Crown pull-off test (crown retention test) to evaluate the bonding effectiveness of luting agents
Source abstract
Abstract
Objective The purpose of this review was to assess the influencing factors which affect laboratory tests that evaluate the effectiveness of luting agents on the retention of crowns in prepared dentin and - based on the results of the review - to propose a reasonable experimental setup. Materials and methods The database MEDLINE was systematically searched for laboratory methods that evaluated the effectiveness of luting agents by pulling off crowns from prepared extracted teeth. Results Eighteen studies were included into the systematic review. The studies varied largely with regard to tooth type (molars, premolars), number of specimens (9-25), stump height (3-6mm), convergence angle (4.8-33 degrees ), standardization and measurement of preparation surface, seating force (25-200N), artificial ageing, crosshead speed for tensile force and statistical analysis. The coefficient of variation of the test results varied from 3% to 100%. The most important influencing factors for the crown dislodgement were stump height and convergence angle as well as the luting agent. Panavia and RelyX Unicem generally produced the highest values followed by glass ionomer and zinc phosphate cements. When pooling and normalizing the data, the mean difference between glass ionomer and resin-based materials as well as between glass ionomer and zinc phosphate cements was statistically significant (Wilcoxon, p<0.05). Seating force, roughness, type of cutting bur and use of a desensitizing agent had all a negligible effect on the test results. Artificial ageing like thermocycling had no influence with glass ionomer cements whereas for resin-based cements thermocycling and prolonged water storage generated similar a failures stress than thermocycling alone. The comparison with clinical results did not reveal conclusive evidence that the results of the laboratory methods completely reflect the results of prospective clinical trials in conjunction with single crowns and fixed dental prostheses. A reasonable experimental setup includes: at least 20 specimens per group, stump height 3mm, convergence angle 20 degrees , thermocycling of specimens (5000x), avoidance of shearing forces during dislodgement and failure probability statistics (Weibull). Conclusions The results of pull-off tests with crowns that are cemented with luting agents varied largely and reflect only partially the results from clinical trials. The most influencing factors (standardized tooth preparation, avoidance of shearing stress during dislodgement of crown) had to be controlled to get meaningful results.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Dental Erosion and Treatment · Dental Health and Care Utilization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (64)
Show source-provided references
1. To what extent does the longevity of fixed dental prostheses depend on the function of the cement? Working Group 4 materials: cementation10.1111/j.1600-0501.2007.01442.x ↗
2. Dental luting agents: a review of the current literature10.1016/S0022-3913(98)70128-3 ↗
3. Adhesive luting of indirect restorations
4. The effect of preparation taper on the retention of cemented cast crowns under lateral fatigue loading10.1016/j.prosdent.2006.03.021 ↗
5. Microtensile bond strength of self-adhesive luting cements to ceramic
6. Micro-tensile bond strength of three luting resins to human regional dentin10.1016/j.dental.2005.02.009 ↗
7. Comparison of the flexural strength of five adhesive resin cements10.1111/j.1532-849X.2006.00151.x ↗
8. Influence of ceramic thickness and curing mode on the polymerization shrinkage kinetics of dual-cured resin cements10.1016/j.dental.2008.03.015 ↗
9. Effect of water on the physical properties of resin-modified glass ionomer cements10.1016/S0109-5641(99)00016-0 ↗
10. Effect of hygroscopic expansion on the push-out resistance of glass ionomer-based cements used for the luting of glass fiber posts10.1016/j.joen.2005.10.060 ↗
11. Clinical outcome of glass-fiber-reinforced crowns and fixed partial dentures: a three-year retrospective study
12. Meta-analytical review of factors involved in dentin adherence10.1177/00220345010800070301 ↗
13. The retention of complete crowns prepared with three different tapers and luted with four different cements10.1016/S0022-3913(03)00182-3 ↗
14. Influence of tooth surface roughness and type of cement on retention of complete cast crowns10.1016/S0022-3913(97)70223-3 ↗
15. Effect of tooth surface roughness on marginal seating and retention of complete metal crowns10.1016/S0022-3913(99)70241-6 ↗
16. The effect of die-spacing on crown retention
17. The effect of a resin-based sealer on crown retention for three types of cement10.1016/j.prosdent.2004.02.014 ↗
18. Effect of seating force, margin design, and cement on marginal seal and retention of complete metal crowns
19. Crown retention with use of different sealing systems on prepared dentine10.1046/j.1365-2842.2003.01180.x ↗
20. Effect of undercut placement on crown retention after thermocycling10.1111/j.1365-2842.1990.tb01410.x ↗
21. Retentive strength of all ceramic crowns after long-term water storage
22. Effect of dentin desensitizers and cementing agents on retention of full crowns using standardized crown preparations10.1016/S0022-3913(00)70042-4 ↗
23. Influence of low-viscosity liners on the retention of three luting materials
24. Crown retention with use of a 5% glutaraldehyde sealer on prepared dentin10.1016/S0022-3913(98)70074-5 ↗
25. The effect of resin desensitizing agents on crown retention10.14219/jada.archive.1997.0164 ↗
26. Effects of precementation desensitizing laser treatment and conventional desensitizing agents on crown retention
27. The effect of recementation on crown retention
28. Retention of zirconium oxide ceramic crowns with three types of cement10.1016/j.prosdent.2006.06.001 ↗
29. In vitro retentive strength of zirconium oxide ceramic crowns using different luting agents10.1016/j.prosdent.2005.04.011 ↗
30. Effect of preparation convergence on retention and seating discrepancy of complete veneer crowns10.1111/j.1365-2842.2004.01371.x ↗
31. Crown retention and cyclic loading (in vitro)
32. The relationship between abutment taper and resistance of cemented crowns to dynamic loading
33. A clinical study on abutment taper and height of full cast crown preparations
34. Abutment taper of full cast crown preparations by dental students in the UWI School of Dentistry
35. Systematic reviews: (1) The correlation between laboratory tests on marginal quality and bond strength. (2) The correlation between marginal quality and clinical outcome
36. Shear bond strength of resin cements to human dentin10.1016/j.dental.2007.11.021 ↗
37. Microtensile bond strength of luting materials to coronal and root dentin10.1111/j.1708-8240.2005.tb00107.x ↗
38. Bonding effectiveness of adhesive luting agents to enamel and dentin10.1016/j.dental.2005.12.002 ↗
39. Bond strength of glass ionomers to coronal and radicular dentin
40. Setting stress in composite resin in relation to configuration of the restoration10.1177/00220345870660110601 ↗
41. Influence of c-factor and layering technique on microtensile bond strength to dentin10.1016/j.dental.2003.08.001 ↗
42. Ten years’ clinical evaluation of three luting cements10.1016/0300-5712(95)00076-3 ↗
43. A split-mouth randomized clinical trial of single crowns retained with resin-modified glass-ionomer and zinc phosphate luting cements
44. Conventional FPDs. A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years10.1111/j.1600-0501.2004.01119.x ↗
45. A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II. Fixed dental prostheses10.1111/j.1600-0501.2007.01468.x ↗
46. Adhäsiv und konventionell befestigte Empress 1-Kronen
47. Retentive strengths of cast gold crowns using glass ionomer, compomer, or resin cement10.1016/S0022-3913(98)70164-7 ↗
48. Crown retention and flexural strength of eight provisional cements10.1016/S0022-3913(07)60145-0 ↗
49. The influence of luting cement on the probabilities of survival and modes of failure of cast full-coverage crowns10.1016/S0109-5641(00)00009-9 ↗
50. Clinical longevity of CAD/CAM generated Y-TZP posterior fixed partial dentures
51. A clinical evaluation of all-ceramic bridges placed in UK general dental practices: first-year results10.1038/sj.bdj.2008.937 ↗
52. Five-year evaluation of zirconia-based bridges in general practice: year-three results
53. Clinical long-term behavior of zirconia-based bridges (LAVA): five years results
54. The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: a prospective clinical pilot study10.1016/j.prosdent.2006.08.010 ↗
55. Clinical longevity of CAD/CAM generated Y-TZP posterior fixed partial dentures
56. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures
57. 24 month clinical evaluation of cercon zirconia all ceramic restorations
58. Prospective clinical evaluation of CerconTM premolar and molar FPDs
59. Outcome of posterior FPDs of veneered zirconia ceramic (Cercon)
60. Extended all-ceramic fixed partial dentures – clinical performance after one year
61. Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs)10.1007/s00784-009-0249-5 ↗
62. Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results
63. All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study10.1111/j.1365-2842.2004.01437.x ↗
64. Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs