journal article·2014-03

Glass ionomer cements: Effect of strontium substitution on esthetics, radiopacity and fluoride release

S. Shahid, U. Hassan, R.W. Billington, R.G. Hill, P. Anderson

Dental Materials· Volume 30· Issue 3
Publisher page

Abstract

Objective SrO and SrF2 are widely used to replace CaO and CaF2 in ionomer glasses to produce radiopaque glass ionomer cements (GIC). The purpose of this study was to evaluate the effects of this substitution on release of ions from GIC as well as its effect on esthetics (translucency) and radiopacity. Materials and methods Cements were produced from ionomer glasses with varying content of Sr, Ca and F. The cements were stored in dilute acetic acid (pH 4.0) for up to 7 days at 37°C. Thereafter, the cements were removed and the solution was tested for F(-), Sr(2+), Ca(2+), and Al(3+) release. Radiopacity and translucency were measured according to BS EN ISO 9917-1:2003. Results Ion release was linear to t(1/2) suggesting that this is a diffusion controlled mechanism rather than dissolution. The fluoride release from the cements is enhanced where some or all calcium is replaced by strontium. Radiopacity shows a strong linear correlation with Sr content. All cements were more opaque than the C0.70 0.55 standard but less opaque than the C0.70 0.90 standard which is the limit for the ISO requirement for acceptance. Significance This study shows that the replacement of calcium by strontium in a glass ionomer glass produces the expected increase in radiopacity of the cement without adverse effects on visual properties of the cement. The fluoride release from the cements is enhanced where some or all calcium is replaced by strontium.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Orthopaedic implants and arthroplasty

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (22)

Show source-provided references
1. Development of glass-ionomer cement systems10.1016/S0142-9612(97)00126-9 ↗
2. The evolution of glass ionomer cements10.1038/sj.bdj.4805723 ↗
3. The radiopacity of glass ionomer dental materials10.1111/j.1365-2842.1990.tb00005.x ↗
4. Lactic acid jet test: in vitro erosion rates of glass ionomer dental cements containing radiopacifying elements10.1016/0142-9612(93)90245-W ↗
5. Glass-cermet cements
6. Wilson AD, Kent BE. Surgical cement. British Patent 1,316,129
7. Billington RW, Williams JA. US Patent 4,861,808; issue date 1989.
8. Billington RW, Williams JA. US Patent 4,797,431; issue date 1989.
9. Fluoride release of glass ionomers
10. Kinetics of fluoride release from zinc oxide-based cements10.1016/S0142-9612(00)00441-5 ↗
11. Buffering and ion-release by a glass ionomer cement under near neutral and acidic conditions10.1016/S0142-9612(02)00014-5 ↗
12. Ion processes in glass ionomer cements10.1016/j.jdent.2005.09.008 ↗
13. Preliminary work on the antibacterial effect of strontium in glass ionomer cements10.1023/A:1025794927195 ↗
14. Fluoride release from model glass ionomer cements
15. Kinetics of fluoride release from glass components of glass ionomers10.1016/j.jdent.2009.02.007 ↗
16. Kinetics of fluoride release from dental glass ionomer restorative cements: the effects of ultrasound, radiant heat, and glass composition
17. Fluoride release from glass polyalkenoate (ionomer) cements
18. The effect of adding fluoride compounds to fluoride free glass ionomer cement on subsequent fluoride and sodium release
19. The lactic acid jet test: in vitro erosion rates of glass ionomer dental cements containing radiopacifying elements10.1016/0142-9612(93)90245-W ↗
20. ISO 9917-1-2007 Dentistry Water-based Cements.
21. A new technique for measuring the radiopacity of natural tooth substance and restorative materials10.1111/j.1365-2842.1987.tb00718.x ↗
22. The quantitative measurement of the opacity of aesthetic dental filling materials10.1177/00220345790580060801 ↗