Axial shrinkage-stress depends upon both C-factor and composite mass
Source abstract
Abstract
Objectives To measure and then mathematically model polymerization stress-dependence upon systematic variations of C-factor (bonded/unbonded area ratio) for the Bioman instrument [1], recording stress by free cantilever-beam deflection; compliance 1.5 microm/MPa. Methods A light-cured resin-composite (RZD103; Ivoclar) with 57% (v/v) 450 nm filler was studied. Facing surfaces: glass slab and steel rod-end, constituting the Bioman test chamber, being perpendicular to the measured axial stress-direction, were varied: (a) with rod-diameters (phi), from 1 to 10mm in 1mm increments (with 0.8mm gap height); and then (b) with gap heights (h) in 16 steps from 0.05 to 1.50mm (with phi=10mm). For each h and phi combination, giving C-factors ranging from 0.6 to 100, shrinkage-stress was recorded for 1h from start of 40s irradiation at 600 mW cm(-2) for photo-polymerization at 23 degrees C (n=3). Shrinkage-stress (S(sigma)) was plotted directly as functions of h, phi, and C and also per unit composite mass, (S(sigma)g(-1)). ANOVA and Tukey's statistics were applied. Results Series A-diameter variation; with C-factor increasing from 0.6 to 6, gave an exact exponential decrease in S(sigma) from 45 to 8 MPa. Series B-height variation; with C-factor increasing from 3 to 100, gave increasing S(sigma) from 1 to 8 MPa. Since composite mass played an equally dominant role, plots of stress-variations per unit composite mass, (S(sigma)g(-1)) separated these effects, confirming progressive off-axial stress-relief with increasing h. Significance (i) Values of h=0.8 and phi=10mm, recommended [1] for Bioman use, were confirmed as appropriate. Every lab instrument for measuring S(sigma) necessarily embodies specific C-factors and compliance values in the instrument design. (ii) Configuration (C) factor is recognized as an important parameter affecting manifestation of shrinkage-stress within restorative cavities and luting gaps. However, the restorative mass must equally be considered when translating shrinkage-science into specific clinical recommendations.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Laser Material Processing Techniques · Photopolymerization techniques and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (21)
Show source-provided references
1. Photo-polymerization shrinkage-stress kinetics in resin-composites: methods development10.1016/S0109-5641(02)00123-9 ↗
2. Relaxation of polymerization contraction stresses by flow in dental composites10.1177/00220345840630021001 ↗
3. Setting stress in composite resin in relation to configuration of the restoration10.1177/00220345870660110601 ↗
4. Effects of cavity configuration on composite restoration
5. The influence of configuration factors on cavity adaptation in compomer restorations10.4012/dmj.18.19 ↗
6. Polymerization contraction stress in thin resin composite layers as a function of layer thickness10.1016/S0109-5641(97)80115-7 ↗
7. Increased wall-to-wall curing contraction in thin bonded resin layers10.1177/00220345890680010701 ↗
8. Critical configuration analysis of four methods for measuring polymerization shrinkage strain of composites10.1016/j.dental.2003.11.002 ↗
9. The effects of adhesive thickness on polymerization contraction stress of composite10.1177/00220345000790030501 ↗
10. Influence of instrument compliance and specimen thickness on the polymerization shrinkage stress measurement of light-cured composites10.1016/j.dental.2006.10.003 ↗
11. Effect of composite type, light intensity, configuration factor and laser polymerization on polymerization contraction forces
12. Quantitative determination of stress reduction by flow in composite restorations10.1016/0109-5641(90)90023-8 ↗
13. Handling of mechanical stresses in composite restorations
14. Influence of cavity dimensions and their derivatives (volume and ’C’ factor) on shrinkage stress development and microleakage of composite restorations10.1016/j.dental.2005.11.010 ↗
15. A predictive formula of the contraction stress in restorative and luting materials attending to free and adhered surfaces, volume and deformation10.1016/S0109-5641(00)00077-4 ↗
16. Does an incremental filling technique reduce polymerization shrinkage stresses?10.1177/00220345960750030301 ↗
17. Polymerization shrinkage: effects of constraint and filling technique in composite restorations10.1016/S0109-5641(03)00098-8 ↗
18. A reappraisal of the incremental packing technique for light cured composite resins10.1046/j.0305-182X.2003.01073.x ↗
19. The influence of system compliance and sample geometry on composite polymerization shrinkage stress10.1002/jbm.10386 ↗
20. Marginal integrity related to bond strength and strain capacity of composite resin restorative systems10.1016/0022-3913(90)90291-J ↗
21. Cusp movement in premolars resulting from composite polymerization shrinkage10.1016/0109-5641(93)90096-9 ↗