journal article·2015-11

Fatigue induced changes in conical implant–abutment connections

Kai Blum, Wolfram Wiest, Christian Fella, Andreas Balles, Jonas Dittmann, Alexander Rack, Dominik Maier, Ralf Thomann, Benedikt Christopher Spies, Ralf Joachim Kohal, Simon Zabler, Katja Nelson

Dental Materials· Volume 31· Issue 11
Publisher page

Abstract

Objectives Based on the current lack of data and understanding of the wear behavior of dental two-piece implants, this study aims for evaluating the microgap formation and wear pattern of different implants in the course of cyclic loading. Methods Several implant systems with different conical implant-abutment interfaces were purchased. The implants were first evaluated using synchrotron X-ray high-resolution radiography (SRX) and scanning electron microscopy (SEM). The implant-abutment assemblies were then subjected to cyclic loading at 98N and their microgap was evaluated after 100,000, 200,000 and 1 million cycles using SRX, synchrotron micro-tomography (μCT). Wear mechanisms of the implant-abutment connection (IAC) after 200,000 cycles and 1 million cycles were further characterized using SEM. Results All implants exhibit a microgap between the implant and abutment prior to loading. The gap size increased with cyclic loading with its changes being significantly higher within the first 200,000 cycles. Wear was seen in all implants regardless of their interface design. The wear pattern comprised adhesive wear and fretting. Wear behavior changed when a different mounting medium was used (brass vs. polymer). Significance A micromotion of the abutment during cyclic loading can induce wear and wear particles in conical dental implant systems. This feature accompanied with the formation of a microgap at the IAC is highly relevant for the longevity of the implants.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental Implant Techniques and Outcomes · Orthopaedic implants and arthroplasty · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (44)

Show source-provided references
1. Implants and components. Entering the new millennium
2. Dynamic fatigue resistance of implant–abutment junction in an internally notched morse-taper oral implant: influence of abutment design10.1111/j.1600-0501.2004.01023.x ↗
3. Dynamic fatigue properties of the dental implant–abutment interface: joint opening in wide-diameter versus standard-diameter hex-type implants10.1067/mpr.2001.115250 ↗
4. Fatigue resistance of two implant/abutment joint designs10.1067/mpr.2002.129384 ↗
5. In-vitro corrosion and wear of titanium alloys in the biological environment10.1016/0142-9612(96)00029-4 ↗
6. Fayeulle · Tribol Transact · 1993 · 26710.1080/10402009308983158 ↗
7. An in vitro evaluation of the strength of a 1-piece and 2-piece conical abutment joint in implant design10.1034/j.1600-0501.2000.011005458.x ↗
8. Bite forces and their resultants during forceful intercuspal clenching in humans10.1016/j.jbiomech.2009.03.040 ↗
9. Measurement of masticatory forces and implant loads: a methodologic clinical study
10. In vitro evaluation of the strength of the conical implant-to-abutment joint in two commercially available implant systems10.1016/S0022-3913(00)70016-3 ↗
11. Abutment rotational displacement of external-hexagon implant system under lateral cyclic loading10.1111/j.1708-8208.2006.00006.x ↗
12. Performance of conical abutment (Morse Taper) connection implants: a systematic review10.1002/jbm.a.34709 ↗
13. Early loading of surface modified implants in the posterior mandible – 5 year results of an open prospective non-controlled study10.1111/j.1600-051X.2011.01816.x ↗
14. Cumulative survival rate and complication rates of single-tooth implant; focused on the coronal fracture of fixture in the internal connection implant10.1111/joor.12065 ↗
15. A meta-analysis of prosthodontic complication rates of implant-supported fixed dental prostheses in edentulous patients after an observation period of at least 5 years
16. Prosthetic complications with dental implants: from an up-to-8-year experience in private practice
17. A systematic review of the 5-year survival and complication rates of implant-supported single crowns10.1111/j.1600-0501.2007.01453.x ↗
18. Peri-implant health and disease. A systematic review of current epidemiology
19. The epidemiology of peri-implantitis10.1111/j.1600-0501.2012.02541.x ↗
20. The pathology of bone tissue during peri-implantitis10.1177/0022034514559128 ↗
21. Wear at the titanium-zirconia implant–abutment interface: a pilot study
22. Microbiological assessment of the implant–abutment interface in different connections: cross-sectional study after 5 years of functional loading
23. Wear at the titanium-titanium and the titanium-zirconia implant–abutment interface: a comparative in vitro study10.1016/j.dental.2012.08.008 ↗
24. Fretwurst T, Buzanich G, Nahles S, Woelber JP, Riesemeier H, Nelson K. Metal elements in tissue with dental peri-implantitis. A pilot study. Clin Oral Implants Res. (In press).
25. Foreign bodies associated with peri-implantitis human biopsies10.1902/jop.2014.140363 ↗
26. An in vitro pilot study of abutment stability during loading in new and fatigue-loaded conical dental implants using synchrotron-based radiography10.11607/jomi.2748 ↗
27. Parameters determining micromotion at the implant abutment interface10.11607/jomi.3762 ↗
28. In vitro synchrotron-based radiography of micro-gap formation at the implant-abutment interface of two-piece dental implants10.1107/S0909049510001834 ↗
29. Fatigue induced deformation of taper connections in dental titanium implants10.3139/146.110666 ↗
30. Quantitative studies on inner interfaces in conical metal joints using hard X-ray inline phase contrast radiography10.1063/1.3495966 ↗
31. 2008
32. Synchrotron microcomputed tomography of the mature bovine dentinoenamel junction10.1016/j.jsb.2007.10.001 ↗
33. Alumina reinforced zirconia implants: effects of cyclic loading and abutment modification on fracture resistance10.1016/j.dental.2014.12.013 ↗
34. Young's modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements10.1016/0021-9290(93)90042-D ↗
35. Changes in the abutment-implant interface in Morse taper implant connections after mechanical cycling: a pilot study10.11607/jomi.3113 ↗
36. A pilot study of joint stability at the zirconium or titanium abutment/titanium implant interface10.11607/jomi.3116 ↗
37. Dental implants with conical implant–abutment interface: influence of the conical angle difference on the mechanical behavior of the implant10.11607/jomi.2775 ↗
38. Cyclic loading of implant-supported prostheses: changes in component fit over time10.1067/mpr.2003.71 ↗
39. Assessment of lipopolysaccharide microleakage at conical implant–abutment connections10.1007/s00784-011-0646-4 ↗
40. 2003
41. The issue of corrosion in dental implants: a review
42. Wear behavior of tetragonal zirconia polycrystal versus titanium and titanium alloy10.1088/1748-6041/6/2/021001 ↗
43. Fretting wear of materials – methodological aspects of research
44. 2001