Bond strength tests of dental adhesive systems and their correlation with clinical results – A meta-analysis
Source abstract
Abstract
Objective To evaluate the variability of bond strength test results of adhesive systems (AS) and to correlate the results with clinical parameters of clinical studies investigating cervical restorations. Materials and methods Regarding the clinical studies, the internal database which had previously been used for a meta-analysis on cervical restorations was updated with clinical studies published between 2008 and 2012 by searching the PubMed and SCOPUS databases. PubMed and the International Association for Dental Research abstracts online were searched for laboratory studies on microtensile, macrotensile and macroshear bond strength tests. The inclusion criteria were (1) dentin, (2) testing of at least four adhesive systems, (3) same diameter of composite and (4) 24h of water storage prior to testing. The clinical outcome variables were retention loss, marginal discoloration, detectable margins, and a clinical index comprising the three parameters by weighing them. Linear mixed models which included a random study effect were calculated for both, the laboratory and the clinical studies. The variability was assessed by calculating a ratio of variances, dividing the variance among the estimated bonding effects obtained in the linear mixed models by the sum of all variance components estimated in these models. Results Thirty-two laboratory studies fulfilled the inclusion criteria comprising 183 experiments. Of those, 86 used the microtensile test evaluating 22 adhesive systems (AS). Twenty-seven used the macrotensile test with 17 AS, and 70 used the macroshear test with 24 AS. For 28 AS the results from clinical studies were available. Microtensile and macrotensile (Spearman rho=0.66, p=0.007) were moderately correlated and also microtensile and macroshear (Spearman rho=0.51, p=0.03) but not macroshear and macrotensile (Spearman rho=0.34, p=0.22). The effect of the adhesive system was significant for microtensile and macroshear (p < 0.001) but not for macrotensile. The effect of the adhesive system could explain 36% of the variability of the microtensile test, 27% of the macrotensile and 33% of the macroshear test. For the clinical trials, about 49% of the variability of retained restorations could be explained by the adhesive system. With respect to the correlation between bond strength tests and clinical parameters, only a moderate correlation between micro- and macrotensile test results and marginal discoloration was demonstrated. However, no correlation between these tests and a retention loss or marginal integrity was shown. The correlation improved when more studies were included compared to assessing only one study. Significance The high variability of bond strength test results highlights the need to establish individual acceptance levels for a given test institute. The weak correlation of bond-strength test results with clinical parameters leads to the conclusion that one should not rely solely on bond strength tests to predict the clinical performance of an adhesive system but one should conduct other laboratory tests like tests on the marginal adaptation of fillings in extracted teeth and the retention loss of restorations in non-retentive cavities after artificial aging.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Dental Erosion and Treatment
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (36)
Show source-provided references
1. Adhesive bonding of various materials to hard tooth tissues. I. Methods of determining bond strength10.1177/00220345650440041501 ↗
2. Standardizing laboratory adhesion tests
3. Correlation of in vivo and in vitro performance of adhesive restorative materials: a report of the ASC MD156 task group on test methods for the adhesion of restorative materials10.1016/0109-5641(91)90049-5 ↗
4. Adhesion testing of dentin bonding agents: a review
5. Do dentin bond strength tests serve a useful purpose?
6. The validity of reported tensile bond strength utilizing non-standardized specimen surface areas. An analysis of in vitro studies
7. Methods used in dentine bonding tests: an analysis of 102 investigations on bond strength
8. Adhesion to tooth structure: a critical review of macro test methods10.1016/j.dental.2009.11.150 ↗
9. Adhesion to tooth structure: a critical review of “micro” bond strength test methods10.1016/j.dental.2009.11.155 ↗
10. Direct comparison of the bond strength results of the different test methods: a critical literature review10.1016/j.dental.2009.12.002 ↗
11. Testing adhesion of direct restoratives to dental hard tissue – a review
12. In-vitro orthodontic bond strength testing: a systematic review and meta-analysis10.1016/j.ajodo.2009.12.021 ↗
13. Meta-analytical review of parameters involved in dentin bonding10.1177/0022034511431251 ↗
14. Correlation between microtensile bond strength data and clinical outcome of Class V restorations10.1016/j.dental.2010.09.005 ↗
15. Relationship between bond-strength tests and clinical outcomes10.1016/j.dental.2009.11.148 ↗
16. Clinical performance of cervical restorations – a meta-analysis10.1016/j.dental.2010.06.003 ↗
17. Microtensile and tensile bond strength of single-bottle adhesives: a new test method10.1046/j.1365-2842.2003.01227.x ↗
18. Meta-analytical review of factors involved in dentin adherence10.1177/00220345010800070301 ↗
19. Effect of operator variability on dentin adhesion: students vs dentists10.4012/dmj.17.51 ↗
20. Effect of operator variability on dentin bond strength of two-step bonding systems
21. Shear bond strength of one 4th and two 7th generation bonding agents when used by operators with different bonding experience
22. Bond strength test: role of operator skill10.1111/j.1834-7819.2008.00024.x ↗
23. Influence of operator experience on in vitro bond strength of dentin adhesives
24. In vitro comparison of dentin bonding systems: effect of testing method and operator
25. Shear bond strength of one etch-and-rinse and five self-etching dental adhesives when used by six operators10.1080/00016350802220088 ↗
26. Bonding to dentin achieved by general practitioners
27. Pooling of dentin microtensile bond strength data improves clinical correlation
28. Eight-year clinical evaluation of fired ceramic inlays
29. Prediction of secondary caries around tooth-colored restorations: a clinical and microbiological study10.1177/00220345960750120501 ↗
30. Long-term bonding to eroded dentin requires superficial bur preparation10.1007/s00784-011-0650-8 ↗
31. Clinical effectiveness of direct class II restorations – a meta-analysis
32. An assessment of stress analyses in the theory of abfraction
33. Epidemiological evaluation of the multifactorial aetiology of abfractions10.1111/j.1365-2842.2006.01532.x ↗
34. Recommendations for conducting controlled clinical studies of dental restorative materials (Science Committee Project 2/98 – FDI World Dental Federation)
35. The semi-quantitative evaluation of restorations (SQUACE) – a tool to increase sensitivity
36. Clinical relevance of tests on bond strength, microleakage and marginal adaptation10.1016/j.dental.2012.07.158 ↗