journal article·2007-03

Fracture resistance of implant-supported screw- versus cement-retained porcelain fused to metal single crowns: SEM fractographic analysis

Fernando Zarone, Roberto Sorrentino, Tonino Traini, Donato Di lorio, Sergio Caputi

Dental Materials· Volume 23· Issue 3
Publisher page

Abstract

Objectives The present in vitro study aimed at evaluating the fracture resistance of both implant-supported screw- and cement-retained porcelain fused to metal (PFM) single crowns. A scanning electron microscope (SEM) evaluation of the mode of failure of the specimens was also performed. Methods Forty PFM premolar-shaped identical single crowns were realized. The restorations were divided into two groups: cement-retained (group 1) and screw-retained (group 2) prostheses. Compressive loading tests and SEM fractographic analyses were performed. The data were statistically analysed by means of the Student's t-test, with a confidence interval of 95%. Results The mean fracture load value was 1657 (+/-725) N in group 1 and 1281 (+/-747) N in group 2; the statistical analysis pointed out no significant differences between the two groups (p=0.115). The mean work at maximum load value was 0.775 (+/-0.619) J in group 1 and 0.605 (+/-0.526) J in group 2; the statistical analysis pointed out no significant differences between the two groups (p=0.355). All the samples were affected by cohesive fractures of the porcelain. Screw-retained crowns showed microcracks at the level of the occlusal access to the screw and extensive fractures in the whole thickness of the ceramics. On the contrary, cement-retained restorations were affected by less wide paramarginal fractures of the porcelain. Significance A stronger implant-prosthetic connection was noticed in cemented restorations group than in screw-retained single crowns. Even though negatively influenced by the presence of the occlusal access to the screw, the metal-ceramics bond can be considered predictable in both the implant-prosthetic connection systems analysed.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Dental materials and restorations · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (50)

Show source-provided references
1. Failure and complications in 127 consecutively placed fixed partial prosthese supported by Branemark implants: from prosthetic treatment to first annual check up
2. Load transfer in screw- and cement-retained implant fixed partial denture designs
3. Screw-retained versus cement-retained implant-supported prostheses
4. Osseointegrated implants for single-tooth replacement: a prospective 5-year multicenter study
5. Cement-retained versus screw-retained implant restorations: Achieving optimal occlusion and esthetics in implant dentistry10.1016/S0022-3913(97)70203-8 ↗
6. Cemented versus screw-retained implant prostheses: which is better?
7. Cement-retained versus screw-retained implant restorations: a critical review
8. Cement-retained implant-supported fixed partial dentures: a 6-month to 3-year follow up
9. Telescopic prostheses for implants
10. Cemented single crowns on osseointegrated implants after 5 years: results from a prospective study on CeraOne
11. Ideal gingival form with computer-generated permanent healing abutments
12. Clinical results of osseointegrated implants supporting fixed prostheses in edentulous jaws
13. The long-term efficacy of currently used implants: a review and proposed criteria of success
14. Ten-year survival rates of fixed prostheses on four or six implants ad modum Branemark in full edentulism10.1034/j.1600-0501.1995.060405.x ↗
15. The relationship between covergence and retention of extracoronal retainers10.1111/j.1532-849X.1994.tb00132.x ↗
16. Retention of cemented implant-supported restorations10.1111/j.1532-849X.1997.tb00090.x ↗
17. Effect of abutment size and luting cement type on the uniaxial retention force of implant supported crowns10.1016/S0022-3913(00)70138-7 ↗
18. Retentiveness of dental cements used with metallic implant components
19. The lognitudinal clinical effectiveness of osseointegrated dental implants: The Toronto study Part III: problems and complications encountered10.1016/0022-3913(90)90177-E ↗
20. The edentulous predicament: a prospective study of the effectiveness of implant-supported fixed prostheses10.14219/jada.archive.1996.0031 ↗
21. Considerations for fabrication of implant-supported posterior restorations
22. Implant screw mechanics10.1016/S0011-8532(22)00606-1 ↗
23. The measurement of distortion: theoretical considerations10.1016/0022-3913(77)90173-1 ↗
24. The measurement of distortion: mathematical considerations10.1016/S0022-3913(78)80107-3 ↗
25. The measurement of distortion: concluding remarks10.1016/0022-3913(80)90190-0 ↗
26. Accuracy of implant impression techniques
27. Implants and components: entering the new millennium
28. An in vitro study on compensation of mismatch of screw versus cement-retained implant supported fixed prostheses10.1034/j.1600-0501.2000.011005448.x ↗
29. Theoretical analysis of the fatigue life of fixture screw in osseointegrated dental implants
30. The effect of eliminating implant/abutment rotational misfit on screw joint stability
31. Preload on oral implants after screw tightening fixed full prostheses: an in vivo study
32. Implant abutment screw rotations and preloads for four different screw materials and surfaces10.1067/mpr.2001.116230 ↗
33. Oral implant treatment in posterior partially edentulous jaws: a 5-year follow-up report
34. Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years
35. Implant reconstruction in the posterior mandible: a long-term retrospective study10.1016/S0022-3913(97)70085-4 ↗
36. Implant prosthodontics: current perspective and future directions
37. Copings on tooth and implant abutments for superstructure prostheses
38. Force transfer in implant dentistry: basic concepts and principles
39. Passivity of fit and marginal opening in screw- or cement-retained implant fixed partial denture designs
40. Osseointegrated bridge construction in partially edentulous patients
41. Failures and complications in 391 consecutively inserted fixed prostheses supported by Branemark implants in edentulous jaws
42. On the influence of superstructure connection on implant preload: a methodological and clinical study10.1034/j.1600-0501.1996.070107.x ↗
43. Use of luting agents with an implant system: Part I10.1016/0022-3913(92)90194-F ↗
44. The effect of surface roughness of crown preparation on retention of cemented castings10.1016/0022-3913(87)90043-6 ↗
45. Cement removal from restorations luted to titanium abutments with simulated subgingival margins10.1016/S0022-3913(97)70086-6 ↗
46. Occlusal contact wear of prosthodontic materials: an in vivo study10.3109/00016358809004762 ↗
47. Okeson · 1989
48. A comparison of the porcelain fracture resistance of screw-retained and cement-retained implant-supported metal–ceramic crowns10.1016/j.prosdent.2004.03.014 ↗
49. Yamamoto · 1985
50. Shillinburg · 1997