Polymerization of resin composite restorative materials: exposure reciprocity
Source abstract
Abstract
Objective To examine whether there is reciprocity between irradiation time and irradiance with regard to the mechanical properties of filled, resin composite restorative materials (RCs). Methods Four visible light-cured RCs, all of shade A3, were used: Heliomolar Radiopaque (HR) and Tetric Ceram (TC) (Ivoclar, Schaan, Liechtenstein), Filtek Z250 (FZ) (3M, St Paul, MN, USA) and Prodigy condensable (PR) (Kerr, Orange, CA, USA). Bar specimens (1.0 x 1.5 x 16.0 mm(3)) were cured at irradiances (I) ranging from 25-1500 mW/cm(2) and irradiation times (t) of 1-3000 s. Six specimens at 250 combinations of t and I were prepared and stored in artificial saliva of pH 6, at 37 degrees C for 7d before performing three-point bend tests for flexural strength (F), flexural modulus (E) and total energy to failure (W). Contour plots of property value vs. t and I on log scales were prepared. Results The contour plots showed three regions: unset at low I.t, a plateau corresponding to more or less full property development, and connecting ramp. The boundary between the plateau and the ramp suggests the minimum acceptable exposure. No practical lower limit to irradiance was detected, but there may be no benefit from increasing I beyond about 1,000 mW/cm(2). The slopes of the contours in the log-log plots provided a test of the hypothesis of reciprocity. These slopes were approximately -1.5 for HR, TC and PR; and approximately -1 for FZ, compared with the expected value of -1. The general hypothesis therefore fails. The existence of localized maxima in property values is further evidence of that failure, even for FZ. Significance Dentists may use any lamp, including LED sources, and attain satisfactory results providing irradiation time is long enough. Manufacturers ought to supply a graph indicating the minimum acceptable exposure for each product for specified curing lamps. Calculations based on total energy delivered to guide irradiation protocols are invalid and do not recognize product behavior.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Laser Applications in Dentistry and Medicine · Dental Erosion and Treatment
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (34)
Show source-provided references
1. Clinical guidelines for photocuring restorative resins10.14219/jada.archive.1995.0364 ↗
2. Factors affecting cure at depths within light-activated resin composite
3. In vitro evaluation of a curing radiometer as a predictor of polymerization depth
4. Depth of cure of visible light-cured resin: clinical simulation10.1016/0022-3913(86)90034-X ↗
5. Variability of lamp characteristics in dental curing lights10.1111/j.1708-8240.1989.tb00500.x ↗
6. Evaluating intensity output of curing lights in private dental offices10.14219/jada.archive.1994.0204 ↗
7. A survey of the efficiency of visible light curing units10.1016/S0300-5712(97)00004-3 ↗
8. Characteristics of visible-light-activated composite systems10.1038/sj.bdj.4805312 ↗
9. Curing light performance and polymerization of composite restorative materials10.1016/0300-5712(92)90136-Z ↗
10. Effects of light intensity on polymerization of light-cured composite resins10.4012/dmj.13.198 ↗
11. Effect of light exposure on fracture toughness and flexural strength of light-cured composites10.1016/S0109-5641(96)80042-X ↗
12. Water sorption and mechanical behaviour of cosmetic direct restorative materials in artificial saliva10.1016/S0109-5641(00)00097-X ↗
13. Calcium phosphate system in saliva-like media10.1039/ft9918701759 ↗
14. Heap · 1969
15. Dental materials
16. Polymerization kinetics of resin-based restorative materials10.1002/jbm.820170206 ↗
17. Odian · 1991
18. Polymerization depths of contemporary light-curing units using microhardness10.1111/j.1708-8240.2000.tb00243.x ↗
19. Characterization of resin composites polymerized with plasma arc curing units10.1016/S0109-5641(00)00025-7 ↗
20. Comparison between a plasma arc light source and convention halogen curing units regarding flexural strength, modulus, and hardness of photoactivated resin composites10.1007/s007840000063 ↗
21. Does the ‘Xenon Discharge Light’ reduce composite shrinkage?
22. Polymerization conversion of composite resins using different curing devices
23. Elution of TEGDMA and BisGMA from a resin and a resin composite cured with halogen or plasma light10.1034/j.1600-0722.2000.108004341.x ↗
24. Photoinitiation of polymerization10.1351/pac197749040431 ↗
25. Electron paramagnetic resonance study of free-radical kinetics in ultraviolet light-cured dimethacrylate copolymers10.1023/A:1008800626750 ↗
26. Electron spin-resonance studies of dental composites: effect of irradiation time, decay over time, pulverization, and temperature variations10.1016/0109-5641(92)90066-L ↗
27. Stability of radicals in cured composite materials10.1016/0109-5641(93)90064-W ↗
28. Contemporary issues in photocuring
29. Pulse activation: reducing resin-based composite contraction stress at the enamel cavosurface margins
30. Effect of stepped vs continuous light curing exposure on bond-strength to dentin
31. Effect of sequential vs continuous irradiation of light-cured resin composite on shrinkage, viscosity, adhesion, and degree of polymerization
32. Dental composite depth of cure with halogen and blue light emitting diode technology10.1038/sj.bdj.4800120 ↗
33. Dept of cure and compressive strength of dental composites cured with blue light emitting diodes (LEDs)10.1016/S0109-5641(99)00083-4 ↗
34. Light emitting diode (LED) and polymerization of dental composites: flexural properties and polymerization potential10.1016/S0142-9612(00)00029-6 ↗