.2016.160524 ↗
89. Complex cytotoxicity mechanism of bundles formed from self-organised 1-D anodic TiO2 nanotubes layers10.1016/j.jhazmat.2020.122054 ↗
90. A vessel subtype beneficial for osteogenesis enhanced by strontium-doped sodium titanate nanorods by modulating macrophage polarization10.1039/D0TB00282H ↗
91. Wear particles induce a new macrophage phenotype with the potential to accelerate material corrosion within total hip replacement interfaces10.1016/j.actbio.2019.10.039 ↗
92. Nanointeraction: the profound influence of nanostructured and nano-drug delivery biomedical implant surfaces on cell behavior10.1016/j.cis.2020.102265 ↗
93. Metallic-nanoparticle release systems for biomedical implant surfaces: effectiveness and safety10.1080/17435390.2021.1915401 ↗
94. Antibacterial activity and inflammation inhibition of ZnO nanoparticles embedded TiO2 nanotubes10.1088/1361-6528/aabac1 ↗
95. Antibacterial nano-structured titania coating incorporated with silver nanoparticles10.1016/j.biomaterials.2011.04.040 ↗
96. Extracellular electron transfer from aerobic bacteria to Au-loaded TiO2 semiconductor without light: a new bacteria-killing mechanism other than localized surface plasmon resonance or microbial fuel cells10.1021/acsami.6b10052 ↗
97. Metal TiO2 nanotube layers for the treatment of dental implant infections10.1021/acsami.8b04045 ↗
98. Long-term antibacterial characteristics and cytocompatibility of titania nanotubes loaded with Au nanoparticles without photocatalytic effects10.1016/j.apsusc.2017.04.053 ↗
99. Strontium (Sr) and silver (Ag) loaded nanotubular structures with combined osteoinductive and antimicrobial activities10.1016/j.actbio.2015.11.046 ↗
100. Antibacterial effects and biocompatibility of titanium surfaces with graded silver incorporation in titania nanotubes10.1016/j.biomaterials.2014.02.005 ↗