Clinical long-term retention of etch-and-rinse and self-etch adhesive systems in non-carious cervical lesions
Source abstract
Abstract
Objectives The aim of this study was to evaluate the clinical long-term retention to dentin of seven adhesive systems. Methods A total of 337 Class V restorations of three three-step etch-and-rinse, one two-step etch-and-rinse and three self-etch adhesive systems were placed in non-carious cervical lesions without intentional enamel involvement. The restorations were evaluated at baseline and then every 6 months during a 13 years follow-up. Dentin bonding efficiency was determined by the percentage of lost restorations. Results During the 13 years, 275 restorations could be evaluated. The cumulative loss rate at 13 years was 60.3%, with significant different failures rates for the different systems varying between 26.3 and 94.7%. Three materials fulfilled the ADA 18 months full acceptance criteria. Three systems showed already at 18 months or earlier catastrophical debonding rates. The annual failure rates for the three-step etch-and-rinse systems were: Allbond 2 4.1%, Clearfil LB 2.0% and Denthesive 7.3%. For the two-step etch-and-rinse Gluma 2000 6.5%, and for the self-etch systems ART 3.2%, Denthesive 2 5.7% and PUB 3 4.5% Conclusion A continuous degradation of the resin-dentin bond was observed for all bonding systems during the follow-up expressed by the increasing loss rates. A wide variation of dentin bonding effectiveness was seen between the systems independent to adhesion strategy.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Dental Erosion and Treatment · Dental Health and Care Utilization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (50)
Show source-provided references
1. Multi-step versus simplified enamel-dentin bonding systems
2. The clinical performance of adhesives10.1016/S0300-5712(96)00070-X ↗
3. Clinical evaluation of four dentin bonding agents in Class V abrasion lesions. A four year follow up10.1016/0109-5641(94)90040-X ↗
4. Do dentin bond strength tests serve a useful purpose?
5. Dentin bond durability after three years using a dentin bonding agent with and without priming10.1016/S0109-5641(96)80038-8 ↗
6. Effect of long-term water storage on dentin bonding
7. Long-term durability of dentin bonds made with a self-etching primer, in vivo10.1177/00220345990780041101 ↗
8. In vivo degradation of resin–dentin bonds produced by a self-etch and an etch-and-rinse adhesive10.1111/j.1600-0722.2005.00222.x ↗
9. Effect of HEMA on bonding to dentin
10. In vivo degradation of resin–dentin bonds in humans over 1 to 3 years10.1177/00220345000790060601 ↗
11. Clinical effectiveness of contemporary adhesives: a systematic review of current clinical trials10.1016/j.dental.2005.02.003 ↗
12. A clincial evaluation of anterior conventional, microfiller and hybrid composite resin fillings. A six year follow up study10.3109/00016358609094346 ↗
13. Siegel · 1956
14. Durability of new restorative materials in Class III cavities
15. Long term effect of dentin primers on enamel bond strength and marginal adaptation
16. A critical review of the durability of adhesion to tooth tissue: methods and results10.1177/154405910508400204 ↗
17. Microporous dentin zone beneath resin-impregnated layer
18. Nanoleakage: leakage within the hybrid layer
19. Resin-dentin interfacial ultrastructure and microtensile dentin bond strength after five-year water storage
20. SEM and TEM analysis of water degradation of human dentinal collagen10.1002/jbm.b.10560 ↗
21. Meta-analytical review of factors involved in dental adherence10.1177/00220345010800070301 ↗
22. Shear bond strength of new enamel etchants
23. Six month clinical evaluation of cervical lesions after acid etching and restoration
24. Clinical evaluation of Class V restorations using a total etch technique: 1-year results
25. Early clinical evaluation of four new bonding resins used for conservative restoration of cervical erosion lesions
26. Clinical evaluation of Class V restorations in non-retentive preparations
27. Clinical evaluation of three dentin treatments for Class V restorations
28. Two-year clinical evaluation of three dentin treatments
29. Two-year clinical evaluation of non-retentive Class V restorations
30. Clinical effectiveness of 12 adhesive systems in Class V non-retentive lesions
31. Clinical evaluation of five adhesive Class V systems
32. Clinical evaluation of five adhesive systems
33. Clinical success of Class V composite resin restorations without mechanical retention
34. Evaluation of the ART Bond dentin/enamel bonding system
35. Clinical performance of two dentin adhesives: 2-year results10.1111/j.1834-7819.1996.tb03141.x ↗
36. Three year clinical evaluation of the Clearfil Liner Bond system
37. Three year clinical effectiveness of four total-etch dentinal adhesive systems in cervical lesions
38. Three-year clinical evaluation of the Clearfil Liner Bond system
39. 2-year clinical evaluation of dentin bonding systems
40. Bond strength of six dental adhesives10.1016/0300-5712(94)90008-6 ↗
41. Shear bond strength required to prevent microleakage at the dentin/restoration interface
42. Clinical evaluation of a universal dentin bonding resin: preserving dentition through new materials
43. 3-year clinical evaluation of modified Gluma adhesive systems in cervical abrasion/erosion lesions
44. Clinical status of ten adhesive systems10.1177/00220345940730110401 ↗
45. 1-year clinical study of sclerotic vs non-sclerotic dentin bonding
46. Variables effecting resin bonding in dentin with Gluma 2000
47. Clinical and interfacial laboratory evaluation of a bonding agent in cervical abrasions
48. Clinical evaluation Prisma Universal Bond 3: one year results
49. 3-year clinical evaluation of LC resin-modified glass ionomer restorations
50. 3-year clinical evaluation of a dentin adhesive system in cervical abrasions