The span length and cross-sectional design affect values of strength
Source abstract
Abstract
Objectives The aim of this study was to determine experimentally flexural strength and flexural modulus of fiber-reinforced composite (FRC) with different cross-sectional designs and diameters and tested with different span lengths. Methods Continuous FRC test specimens (n = 6) were made with two different cross-sectional designs, namely circular and rectangular. The resin matrix of FRC was polymerized with a hand light-curing unit followed by a light-curing oven polymerization. Three-point flexural test for determination of ultimate flexural strength and flexural modulus of the dry test specimens was made with different span lengths for rectangular specimens and diameters for circular specimens. Thus, the span length/diameter ratio (L/D) was changed. Results Flexural strength and flexural modulus of specimens with rectangular cross-section varied from 540 to 792 MPa and 9.8 to 20.3 GPa being the highest with the group of the 20 mm span length and the lowest with the group of the 10 mm span length. Flexural strength and flexural modulus of circular cross-section specimens varied from 847 to 1286 MPa and 19.9 to 36.6 GPa being the highest with 1.5 mm cross-section and the lowest with 2.8 mm cross-section. Significance It was concluded, that by increasing the L/D ratio, the flexural strength and flexural modulus values in MPa increased and the maximum fracture load values in N decreased. Reporting the L/D ratio is essential for interpretation of flexural strength and flexural modulus values of small size test specimens.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Mechanical Behavior of Composites · Natural Fiber Reinforced Composites · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (20)
Show source-provided references
1. The use of continuous fiber reinforcement in dentistry10.1016/0109-5641(92)90083-O ↗
2. Flexural properties of acrylic resin polymers reinforced with unidirectional and woven glass fibers10.1016/S0022-3913(99)70276-3 ↗
3. The influence of short-term water storage on the flexural properties of unidirectional glass fiber-reinforced composites10.1016/S0142-9612(01)00355-6 ↗
4. Acoustic emission analysis of fiber-reinforced composite in flexural testing10.1016/S0109-5641(03)00108-8 ↗
5. International Standards Organisation · 1992
6. ASTM D 790-98, · 1999
7. Carbon fiber reinforced root canal posts. Mechanical and cytotoxic properties10.1111/j.1600-0722.1996.tb00149.x ↗
8. Optimization of the three-point bend test for fracture energy measurement10.1007/BF00566268 ↗
9. Screening of matrices and fibers for reinforced thermoplastics intended for dental applications10.1002/jbm.820280205 ↗
10. Shear in flexure of fiber composites with different end supports10.1177/154405910308200404 ↗
11. Flexural properties of fiber reinforced root canal posts10.1016/S0109-5641(03)00065-4 ↗
12. Kinking and tensile, compressive and interlaminar shear failure in carbon-fibre-reinforced plastic beams tested in flexure10.1007/BF00738635 ↗
13. Measurement of the elastic modulus of fibre-reinforced composites used as orthodontic wires10.1007/BF00121091 ↗
14. Myrphy · 1998
15. Compositional and weave pattern analyses of glass fibers in dental polymer fiber composites10.1111/j.1532-849X.1998.tb00200.x ↗
16. Strength and elastic modulus of fiber-reinforced composites used for fabricating FPDs
17. Deng S, Ye L, Mai Y-W. Influence of fibre cross-sectional aspect ratio on mechanical properties of glass fibre/epoxy composites 1. Tensile and flexure behaviour. Composites. Sci. Technol. 1999;59:1331–9.10.1016/S0266-3538(98)00168-7 ↗
18. Geometric and material parameters of nickel-titanium and beta titanium orthodontic arch wire alloy10.1016/S0109-5641(87)80035-0 ↗
19. The influence of fibre placement and position on the efficiency of reinforcement of fibre reinforced composite bridgework10.1046/j.1365-2842.2001.00792.x ↗
20. Effect of fiber position and orientation on fracture load of fiber-reinforced composite10.1016/j.dental.2003.12.003 ↗