journal article·2024-07

The influence of filler load in 3D printing resin-based composites

Ana Cristina Andrioli Zattera, Francisco Amaro Morganti, Gabriela de Souza Balbinot, Alvaro Della Bona, Fabricio Mezzomo Collares

Dental Materials· Volume 40· Issue 7
Publisher page

Abstract

Objective To evaluate the influence of the barium glass (BG) filler in 3D printing resin-based composites for restorative structures. Methods Experimental 3D printing resin-based composites were formulated with UDMA 70%wt, Bis-EMA 20%wt, and TEGDMA 10%wt. Photoinitiators TPO and DFI (2%wt) were used. BG was incorporated at 40%wt and 50%wt. 0%wt BG was used as negative control and the VarseoSmile Crownplus (Bego) was used as a commercial control. Specimens were printed using a 3D printer. Subsequently, specimens were washed and submitted to post-curing with 405 nm at 60ºC for 2 × 20 min at FormCure (FormLabs). 3D printing resin-based composites were evaluated by flexural strength, degree of conversion, softening in solvent, radiopacity, and cytotoxicity against gingival fibroblasts. Data were statistically analyzed using one-way ANOVA (α = 0.05). Results No significant differences in flexural strength were showed between BG40% (90.5 ± 5,4 MPa), BG50% (102.0 ± 11.7 MPa) and VA (105.2 ± 11.7 MPa). Addition of 40% and 50% of BG showed no influence in the degree of conversion compared to VA (p > 0.05). All groups showed softening in solvent after immersion in ethanol (p < 0.05). All groups showed more than 1mmAl of radiopacity. BG50% showed significantly higher radiopacity (2.8 ± 0.3 mmAl) than other groups (p < 0,05). Cytotoxicity evaluation showed gingival cell viability higher than 80% for all groups. Significance Addition of up to 50%wt of barium glass in experimental 3D printing resin-based composites showed promising results for long-term restorative structures.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Bone Tissue Engineering Materials · Dental Implant Techniques and Outcomes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (56)

Show source-provided references
1. Three-dimensional (3D) printing in dental practice: applications, areas of interest, and level of evidence10.1007/s00784-023-04983-7 ↗
2. 3D printing restorative materials using a stereolithographic technique: a systematic review10.1016/j.dental.2020.11.030 ↗
3. A review of multi-material 3D printing of functional materials via vat photopolymerization10.3390/polym14122449 ↗
4. Current and emerging applications of 3D printing in restorative dentistry10.1007/s40496-018-0181-3 ↗
5. ISO 4049:2019. Dentistry-Polymer-based filling, restorative and luting materials n.d.
6. Resin composite—state of the art10.1016/j.dental.2010.10.020 ↗
7. Hygroscopic and hydrolytic effects in dental polymer networks10.1016/j.dental.2005.05.005 ↗
8. Engineering a new generation of thermoset self-healing polymers based on intrinsic approaches
9. Radiopacity vs. composition of some barium and strontium glass composites10.1016/0300-5712(87)90096-0 ↗
10. 3D printing of high viscosity uv-curable resin for highly stretchable and resilient elastomer10.1002/adma.202304430 ↗
11. New inorganic components for dental filling composites10.1007/s00706-004-0254-y ↗
12. Mechanical properties, accuracy, and cytotoxicity of UV-polymerized 3D printing resins composed of Bis-EMA, UDMA, and TEGDMA10.1016/j.prosdent.2019.05.002 ↗
13. Effects of acetyl tributyl citrate on the mechanical properties, abrasion resistance, and cytotoxicity of the light-cured 3D printing polyurethane resins10.1089/3dp.2023.0161 ↗
14. Niobium silicate particles as bioactive fillers for composite resins10.1016/j.dental.2020.09.010 ↗
15. Refractive index mismatch and monomer reactivity influence composite curing depth10.1177/154405910808700115 ↗
16. X-ray-opaque reinforcing fillers for composite materials10.1177/00220345690480013101 ↗
17. Discrepancies in degree of conversion measurements by FTIR
18. Quantum dots as nonagglomerated nanofillers for adhesive resins10.1177/0022034516656838 ↗
19. ISO 28642:2016. Guidance on colour measurement n.d.
20. Color difference thresholds in dentistry10.1111/jerd.12149 ↗
21. ISO 13116:2020. Test method for determining radio-opacity of materials n.d.
22. ISO 10993–5:2009. Biological evaluation of medical devices Part 5: Tests for in vitro cytotoxicity n.d.
23. Role of filler and functional group conversion in the evolution of properties in polymeric dental restoratives10.1016/j.dental.2014.02.015 ↗
24. Mechanical properties and filler fraction of dental composites10.1016/0109-5641(89)90128-0 ↗
25. Biomechanical properties of a 3D printing polymer for provisional restorations and artificial teeth10.1016/j.dental.2022.11.004 ↗
26. Influence of printing orientation on mechanical properties of aged 3D-printed restorative resins10.1016/j.dental.2024.02.023 ↗
27. In vitro investigation of the influence of printing direction on the flexural strength, flexural modulus and fractographic analysis of 3D-printed temporary materials10.4012/dmj.2020-147 ↗
28. Build angle and its influence on the flexure strength of stereolithography printed hybrid resin material. An in vitro study and a fractographic analysis10.1080/10667857.2018.1467071 ↗
29. Photoinitiator type and applicability of exposure reciprocity law in filled and unfilled photoactive resins10.1016/j.dental.2010.09.011 ↗
30. Experimental composite resin with myristyltrimethylammonium bromide (MYTAB) and alpha-tricalcium phosphate (α-TCP): antibacterial and remineralizing effect10.3390/jfb14060303 ↗
31. Effect of calcium orthophosphate: reinforcing glass ratio and prolonged water storage on flexural properties of remineralizing composites10.1016/j.jmbbm.2020.103637 ↗
32. Effects of monomer ratios and highly radiopaque fillers on degree of conversion and shrinkage-strain of dental resin composites10.1016/j.dental.2009.06.009 ↗
33. Influence of different calcium phosphates on an experimental adhesive resin
34. Niobium containing bioactive glasses as remineralizing filler for adhesive resins10.1016/j.dental.2019.11.014 ↗
35. Mineral deposition promoted by resin-based sealants with different calcium phosphate additions10.1590/1807-3107bor-2019.vol33.0101 ↗
36. Antibacterial and remineralizing fillers in experimental orthodontic adhesives10.3390/ma12040652 ↗
37. Effect of different photoinitiators and reducing agents on cure efficiency and color stability of resin-based composites using different LED wavelengths10.1016/j.jdent.2015.08.015 ↗
38. Iodonium salt incorporation in dental adhesives and its relation with degree of conversion, ultimate tensile strength, cell viability, and oxidative stress10.1007/s00784-018-2527-6 ↗
39. Onium salt reduces the inhibitory polymerization effect from an organic solvent in a model dental adhesive resin10.1002/jbm.b.30995 ↗
40. Urethane dimethacrylate-based photopolymerizable resins for stereolithography 3D printing: a physicochemical characterisation and biocompatibility evaluation10.1007/s13346-023-01391-y ↗
41. Chemistry of silanes: interfaces in dental polymers and composites10.6028/jres.110.081 ↗
42. Influence of fillers on the water sorption of composites10.1016/0109-5641(89)90077-8 ↗
43. Silane adhesion mechanism in dental applications and surface treatments: a review10.1016/j.dental.2017.09.002 ↗
44. Mesoporous silica fillers and resin composition effect on dental composites cytocompatibility10.1016/j.dental.2016.11.009 ↗
45. In-vitro cytocompatibility of dental resin monomers on osteoblast-like cells10.1016/j.jdent.2017.07.008 ↗
46. Molecular toxicology of substances released from resin–based dental restorative materials10.3390/ijms10093861 ↗
47. Limitations of the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-2H-tetrazolium bromide (MTT) assay when compared to three commonly used cell enumeration assays10.1186/s13104-015-1000-8 ↗
48. Radiographic caries detection: a systematic review and meta-analysis10.1016/j.jdent.2015.02.009 ↗
49. Effect of filler properties in composite resins on light transmittance characteristics and color10.4012/dmj.26.38 ↗
50. RoBDEMAT: a risk of bias tool and guideline to support reporting of pre-clinical dental materials research and assessment of systematic reviews10.1016/j.jdent.2022.104350 ↗
51. Optical behavior of 3D-printed dental restorative resins: influence of thickness and printing angle10.1016/j.dental.2023.08.003 ↗
52. Color and optical properties of 3D printing restorative polymer‐based materials: a scoping review10.1111/jerd.12904 ↗
53. Longevity of posterior composite restorations: a systematic review and meta-analysis10.1177/0022034514544217 ↗
54. A randomized controlled 30 years follow up of three conventional resin composites in Class II restorations10.1016/j.dental.2015.08.146 ↗
55. A randomized controlled 27 years follow up of three resin composites in Class II restorations10.1016/j.jdent.2015.09.003 ↗
56. Antibacterial response of oral microcosm biofilm to nano-zinc oxide in adhesive resin10.1016/j.dental.2020.11.022 ↗