journal article·2006-09

Influence of radiant exposure on contraction stress, degree of conversion and mechanical properties of resin composites

Fernanda C. Calheiros, Yoshio Kawano, Jeffrey W. Stansbury, Roberto R. Braga

Dental Materials· Volume 22· Issue 9
Publisher page

Abstract

Objective To verify the influence of radiant exposure (H) on contraction stress (CS), degree of conversion (DC) and mechanical properties of two restorative composites. Methods Filtek Z250 (3M ESPE) and Heliomolar (Ivoclar) were photoactivated with 6, 12, 24, or 36 J/cm2 at continuous irradiance of 600 mW/cm2. CS at 10 min was determined in a low compliance testing system. DC, flexural strength (FS), flexural modulus (FM) and Knoop microhardness (KHN) were measured after 24 h storage at 37 degrees C. KHN and DC measurements were conducted on the irradiated surface of 1mm thick disk-shaped specimens. Bar-shaped specimens were submitted to three-point bending to determine FS and FM. Data were analyzed by one-way ANOVA/Tukey's test (alpha = 0.05) separately for each composite. Results For Filtek Z250, no significant increase in CS was observed above 12 J/cm2. DC and FM were similar at all H values, while FS increased significantly between 6 and 24 J/cm2. KHN was significantly different among all H levels, except between 12 and 24 J/cm2. For Heliomolar, CS and KHN increased significantly with H, except between 24 and 36 J/cm2. DC, FM and FS did not vary, regardless of the radiant exposure. Significance Variables tested behaved differently. CS and KHN were more sensitive to increasing radiant exposures than the other properties evaluated. FS varied only for Filtek Z250, while, for both composites, DC and FM were not affected by different H values.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Oral health in cancer treatment · Laser Applications in Dentistry and Medicine

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (30)

Show source-provided references
1. Energy dependent polymerization of resin-based composite10.1016/S0109-5641(01)00069-0 ↗
2. How light irradiance and curing time affect monomer conversion in light-cured resin composites10.1111/j.0909-8836.2003.00082.x ↗
3. A primer on radiometry10.1016/j.dental.2004.10.002 ↗
4. Relationship between contraction stress and degree of conversion in restorative composites10.1016/j.dental.2004.03.003 ↗
5. Reduced light energy density decreases post-gel contraction while maintaining degree of conversion in composites10.1016/S0300-5712(97)00048-1 ↗
6. Photoinitiated polymerization of dimethacrylate oligomer: 2. Kinetic studies10.1016/S0032-3861(98)00380-2 ↗
7. Effect of light power density on development of elastic modulus of a model light-activated composite during polymerization10.1111/j.1708-8240.2001.tb00434.x ↗
8. Distribution of transient properties during polymerization of a light-initiated restorative composite10.1016/j.dental.2003.05.006 ↗
9. Effect of light intensity and exposure duration on cure of resin composite
10. Correlation between light intensity and exposure time on the hardness of composite resin10.1023/A:1008981907601 ↗
11. Comparison of flexural properties of composite restoratives using the ISO and mini-flexural tests10.1046/j.1365-2842.2003.01004.x ↗
12. Effect of excitation energy on dentine bond strength and composite properties10.1016/0300-5712(94)90202-X ↗
13. Contraction stress related to degree of conversion and reaction kinetics10.1177/0810114 ↗
14. Towards the elucidation of shrinkage stress development and relaxation in dental composites10.1016/j.dental.2004.05.002 ↗
15. Alternatives in polymerization contraction stress management10.1177/154411130401500306 ↗
16. Probing the origins and control of shrinkage stress in dental resin composites. II. Novel method of simultaneous measurement of polymerization shrinkage stress and conversion10.1002/jbm.b.30088 ↗
17. Effect of admixed high-density polyethylene (HDPE) spheres on contraction stress and properties of experimental composites10.1002/jbm.b.10019 ↗
18. Odian · 1991
19. Reaction kinetics and mechanics in photo-polymerized networks10.1016/j.dental.2004.10.003 ↗
20. Stability of radicals in cured composite materials10.1016/0109-5641(93)90064-W ↗
21. Post-irradiation polymerization of visible light-activated composite resin10.1177/00220345830620031201 ↗
22. Post-irradiation polymerization of different anterior and posterior visible light-activated resin composites10.1016/0109-5641(92)90104-K ↗
23. The effect of cure rate on the mechanical properties of dental resins10.1016/S0109-5641(01)00010-0 ↗
24. The effect of light intensity on double bond conversion and flexural strength of a model, unfilled dental resin10.1016/S0109-5641(02)00090-8 ↗
25. Smith · 1996
26. The effect of resin formulation on the degree of conversion and mechanical properties of dental restorative resins10.1002/jbm.820200111 ↗
27. Correlation between hardness and degree of conversion during the setting reaction of unfilled dental restorative resins10.1016/S0109-5641(85)80058-0 ↗
28. Effect of energy density on properties and marginal integrity of posterior resin composite restorations10.1016/S0109-5641(03)00124-6 ↗
29. Influence of pulse-delay curing on softening of polymer structures10.1177/00220345010800061801 ↗
30. Two-step curing: influence on conversion and softening of a dental polymer10.1016/S0109-5641(02)00091-X ↗