journal article·2024-03Open access

Thermography and conversion of fast-cure composite photocured with quad-wave and laser curing lights compared to a conventional curing light

Halah Thanoon, Richard B. Price, David C. Watts

Dental Materials· Volume 40· Issue 3

Abstract

This study investigated effects of the different emittance-mode protocols from three light curing units (LCUs): (i) a Laser (Monet); (ii) a quad-wave (PinkWave); (iii) a conventional LED (Elipar S10) on the temperature rise (ΔT) and degree of conversion (DC) when photo-curing fast or conventional bulk-fill resin-based composites (RBC). The aim was to correlate ΔT and DC, and the radiant exposure delivered to RBC specimens. A 3D-printed resin mold of 4 mm depth was filled with two bulk-fill RBCs: Tetric PowerFill® (fast photo-polymerised composite) (TPF) or Tetric EvoCeram® Bulk-Fill (EVO). Three LCUs were used: (i) Monet laser for 1 s and 3 s (MONET-1 s, MONET-3 s); (ii) PinkWave quad-wave used for 3 s in Boost mode (PW-3 s) and for 20 s in standard mode (PW-20 s); (iii) Elipar S10 for 5 s (S10–5 s) and for 20 s in standard mode (S10–20 s). 2-dimensional temperature maps were obtained before, during and for 60 s after the LCU had turned off using a thermal imaging camera. Thermal changes were analysed at five depths: (0, 1, 2, 3, and 4 mm from the top surface of the RBC). The maximum temperature rise (Tmax) and the mean temperature rise (ΔT) were determined. Cylindrical-shaped specimens were prepared from each material using a stainless-steel split mold (4 × 4 mm) and light-cured with the same protocols. The DC was measured for 120 s and at 1 h after LCU had turned off using Fourier Transform Infrared Spectroscopy (FTIR). Data were analysed using Three-way ANOVA, One-way ANOVA, independent t-tests, and Tukey post-hoc tests (p < 0.05). Radiant exposures delivered by the various irradiation protocols were between 4.5–30.3 J/cm2. Short exposure times from MONET-1 s and PW-3 s delivered the lowest radiant exposures (4.5 and 5.2 J/cm2, respectively) and produced the lowest ΔT and DC. The longer exposure times in the standard modes of PW-20 s, S10–20 s, and MONET-3 s produced the highest Tmax, ΔT, and DC for both composites. The ΔT range among composites at different depths varied significantly (31.7–49.9 °C). DC of TPF ranged between 30–65% and in EVO between 15.3–56%. TPF had higher Tmax, ΔT for all depths and DC compared to EVO, across the LCU protocols (p < 0.05), except for PW-20 s and MONET-3 s. The coronal part of the restorations (1–2 mm) had the highest ΔT. There was a positive correlation between ΔT and DC at 4-mm depth after 120 s Longer, or standard, exposure times of the LCUs delivered greater radiant exposures and had higher DC and ΔT compared to shorter or high-irradiance protocols. The fast photo-polymerised RBC had comparatively superior thermal and conversion outcomes when it received a high irradiance for a short time (1–5 s) compared to the conventional Bulk-Fill RBC.
Source: openalex_inverted_index · Quality: baseline

Research context

OpenAlex topics: Dental materials and restorations · Conservation Techniques and Studies · Cultural Heritage Materials Analysis

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (49)

Show source-provided references
1. Sabbagh J., McConnell R. Bulk Fill Resin Composites in Dentistry: A Clinical Guide: Springer Nature; 2023.10.1007/978-3-031-16388-3 ↗
2. Bulk-fill resin-based composite restorative materials: a review10.1038/sj.bdj.2017.214 ↗
3. Outcomes of ultra-fast (3 s) photo-cure in a RAFT-modified resin-composite10.1016/j.dental.2020.02.007 ↗
4. Conversion kinetics of rapid photo-polymerized resin composites10.1016/j.dental.2020.07.008 ↗
5. Polymerization shrinkage and shrinkage stress development in ultra-rapid photo-polymerized bulk fill resin composites10.1016/j.dental.2021.02.012 ↗
6. Ivoclar Vivadent, Report, 2019 (Scientific documentation 3s PowerCure product system). 〈https://www.ivoclar.com/en_gb/products/equipment/3s-powercure-system〉. 2019.
7. Resin composite--state of the art.10.1016/j.dental.2010.10.020 ↗
8. What Happens When I Irradiate a BFC?
9. Price
10. VISTA A.P.E.X. PinkWave - light curing evolved. Accessed July 18, 2022. 〈https://vistaapex.com/pinkwave/〉. 2022.
11. Real-time multispectral transmission of hard tooth tissues and dental composites with their heating10.1016/j.dental.2023.08.174 ↗
12. The effect of specimen temperature on the polymerization of a resin-composite10.1016/j.dental.2011.06.004 ↗
13. Effectiveness of photopolymerization in composite resins using a novel 445-nm diode laser in comparison to LED and halogen bulb technology10.1007/s10103-018-2651-1 ↗
14. In vitro temperature changes in the pulp chamber caused by laser and Quadwave LED-light curing units10.1007/s10266-022-00780-y ↗
15. A Blinded Comparative Study of Four Commercially Available LEDs and a Laser Light Curing Device
16. A.M.D. Monet laser curing light. The 1 second revolution. Accessed 12 October, 2021. 〈https://www.amdlasers.com/pages/monet-laser-curing-light-intro〉. 2021.
17. Temperature excursions at the pulp–dentin junction during the curing of light-activated dental restorations10.1016/j.dental.2008.03.012 ↗
18. In vivo temperature rise in anesthetized human pulp during exposure to a polywave LED light curing unit10.1016/j.dental.2015.02.001 ↗
19. Temperature rise during polymerization of light-activated resin composites10.1046/j.1365-2842.1998.00336.x ↗
20. Pulp Response to Externally Applied Heat10.1016/0030-4220(65)90015-0 ↗
21. Clinical and histological evaluation of thermal injury thresholds in human teeth: a preliminary study10.1111/j.1365-2842.1997.tb00278.x ↗
22. LED curing lights and temperature changes in different tooth sites10.1155/2016/1894672 ↗
23. Polymerization kinetics and impact of post polymerization on the Degree of Conversion of bulk-fill resin-composite at clinically relevant depth10.1016/j.dental.2015.07.004 ↗
24. Post-cure depth of cure of bulk fill dental resin-composites10.1016/j.dental.2013.10.011 ↗
25. Effect of LED and Argon Laser on Degree of Conversion and Temperature Rise of Hybrid and Low Shrinkage Composite Resins10.2174/1874210601610010538 ↗
26. Hygroscopic and hydrolytic effects in dental polymer networks10.1016/j.dental.2005.05.005 ↗
27. Academy of Dental Materials guidance-Resin composites: Part II-Technique sensitivity (handling, polymerization, dimensional changes)10.1016/j.dental.2017.08.188 ↗
28. Correlation of parameters used to estimate monomer conversion in a light-cured composite10.1177/00220345880670060801 ↗
29. Irradiance uniformity and distribution from dental light curing units10.1111/j.1708-8240.2010.00318.x ↗
30. The effect of ultra-fast photopolymerisation of experimental composites on shrinkage stress, network formation and pulpal temperature rise10.1016/j.dental.2014.09.001 ↗
31. LED Curing Lights and Temperature Changes in Different Tooth Sites10.1155/2016/1894672 ↗
32. M.M.K.-P. Vollmer Infrared thermal imaging: Fundamentals, research and applications second edition.
33. In-vitro pulpal temperature increases when photo-curing bulk-fill resin-based composites using laser or light-emitting diode light curing units10.1111/jerd.13022 ↗
34. The effects of extended curing time and radiant energy on microhardness and temperature rise of conventional and bulk-fill resin composites10.1007/s00784-019-02807-1 ↗
35. In vitro pulp chamber temperature rise from irradiation and exotherm of flowable composites10.1111/j.1365-263X.2007.00899.x ↗
36. Temperature changes and hardness of resin-based composites light-cured with laser diode or light-emitting diode curing lights10.1007/s10266-022-00745-1 ↗
37. Effect of high-intensity curing lights on the polymerization of bulk-fill composites10.1016/j.dental.2018.06.005 ↗
38. Ability of short exposures from laser and quad-wave curing lights to photo-cure bulk-fill resin-based composites10.1016/j.dental.2023.01.007 ↗
39. Depth of cure of 10 resin-based composites light-activated using a laser diode, multi-peak, and single-peak light-emitting diode curing lights10.1016/j.jdent.2022.104141 ↗
40. Thermographic analysis of the effect of composite type, layering method, and curing light on the temperature rise of photo-cured composites in tooth cavities10.1016/j.dental.2017.07.007 ↗
41. Spatio-temporal temperature fields generated coronally with bulk-fill resin composites: A thermography study10.1016/j.dental.2021.06.008 ↗
42. Degree of conversion of nano-hybrid resin-based composites with novel and conventional matrix formulation10.1007/s00784-012-0736-y ↗
43. Wear and marginal breakdown of composites with various degrees of cure10.1177/00220345970760081401 ↗
44. Effect of energy density on properties and marginal integrity of posterior resin composite restorations10.1016/S0109-5641(03)00124-6 ↗
45. TetricPowerFill: Instructions for Use. 2021. Ivoclar Vivadent AG, Schaan/Liechtenstein.
46. β-allyl sulfones as addition–fragmentation chain transfer reagents: A tool for adjusting thermal and mechanical properties of dimethacrylate networks10.1021/ma501550b ↗
47. Characterizing surface viscoelastic integrity of ultra-fast photo-polymerized composites: Methods development10.1016/j.dental.2020.07.009 ↗
48. The effect of high-irradiance rapid polymerization on degree of conversion, monomer elution, polymerization shrinkage and porosity of bulk-fill resin composites10.1016/j.dental.2023.03.016 ↗
49. Evaluation of a Novel "Quad" wavelength Light Curing Unit10.4317/jced.59825 ↗