Laboratory methods to simulate the mechanical degradation of resin composite restorations
Source abstract
Abstract
Objectives This study reviewed the literature to identify in vitro approaches that have been used to simulate the mechanical degradation and fatigue of resin composite restorations. Methods A search for articles was carried out in 4 databases and included studies in which composite restorations were bonded to teeth and subject to cyclic loading. Articles were assessed for eligibility, and the following items were the extracted from the included studies: authors, country, year, materials tested, simulation device and details including load magnitude and frequency, number of cycles, type of antagonist, test medium, and temperature. Data were analyzed descriptively. Results The 49 studies included showed a high level of heterogeneity in methods, devices, and test parameters. Nineteen different simulation devices were used, applying loads varying between 30 and 2900 N, and frequencies varying between 0.4 and 12 Hz. The load and frequency used most often were ~ 50 N (63.3%) and 1.5-1.7 Hz (32.7%). The number of cycles varied between 10 K and 2.4 M, 1.2 M was the most prevalent (40.8%). The majority of studies combined cyclic loading with at least one additional aging method: static liquid storage, thermo-mechanical cycling applied simultaneously, and thermal cycling as a discrete aging step were the three most frequent methods. The overall evidence indicated reporting problems, and suggested a lack of clinical validation of the research methods used. Significance Validation studies, underlying clinical supporting data, and better reporting practices are needed for further improving research on the topic. Specific suggestions for future studies are provided.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Dental Erosion and Treatment · Endodontics and Root Canal Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (100+)
Show source-provided references
1. Ageing of dental composites based on methacrylate resins-a critical review of the causes and method of assessment
2. Lifetime prediction of biodegradable polymers
3. Mechanical degradation of different classes of composite resins aged in water, air, and oil
4. Gates · 2008 · 3
5. Association between masticatory performance and maximal occlusal force in young men10.1046/j.1365-2842.2003.01009.x ↗
6. Biomechanical factors affecting the bone-dental implant interface10.1016/0267-6605(92)90049-Y ↗
7. Conservative restoration of severely damaged endodontically treated premolar teeth: a FEM study10.1007/s00784-010-0397-7 ↗
8. Fracture-resistant monolithic dental crowns10.1016/j.dental.2015.12.010 ↗
9. Effects of geometry on fracture initiation and propagation in all-ceramic crowns10.1002/jbm.b.31133 ↗
10. Factors involved in mechanical fatigue degradation of dental resin composites10.1177/0022034513490734 ↗
11. Fatigue testing of biomaterials and their interfaces10.1016/j.dental.2017.01.012 ↗
12. Resin-based composite performance: are there some things we can’t predict?10.1016/j.dental.2012.06.013 ↗
13. On the durability of resin–dentin bonds: identifying the weakest links10.1016/j.dental.2015.06.011 ↗
14. Optimization of large MOD restorations: composite resin inlays vs. short fiber-reinforced direct restorations10.1016/j.dental.2018.01.004 ↗
15. Accelerated fatigue resistance of thick CAD/CAM composite resin overlays bonded with light- and dual-polymerizing luting resins
16. Fatigue resistance of ultrathin CAD/CAM complete crowns with a simplified cementation process10.1016/j.prosdent.2015.04.014 ↗
17. Fatigue resistance and crack propensity of large MOD composite resin restorations: direct versus CAD/CAM inlays10.1016/j.dental.2012.11.013 ↗
18. Computer-aided-design/computer-assisted-manufactured adhesive restoration of molars with a compromised cusp: effect of fiber-reinforced immediate dentin sealing and cusp overlap on fatigue strength10.1111/j.1708-8240.2011.00433.x ↗
19. Novel-design ultra-thin CAD/CAM composite resin and ceramic occlusal veneers for the treatment of severe dental erosion10.1016/S0022-3913(11)60035-8 ↗
20. In vitro fatigue resistance of CAD/CAM composite resin and ceramic posterior occlusal veneers10.1016/S0022-3913(10)60111-4 ↗
21. Effect of tooth brush abrasion and thermo-mechanical loading on direct and indirect veneer restorations10.1007/s00784-014-1209-2 ↗
22. Partial coverage restoration systems on molars - comparison of failure load after exposure to a mastication simulator10.1111/j.1365-2842.2006.01529.x ↗
23. Retention of restorations placed in noncarious cervical lesions after centric and eccentric occlusal loading in a chewing simulator - a pilot study
24. Enamel wear by antagonistic restorative materials under erosive conditions10.1007/s00784-017-2071-9 ↗
25. Two-body wear of artificial acrylic and composite resin teeth in relation to antagonist material10.1016/S0022-3913(09)60051-2 ↗
26. Influence of different load application devices on fracture resistance of restored premolars10.1590/S0103-64402012000500003 ↗
27. Fatigue and fracture resistance of minimally invasive ceramic and resin composite veneers with different designs bonded adhesively to severely eroded teeth10.1080/01694243.2019.1611008 ↗
28. Age and gender influence on maximal bite force and masticatory muscles thickness10.1016/j.archoralbio.2010.06.016 ↗
29. Occlusal forces during chewing–influences of biting strength and food consistency10.1016/0022-3913(81)90247-X ↗
30. Microstructural characterization and fracture behavior of a microhybrid and a nanofill composite10.1016/j.dental.2008.02.006 ↗
31. Academy of dental materials guidance—resin composites: part ii—technique sensitivity (handling, polymerization, dimensional changes)10.1016/j.dental.2017.08.188 ↗
32. Adhesive/dentin interface: the weak link in the composite restoration10.1007/s10439-010-9969-6 ↗
33. Degradation, fatigue, and failure of resin dental composite materials10.1177/154405910808700802 ↗
34. Are linear elastic material properties relevant predictors of the cyclic fatigue resistance of dental resin composites?10.1016/j.dental.2014.01.009 ↗
35. In vitro comparison of mechanical properties and degree of cure of bulk fill composites10.1007/s00784-012-0702-8 ↗
36. Influence of curing rate of resin composite on the bond strength to dentin10.2341/06-39 ↗
37. Effect of radiant exposure and UV accelerated aging on physico-chemical and mechanical properties of composite resins10.1590/1678-7757-2018-0075 ↗
38. Influence of light-polymerization modes on the degree of conversion and mechanical properties of resin composites: a comparative analysis between a hybrid and a nanofilled composite10.2341/07-81 ↗
39. Micro-rotary fatigue of tooth-biomaterial interfaces10.1016/j.biomaterials.2004.04.013 ↗
40. Finishing and polishing effects of multiblade burs on the surface texture of 5 resin composites: microhardness and roughness testing10.5395/rde.2019.44.e1 ↗
41. Effects of wet and dry finishing and polishing on surface roughness and microhardness of composite resins
42. Monomer release from resin based dental materials cured with led and halogen lights10.1055/s-0039-1697806 ↗
43. Effect of extraction media and storage time on the elution of monomers from four contemporary resin composite materials10.4103/0971-6580.128811 ↗
44. Water sorption and solubility of dental composites and identification of monomers released in an aqueous environment10.1046/j.1365-2842.2001.00802.x ↗
45. Hygroscopic and hydrolytic effects in dental polymer networks10.1016/j.dental.2005.05.005 ↗
46. The effect of esterase enzyme on aging dental composites10.1002/jbm.b.34313 ↗
47. Mutual influence of cholesterol esterase and pseudocholinesterase on the biodegradation of dental composites10.1016/j.biomaterials.2003.08.029 ↗
48. Filler leachability of composites stored in distilled water or artificial saliva10.1177/00220345960750091201 ↗
49. Filler particle leachability of experimental dental composites10.1034/j.1600-0722.2000.00919.x ↗
50. Changeability of oral cavity environment10.1055/s-0039-1698305 ↗
51. How much do resin-based dental materials release? A meta-analytical approach10.1016/j.dental.2011.05.001 ↗
52. Thermal cycling procedures for laboratory testing of dental restorations10.1016/S0300-5712(98)00037-2 ↗
53. Thermal cycling for restorative materials: does a standardized protocol exist in laboratory testing? A literature review10.1016/j.jmbbm.2013.09.013 ↗
54. Effects of critical thermal cycling on the flexural strength of resin composites10.2334/josnusd.57.137 ↗
55. Should my composite restorations last forever? Why are they failing?10.1590/1807-3107bor-2017.vol31.0056 ↗
56. Higher experience of caries and lower income trajectory influence the quality of restorations: a multilevel analysis in a birth cohort10.1016/j.jdent.2017.11.009 ↗
57. Clinical effectiveness of direct anterior restorations — a meta-analysis
58. Longevity of posterior composite restorations: a systematic review and meta-analysis10.1177/0022034514544217 ↗
59. Are there universal restorative composites for anterior and posterior teeth?10.1016/j.jdent.2013.08.016 ↗
60. Della. The slippery slope: critical perspectives on in vitro research methodologies10.1016/j.dental.2011.09.001 ↗
61. Fatigue behavior and crack initiation of CAD/CAM resin composite molar crowns10.1016/j.dental.2018.07.002 ↗
62. Fatigue resistance of CAD/CAM resin composite molar crowns10.1016/j.dental.2015.12.005 ↗
63. A critical perspective on mechanical testing of implants and prostheses10.1177/0022034515624445 ↗
64. A novel bite force recorder and maximal isometric bite force values for healthy young adults
65. Maximal bite force and its association with signs and symptoms of craniomandibular disorders in young Finnish non-patients10.3109/00016359509005982 ↗
66. A comparison of fatigue resistance of three materials for cusp-replacing adhesive restorations10.1016/j.jdent.2005.02.010 ↗
67. Survival, reasons for failure and clinical characteristics of anterior/posterior composites: 8-Year findings10.1590/0103-6440201802192 ↗
68. Load bearing capacity and Weibull characteristics of inlay-retained resin-bonded fixed dental prosthesis made of all-ceramic, fiber-reinforced composite and metal-ceramic after cyclic loading
69. Amalgam alternatives critically evaluated: effect of long-term thermomechanical loading on marginal quality, wear, and fracture behavior
70. Efficacy of direct restorative materials in proximal box elevation on the margin quality and fracture resistance of molars restored with CAD/CAM onlays10.2341/18-098-L ↗
71. Fracture load of 3D printed PEEK inlays compared with milled ones, direct resin composite fillings, and sound teeth10.1007/s00784-020-03216-5 ↗
72. Fracture force of CAD/CAM resin composite crowns after in vitro aging
73. Effect of proanthocyanidin mediated immediate and delayed dentin sealing on the strength of premolars restored with composite resin inlay10.4317/jced.55942 ↗
74. Comparison of fracture load and surface wear of microhybrid composite and ceramic occlusal veneers10.1111/jopr.13156 ↗
75. Direct bilayered biomimetic composite restoration: The effect of a cusp-supporting short fiber-reinforced base design on the chewing fracture resistance and failure mode of molars with or without endodontic treatment10.1016/j.jmbbm.2019.103554 ↗
76. Fracture strength of various types of large direct composite and indirect glass ceramic restorations10.2341/18-111-L ↗
77. Fatigue resistance of ultrathin CAD/CAM ceramic and nanoceramic composite occlusal veneers10.1016/j.dental.2019.07.006 ↗
78. Survival rate and load to failure of premolars restored with inlays: an evaluation of different inlay fabrication methods10.1016/j.prosdent.2018.03.019 ↗
79. In-vitro performance of CAD/CAM crowns with insufficient preparation design10.1016/j.jmbbm.2018.10.002 ↗
80. Effect of selective carious tissue removal on biomechanical behavior of class II bulk-fill dental composite restorations10.1016/j.dental.2018.05.014 ↗
81. Bonding efficacy and fracture pattern of adhesives submitted to mechanical aging with the rub & roll device
82. Influence of preparation, fitting, and cementation on the vitro performance and fracture resistance of CAD/CAM crowns10.1016/j.jdent.2017.07.006 ↗
83. fracture resistance and cusp deflection of lined or non-lined composite and glass hybrid restorations over residual demineralized dentin
84. Effect of immediate dentine sealing on the fracture strength of lithium disilicate and multiphase resin composite inlay restorations10.1016/j.jmbbm.2017.04.002 ↗
85. Bonding effectiveness of composite-dentin interfaces after mechanical loading with a new device (Rub&Roll)10.4012/dmj.2015-395 ↗
86. Accelerated fatigue resistance of thick CAD/CAM composite resin overlays bonded with light- and dual-polymerizing luting resins
87. Biomechanical behavior of extensively restored premolars: cusp deformation, marginal integrity, and fracture resistance
88. Influence of proximal box elevation on the marginal quality and fracture behavior of root-filled molars restored with CAD/CAM ceramic or composite onlays10.1007/s00784-014-1325-z ↗
89. Restoring nonvital premolars with composite resin onlays: effect of different fiber-reinforced composite layers on marginal adaptation and fracture load
90. Mechanical properties, shrinkage stress, cuspal strain and fracture resistance of molars restored with bulk-fill composites and incremental filling technique10.1016/j.jdent.2015.09.007 ↗
91. Stabilization effects of CAD/CAM ceramic restorations in extended MOD cavities
92. In vitro investigation on extensively destroyed vital teeth: Is fracture force a limiting factor for direct restoration?10.1111/joor.12219 ↗
93. Fracture strength and fracture patterns of root-filled teeth restored with direct resin composite restorations under static and fatigue loading10.2341/13-006-L ↗
94. The effect of mechanical loading on the cusp defection of premolars restored with direct and indirect techniques10.5005/jp-journals-10024-1491 ↗
95. Effect of resin cements and aging on cuspal deflection and fracture resistance of teeth restored with composite resin inlays
96. Comparative evaluation of fracture resistance of structurally compromised canals restored with different dowel methods10.1111/j.1532-849X.2011.00827.x ↗
97. Fracture resistance of composite resin restorations and porcelain veneers in relation to residual tooth structure in fractured incisors10.1111/j.1600-9657.2011.01037.x ↗
98. Fatigue resistance and microleakage of CAD/CAM ceramic and composite molar crowns10.1111/j.1532-849X.2011.00773.x ↗
99. Impact of adhesive surface and volume of luting resin on fracture resistance of root filled teeth10.1111/j.1365-2591.2010.01846.x ↗
100. Class II composite restorations: importance of cervical enamel in vitro10.2341/10-126-L ↗