Accuracy of metal 3D printed frameworks for removable partial dentures evaluated by digital superimposition
Source abstract
Abstract
Objectives To evaluate the accuracy of metal 3D printed frameworks (MEP group) for removable partial dentures (RPDs) by digital superimposition, in comparison to that of frameworks produced by the conventional (CON group) and resin printing/casting (RPC group) workflows. Methods A partially edentulous maxillary dentiform was prepared with rest seats and guiding planes on the right canine, left first premolar, and left second molar. Thirty master casts were prepared via repeated impressions of the dentiform. Frameworks were fabricated by three different workflows (n = 10 for each group). The internal discrepancies of the frameworks were assessed at 12 points by digital scanning with an optical triangulation principle-based tabletop scanner and superimposition using a reference best-fit alignment method. First, the master cast was scanned alone. Subsequently, a thin silicone material was applied to the framework and fitted onto the master cast, after which the framework was removed. Finally, the master cast with the silicone material attached was rescanned. The data from the two scans were matched, with the reference being the area not occupied by the silicone. Results For the CON, MEP, and RPC groups, respectively, the mean overall internal discrepancies (279.72 µm, 241.02 µm, and 331.70 µm), and the mean internal discrepancies on palate areas (292.92 µm, 250.72 µm, and 355.84 µm) and rest seat areas (240.12 µm, 211.91 µm, and 259.26 µm) did not significantly differ among the three fabrication methods (p = 0.558, 0.542, and 0.774). Significance The reference best-fit alignment of scan datasets is a useful approach to evaluate the internal discrepancy of frameworks. Metal 3D printing produces RPD frameworks that are comparable to conventional frameworks and meet clinical standards.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Anatomy and Medical Technology · Additive Manufacturing and 3D Printing Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (48)
Show source-provided references
1. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques10.1016/j.prosdent.2016.02.017 ↗
2. In vitro evaluation of marginal discrepancy of monolithic zirconia restorations fabricated with different CAD-CAM systems10.1016/j.prosdent.2016.09.011 ↗
3. CAD-CAM milled versus rapidly prototyped (3D-printed) complete dentures: an in vitro evaluation of trueness10.1016/j.prosdent.2018.09.001 ↗
4. Assessment of metal sleeve-free 3D-printed implant surgical guides10.1016/j.dental.2019.01.001 ↗
5. Suitability of 3D printed pieces of nanocrystalline zirconia for dental applications10.1016/j.dental.2020.01.006 ↗
6. Load-bearing capacity of CAD/CAM 3D-printed zirconia, CAD/CAM milled zirconia, and heat-pressed lithium disilicate ultra-thin occlusal veneers on molars10.1016/j.dental.2020.01.016 ↗
7. Precision of 3D-printed splints with different dental model offsets10.1016/j.ajodo.2018.09.012 ↗
8. Additive technology: update on current materials and applications in dentistry10.1111/jopr.12510 ↗
9. Accuracy of CAD-CAM-fabricated removable partial dentures10.1016/j.prosdent.2017.04.017 ↗
10. Evaluation of removable partial denture frameworks fabricated using 3 different techniques10.1016/j.prosdent.2018.10.013 ↗
11. Virtual evaluation of the accuracy of fit and trueness in maxillary poly(etheretherketone) removable partial denture frameworks fabricated by direct and indirect CAD/CAM techniques10.1111/jopr.13075 ↗
12. An in vitro investigation of accuracy and fit of conventional and CAD/CAM removable partial denture frameworks10.1111/jopr.12997 ↗
13. A technique for fabricating patterns for removable partial denture frameworks using digitized casts and electronic surveying10.1016/j.prosdent.2003.10.002 ↗
14. Use of CAD/CAM technology to fabricate a removable partial denture framework10.1016/j.prosdent.2006.05.029 ↗
15. Basic powder metallurgical aspects in selective metal powder sintering10.1016/S0007-8506(07)63043-1 ↗
16. Binding mechanisms in selective laser sintering and selective laser melting10.1108/13552540510573365 ↗
17. Additive manufacturing of metallic components – process, structure and properties10.1016/j.pmatsci.2017.10.001 ↗
18. Evidence supporting a mechanistic role of sirtuins in mood and metabolic disorders10.1016/j.pnpbp.2018.05.017 ↗
19. Comparative analysis of structure and hardness of cast and direct metal laser sintering produced Co-Cr alloys used for dental devices10.1108/RPJ-04-2014-0051 ↗
20. Accuracy of removable partial denture framework fabricated by casting with a 3D printed pattern and selective laser sintering
21. Clinical evaluation of removable partial denture rest seat adaptation10.1016/0022-3913(85)90015-0 ↗
22. Accuracy of the palatal plate of removable partial dentures, and influence of laboratory handling of the investment on the accuracy10.1016/S0109-5641(86)80066-5 ↗
23. Comparison of adaptation between the major connectors fabricated from intraoral digital impressions and extraoral digital impressions10.1038/s41598-017-17839-4 ↗
24. Marginal and internal fit of pressed ceramic crowns made from conventional and computer-aided design and computer-aided manufacturing wax patterns: an in vitro comparison10.1016/j.prosdent.2015.12.005 ↗
25. Monolithic zirconia dental crowns. Internal fit, margin quality, fracture mode and load at fracture10.1016/j.dental.2017.06.009 ↗
26. The effect of scanning distance on the accuracy of intra-oral scanners used in dentistry10.1002/ca.23334 ↗
27. Clinical study of the influence of ambient light scanning conditions on the accuracy (Trueness and Precision) of an intraoral scanner10.1111/jopr.13135 ↗
28. A comparison of accuracy of 3 intraoral scanners: a single-blinded in vitro study10.1016/j.prosdent.2019.10.023 ↗
29. Phase shifting algorithms for fringe projection profilometry: a review10.1016/j.optlaseng.2018.04.019 ↗
30. Fringe projection techniques: whither we are?10.1016/j.optlaseng.2009.09.001 ↗
31. Automated phase-measuring profilometry of 3-D diffuse objects10.1364/AO.23.003105 ↗
32. On-line automated phase-measuring profilometry10.1016/0143-8166(91)90029-S ↗
33. Method for registration of 3-D shapes. Sensor fusion IV: control paradigms and data structures
34. Impact of manual control point selection accuracy on automated surface matching of digital dental models10.1007/s00784-017-2155-6 ↗
35. A method to evaluate profilometric tooth wear measurements10.1016/j.dental.2011.10.002 ↗
36. Investigation into the accuracy and measurement methods of sequential 3D dental scan alignment10.1016/j.dental.2019.01.012 ↗
37. Statistical generalized phase-shifting digital holography with a continuous fringe-scanning scheme10.1364/OL.40.003149 ↗
38. A clinical investigation of the fit of removable partial dental prosthesis clasp assemblies10.1016/j.prosdent.2006.02.001 ↗
39. Effect of anchorage on the accuracy of fit in removable partial denture framework10.1111/j.1532-849X.2010.00594.x ↗
40. Adaptation of removable partial denture frameworks fabricated by selective laser melting10.1016/j.prosdent.2018.11.010 ↗
41. Accuracy of a digital removable partial denture fabricated by casting a rapid prototyped pattern: a clinical study10.1016/j.prosdent.2016.12.007 ↗
42. Feasibility of a 3D surgical guide technique for impacted supernumerary tooth extraction: a pilot study with 3D printed simulation models
43. Flexural strength of 3D-printing resin materials for provisional fixed dental prosthese
44. Accuracy improvement of intraoral scanning and buccal bite registration using healing abutment as landmarks: an in vitro study
45. An improved prediction of residual stresses and distortion in additive manufacturing10.1016/j.commatsci.2016.10.003 ↗
46. Applications of structural optimization in direct metal fabrication10.1108/13552540810862082 ↗
47. Application of layout optimization to the design of additively manufactured metallic components10.1007/s00158-016-1426-1 ↗
48. Effects of scanning strategy and scanner type on the accuracy of intraoral scans: a new approach for assessing the accuracy of scanned data10.1111/jopr.13158 ↗