Variation of depth of cure and intensity with distance using LED curing lights
Source abstract
Abstract
Objectives The purpose of the study was to determine the correlation between intensity of light-emitting diode (LED) and tungsten-halogen light sources, and depth of cure of a resin composite at different distances. Methods Four LED curing lights (Flashlite 1001, Freelight 2, Smartlite IQ and Ultralume 5) and one tungsten halogen (Optilux 501, with 8 and 11 mm tips) were evaluated. Intensity was measured according a modified ISO Standard 10650 at distances of 0, 2, 4, 6, 8, 10 mm between the light tip and detector. Depth of cure (DOC) of TPH Spectrum shade A2 was measured according to the international standard ISO 4049 at the same distances. Results For all lights, intensity decreased as distance increased. The authors documented a logarithmic correlation between intensity and distance for all lights except the Smartlite IQ, Ultralume 5 and the Optilux 501 with the 11 mm tip, which showed a linear relationship between intensity and distance. All lights demonstrated a logarithmic correlation between intensity and DOC, and a linear correlation between DOC and distance. Smartlite IQ and Optilux 501 (11 mm tip) also had the least reduction in intensity and DOC at 10 mm. Significance Clinicians often an experience difficulty placing the light tip close to the resin surface when curing resin composites. While both intensity and DOC decrease with increasing distance, the relationship between these factors and distance may not be similar for all lights and may depend on the characteristics of individual lights.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Anatomy and Medical Technology · Photopolymerization techniques and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (21)
Show source-provided references
1. Variability of lamp characteristics in dental curing lights10.1111/j.1708-8240.1989.tb00500.x ↗
2. Influence of a gluteraldehyde disinfecting solution on curing light effectiveness
3. Irradiance of visible light-curing units and voltage variation effects10.14219/jada.archive.1987.0252 ↗
4. The effect of distance from light source on light intensity from curing lights
5. Effect of light exposure on fracture toughness and flexural strength of light-cured composites10.1016/S0109-5641(96)80042-X ↗
6. Shrinkage stress relaxation using pulsed curing
7. Effect of distance on the power density from two light guides10.1111/j.1708-8240.2000.tb00241.x ↗
8. Decrease in power output of new light-emitting diode (LED) curing devices with increasing distance to filling surface
9. Effect of air, dentin and resin-based composite thickness on light intensity reduction
10. An assessment of visible-light polymerizing sources10.1111/j.1365-2842.1986.tb00653.x ↗
11. Curing light performance and polymerization of composite restorative materials10.1016/0300-5712(92)90136-Z ↗
12. International Organization for Standardization. ISO 10650:2004. Dentistry—powered polymerization activators. Geneva, Switzerland: International Organization for Standardization; 2004.
13. Effect of aperture size on irradiance of LED curing units10.1016/j.dental.2004.01.002 ↗
14. International Organization for Standardization. ISO No. 4049:2000. Dentistry—polymer-based filling, restorative and luting materials. Geneva, Switzerland: ISO; 2000.
15. Curing-light intensity and depth of cure of resin-based composites tested according to international standards10.14219/jada.archive.2002.0200 ↗
16. Effect of light-tip distance on polymerization of resin composite
17. Performance of two blue light-emitting-diode dental curing units with distance and irradiation-time10.1016/S0109-5641(03)00070-8 ↗
18. Effects of curing tip distance on light intensity and composite resin microhardness
19. Reliability of three dental radiometers
20. Visible-light curing units: correlation between depth of cure and distance between exit window and resin surface10.3109/00016359709115410 ↗
21. Light distribution and divergence from curing light guides