Acoustic emission analysis of fiber-reinforced composite in flexural testing
Source abstract
Abstract
Objectives The aim of this study was to examine the emission of acoustic signals from six commercially available fiber-reinforced composites (FRC) used in the frameworks of fixed partial dentures in material bending. Methods FRC test specimens were made of six commercially available fiber products of polyethylene or glass and five light-curing resins. FRC test specimens were polymerized with a hand light-curing unit or with a light-curing oven. The flexural test for determination of ultimate flexural strength of test specimens (n = 6) was based on the ISO 10477 standard after the specimens were stored in air or in water for two weeks. The acoustic emission (AE) signals were monitored during three-point loading test of the test specimens using a test with increasing loading levels until the specimens fractured. Results Generally, stress level required for the AE activity initiation ranged from 107 MPa (Ribbond) to 579 MPa (everStick). The ultimate flexural strength of FRC specimens were higher, ranging from 132 to 764 MPa, being highest with everStick and Vectris FRC, and lowest with Ribbond FRC. ANOVA showed a statistically significant difference between the initiation of AE activity and the ultimate flexural strength according to the brand (p < 0.001) storing conditions (p < 0.001) and polymerization procedure (p < 0.001). AE activity and ultimate flexural strength correlated significantly (p < 0.010, r = 0.887). Significance The result of this study suggested that AE activity in FRC specimens started at a 19-32% lower stress level than occurred at final fracture.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Dental Health and Care Utilization · Dental Erosion and Treatment
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (36)
Show source-provided references
1. The use of continuous fiber reinforcement in dentistry10.1016/0109-5641(92)90083-O ↗
2. Longitudinal clinical evaluation of fiber-reinforced composite fixed partial dentures: a pilot study10.1016/0022-3913(94)90249-6 ↗
3. Pre-impregnated, fiber-reinforced polymer fixed prostheses. Part 1: preimpregnated, fiber-reinforced prostheses. Part 1. Basic rationale and complete-coverage and intracoronal fixed partial denture designs
4. Pre-impregnated, fiber-reinforced polymer fixed prostheses. Part 2. Direct applications- splints and fixed partial dentures
5. Prosthodontic treatment with a glass fiber-reinforced resin-bonded partial denture: a clinical report10.1016/S0022-3913(99)70145-9 ↗
6. Experience of using glass fibers with multiphase acrylic resin systems
7. Experimental design of FPD made All-ceramics and fiber-reinforced composite10.1016/S0109-5641(00)00002-6 ↗
8. Flexural properties of fiber reinforced composite using a vacuum/pressure or a manual adaptation manufacturing process10.1016/S0300-5712(00)00031-2 ↗
9. The effect of glass fiber reinforcement on the fracture resistance of provisional fixed partial denture10.1016/S0022-3913(98)70204-5 ↗
10. Flexural properties of acrylic resin polymers reinforced with unidirectional and woven glass fibers10.1016/S0022-3913(99)70276-3 ↗
11. Strength and interfacial adhesion of FRC-tooth system
12. Resin-bonded, glass fiber-reinforced composite fixed partial dentures: a clinical study10.1067/mpr.2000.109782 ↗
13. Biomechanical aspects and material properties
14. Current design factors in fiber reinforced composite fixed partial dentures
15. An evaluation of acoustic emission from fiber-reinforced composites10.1007/BF00550247 ↗
16. Composite characterization techniques
17. Testing fiber composites with acoustic emission monitoring
18. A review: acoustic emission, a tool for composite-materials studies10.1007/BF02319949 ↗
19. Pollock · 1989 · vol. 17
20. In vitro study of fracture strength and marginal adaption of fibre-reinforced adhesive fixed partial inlay dentures10.1016/S0300-5712(98)00036-0 ↗
21. The influence of short-term water storage on the flexural properties of unidirectional glass fiber-reinforced composites10.1016/S0142-9612(01)00355-6 ↗
22. Flexural properties of the bulk fiber-reinforced composite DC-Tell used in fixed partial dentures
23. The flexural properties of fiber-reinforced composite with light-polymerized polymer matrix
24. The effect of placement and quantity of glass fibers on the fracture resistance of interim fixed partial dentures
25. 1992
26. Reinforcement of poly (methyl methacrylate) with ultra-high-modulus polyethylene fibre10.1016/0300-5712(92)90012-2 ↗
27. Acrylic resin reinforced with chopped high performance polyethylene fiber-properties and denture construction10.1016/0109-5641(93)90089-9 ↗
28. Effect of polyethylene fiber reinforcement on the strength of denture base resins polymerised by microwave energy10.1016/0022-3913(94)90296-8 ↗
29. A review of fiber-reinforced denture base resins10.1111/j.1532-849X.1996.tb00511.x ↗
30. Fiber reinforced composites-in vitro behaviour
31. Characteristics of damage and fracture process of carbon fiber reinforced plastic under loading–unloading test by using AE method10.1016/S0921-5093(97)00226-8 ↗
32. An acoustic-emission characterization of the failure modes in polymer-composite materials10.1016/S0266-3538(98)00013-X ↗
33. On the use of acoustic emission to investigate damage mechanisms in glass-fibre-reinforced polypropylene10.1016/0266-3538(94)90171-6 ↗
34. Water sorption, solubility and effect of post curing of glass fibre reinforced polymers10.1016/S0142-9612(99)00003-4 ↗
35. Acoustic emission from a notched glass-fibre-reinforced polymer in bending10.1088/0022-3727/9/13/012 ↗
36. Transverse strength and acoustic emission characteristics of commercial denture base resins