The role of cortical zone level and prosthetic platform angle in dental implant mechanical response: A 3D finite element analysis
Source abstract
Abstract
Objective The aim of this study was to evaluate the influence of three different dental implant neck geometries, under a combined compressive/shear load using finite element analysis (FEA). The implant neck was positioned in D2 quality bone at the crestal level or 2 mm below. Methods One dental implant (4.2 × 9 mm) was digitized by reverse engineering techniques using micro CT and imported into Computer Aided Design (CAD) software. Non-uniform rational B-spline surfaces were reconstructed, generating a 3D volumetric model similar to the digitized implant. Three different models were generated with different implant neck configurations, namely 0°, 10° and 20°. D2 quality bone, composed of cortical and trabecular structure, was modeled using data from CT scans. The implants were included in the bone model using a Boolean operation. Two different fixture insertion depths were simulated for each implant: 2 mm below the crestal bone and exactly at the level of the crestal bone. The obtained models were imported to FEA software in STEP format. Von Mises equivalent strains were analyzed for the peri-implant D2 bone type, considering the magnitude and volume of the affected surrounding cortical and trabecular bone. The highest strain values in both cortical and trabecular tissue at the peri-implant bone interface were extracted and compared. Results All implant models were able to distribute the load at the bone-implant contact (BIC) with a similar strain pattern between the models. At the cervical region, however, differences were observed: the models with 10° and 20° implant neck configurations (Model B and C), showed a lower strain magnitude when compared to the straight neck (Model A). These values were significantly lower when the implants were situated at crestal bone levels. In the apical area, no differences in strain values were observed. Significance The implant neck configuration influenced the strain distribution and magnitude in the cortical bone and cancellous bone tissues. To reduce the strain values and improve the load dissipation in the bone tissue, implants with 10° and 20 neck configuration should be preferred instead of straight implant platforms.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental Implant Techniques and Outcomes · Bone Tissue Engineering Materials · Orthodontics and Dentofacial Orthopedics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (50)
Show source-provided references
1. Simulation of peri-implant bone healing due to immediate loading in dental implant treatments10.1016/j.jbiomech.2012.12.023 ↗
2. A systematic review on marginal bone loss around short dental implants (<10 mm) for implant-supported fixed prostheses10.1111/clr.12236 ↗
3. Wolff’s law of trabecular architecture at remodeling equilibrium10.1115/1.3138584 ↗
4. Toward an understanding of implant occlusion and strain adaptive bone modeling and remodeling10.1016/S0022-3913(99)70209-X ↗
5. An adaptation model for trabecular bone at different mechanical levels10.1186/1475-925X-9-32 ↗
6. Mechanical basis of bone strength: influence of bone material, bone structure and muscle action
7. Evaluation of bone remodeling around single dental implants of different lengths: a mechanobiological numerical simulation and validation using clinical data10.1080/10255842.2015.1052418 ↗
8. Finite element analysis of dental implant loading on atrophic and non-atrophic cancellous and cortical mandibular bone — a feasibility study10.1016/j.jbiomech.2014.10.019 ↗
9. Platform switching minimises crestal bone loss around dental implants: truth or myth?10.1111/joor.12189 ↗
10. Influence of implant neck surface and placement depth on crestal bone changes around platform-switched implants: a clinical and radiographic study in dogs10.1902/jop.2017.170192 ↗
11. Mechanical behaviour of dental implants10.1016/j.prostr.2016.02.005 ↗
12. Implant success, survival, and failure: the International Congress of Oral Implantologists (ICOI) Pisa Consensus Conference10.1097/ID.0b013e3181676059 ↗
13. Influence of ceramic materials on biomechanical behavior of implant supported fixed prosthesis with hybrid abutment
14. Capacity to maintain placement torque at removal, single load-to-Failure, and stress concentration of straight and angled abutments10.11607/prd.3998 ↗
15. Digital image correlation and finite element analysis of bone strain generated by implant-retained cantilever fixed prosthesis
16. Rehabilitation of anterior maxilla with a novel hyperbolic profile transmucosal implant in elderly patients10.23736/S0026-4970.19.04259-6 ↗
17. Factors affecting soft and hard tissues around two-piece transmucosal implants: a 3-year prospective cohort study10.11607/jomi.7778 ↗
18. A 3-year prospective cohort study on 132 calcium phosphate-blasted implants: flap vs flapless technique10.11607/jomi.4623 ↗
19. The use of different adhesive filling material and mass combinations to restore class II cavities under loading and shrinkage effects: a 3D-FEA10.1080/10255842.2020.1836168 ↗
20. Effects of thread features in osseo-integrated titanium implants using a statistics-based finite element method10.1016/j.dental.2012.04.035 ↗
21. Influence of bone quality on the mechanical interaction between implant and bone: a finite element analysis10.1016/j.jdent.2019.06.008 ↗
22. The effect of stemless humeral component fixation feature design on bone stress and strain response: a finite element analysis10.1016/j.jse.2018.06.002 ↗
23. Mechanical behavior of conceptual posterior dental crowns with functional elasticity gradient
24. Stress distribution of bulk-fill resin composite in class II restorations
25. A novel approach for a complete 3D tooth reconstruction using only 3D crown data10.1007/s12008-012-0166-8 ↗
26. Adhesive class I restorations in sound molar teeth incorporating combined resin-composite and glass ionomer materials: CAD-FE modeling and analysis10.1016/j.dental.2019.07.017 ↗
27. The influence of custom-milled framework design for an implant-supported full-arch fixed dental prosthesis: 3D-FEA sudy10.3390/ijerph17114040 ↗
28. Finite element analysis of peri-implant bone volume affected by stresses around Morse taper implants: effects of implant positioning to the bone crest10.1080/10255842.2018.1507025 ↗
29. Wolff’s Law and bone’s structural adaptations to mechanical usage: an overview for clinicians
30. Parafunctional loading and occlusal device on stress distribution around implants: a 3D finite element analysis10.1016/j.prosdent.2017.12.023 ↗
31. Finite element analysis of stress in bone adjacent to dental implants10.1563/1548-1336(2008)34[249:FEAOSI]2.0.CO;2 ↗
32. Influence of forces on peri-implant bone10.1111/j.1600-0501.2006.01360.x ↗
33. The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: a three-dimensional finite element analysis10.1016/S0022-3913(08)60259-0 ↗
34. Understanding peri-implant endosseous healing10.1002/j.0022-0337.2003.67.8.tb03681.x ↗
35. Multi-factorial analysis of variables influencing the bone loss of an implant placed in the maxilla: prediction using FEA and SED bone remodeling algorithm10.1016/j.jbiomech.2009.10.030 ↗
36. Micro finite element analysis of dental implants under different loading conditions10.1016/j.compbiomed.2018.03.012 ↗
37. Effects of implant diameter, insertion depth, and loading angle on stress/strain fields in implant/jawbone systems: finite element analysis
38. Influence of implant length and bicortical anchorage on implant stress distribution10.1111/j.1708-8208.2003.tb00208.x ↗
39. Does the prosthesis weight matter? 3D finite element analysis of a fixed implant-supported prosthesis at different weights and implant numbers10.4047/jap.2020.12.2.67 ↗
40. Stress and strain distributions on short implants with two different prosthetic connections — an in vitro and in silico analysis10.14295/bds.2017.v20i3.1433 ↗
41. Biomechanical evaluation of stress distribution in subcrestal placed platform-switched short dental implants in D4 bone: in vitro finite element model study10.4103/jpbs.JPBS_44_20 ↗
42. Influence of thread shape and inclination on the biomechanical behaviour of plateau implant systems10.1016/j.dental.2018.01.012 ↗
43. Modal analysis for implant stability assessment: sensitivity of this methodology for different implant designs10.1016/j.dental.2018.05.016 ↗
44. Effect of implant number and height on the biomechanics of full arch prosthesis10.20396/bjos.v17i0.8653837 ↗
45. Finite element analysis of narrow dental implants10.1016/j.dental.2020.04.013 ↗
46. Evaluation of stress induced in peri-implant bone tissue by misfit in multi-implant prosthesis10.1016/j.dental.2005.08.001 ↗
47. Influences of implant neck design and implant-abutment joint type on peri-implant bone stress and abutment micromovement: three-dimensional finite element analysis10.1016/S0022-3913(13)60340-6 ↗
48. Effects of tightening torque on screw stress and formation of implant-abutment microgaps: a finite element analysis
49. Survival rate and deformation of external hexagon implants with one-piece Zirconia crowns10.3390/met11071068 ↗
50. Evaluation of stresses on implant, bone, and restorative materials caused by different opposing arch materials in hybrid prosthetic restorations using the All-on-4 technique10.3390/ma14154308 ↗