Micro-XRD and temperature-modulated DSC investigation of nickel–titanium rotary endodontic instruments
Source abstract
Abstract
Objectives Employ Micro-X-ray diffraction and temperature-modulated differential scanning calorimetry to investigate microstructural phases, phase transformations, and effects of heat treatment for rotary nickel-titanium instruments. Methods Representative as-received and clinically used ProFile GT and ProTaper instruments were principally studied. Micro-XRD analyses (Cu Kalpha X-rays) were performed at 25 degrees C on areas of approximately 50 microm diameter near the tip and up to 9 mm from the tip. TMDSC analyses were performed from -80 to 100 degrees C and back to -80 degrees C on segments cut from instruments, using a linear heating and cooling rate of 2 degrees C/min, sinusoidal oscillation of 0.318 degrees C, and period of 60s. Instruments were also heat treated 15 min in a nitrogen atmosphere at 400, 500, 600 and 850 degrees C, and analyzed. Results At all Micro-XRD analysis regions the strongest peak occurred near 42 degrees , indicating that instruments were mostly austenite, with perhaps some R-phase and martensite. Tip and adjacent regions had smallest peak intensities, indicative of greater work hardening, and the intensity at other sites depended on the instrument. TMDSC heating and cooling curves had single peaks for transformations between martensite and austenite. Austenite-finish (A(f)) temperatures and enthalpy changes were similar for as-received and used instruments. Heat treatments at 400, 500 and 600 degrees C raised the A(f) temperature to 45-50 degrees C, and heat treatment at 850 degrees C caused drastic changes in transformation behavior. Significance Micro-XRD provides novel information about NiTi phases at different positions on instruments. TMDSC indicates that heat treatment might yield instruments with substantial martensite and improved clinical performance.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Endodontics and Root Canal Treatments · Orthodontics and Dentofacial Orthopedics · Dental materials and restorations
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (35)
Show source-provided references
1. An initial investigation of the bending and torsional properties of nitinol root canal files10.1016/S0099-2399(88)80196-1 ↗
2. An overview of nickel–titanium alloys used in dentistry10.1046/j.1365-2591.2000.00339.x ↗
3. The super-elastic property of the Japanese NiTi alloy wire for use in orthodontics10.1016/0889-5406(86)90021-1 ↗
4. Scanning electron microscope observations of new and used nickel–titanium rotary files10.1097/00004770-200310000-00014 ↗
5. SEM observations of nickel–titanium rotary endodontic instruments that fractured during clinical use10.1097/01.DON.0000132301.87637.4A ↗
6. Rotary NiTi instrument fracture and its consequences10.1016/j.joen.2006.06.008 ↗
7. Wear of nickel–titanium endodontic instruments evaluated by scanning electron microscopy: effect of ion implantation10.1097/00004770-200109000-00009 ↗
8. Fracture resistance of electropolished rotary nickel–titanium endodontic instruments10.1016/j.joen.2007.07.007 ↗
9. Does electropolishing improve the low-cycle fatigue behavior of a nickel–titanium rotary instrument in hypochlorite?10.1016/j.joen.2007.07.022 ↗
10. Effect of electropolishing ProFile nickel–titanium rotary instruments on cyclic fatigue resistance, torsional resistance, and cutting efficiency10.1016/j.joen.2007.10.007 ↗
11. K3 Endo, ProTaper, and ProFile systems: breakage and distortion in severely curved roots of molars10.1097/00004770-200404000-00013 ↗
12. Differential scanning calorimetric studies of nickel titanium rotary endodontic instruments10.1097/00004770-200208000-00001 ↗
13. Fatigue and mechanical properties of nickel–titanium endodontic instruments10.1097/00004770-200210000-00009 ↗
14. Differential scanning calorimetric studies of nickel–titanium rotary endodontic instruments after simulated clinical use10.1097/00004770-200211000-00007 ↗
15. Mechanical behavior at different temperatures and stresses for superelastic nickel–titanium orthodontic wires having different transformation temperatures10.1016/S0109-5641(01)00025-2 ↗
16. Micro X-ray diffraction study of superelastic nickel–titanium orthodontic wires at different temperatures and stresses10.1016/S0142-9612(01)00303-9 ↗
17. Modulated differential scanning calorimetry10.1007/BF02546852 ↗
18. A new approach to the calorimetric investigation of physical and chemical transitions10.1007/BF02546854 ↗
19. Temperature-modulated DSC study of phase transformations in nickel–titanium orthodontic wires10.1016/S0040-6031(02)00119-3 ↗
20. Temperature-modulated DSC provides new insight about nickel–titanium wire transformations10.1016/S0889-5406(03)00570-5 ↗
21. Orthodontic wires
22. A new calibration method for the X-ray powder diffraction study of shape memory alloys10.1002/pssa.2211480204 ↗
23. International Organization for Standardization. ISO Standard 15841. Dentistry–Wires for use in orthodontics; December 2006.
24. Microstructural studies of 35°C Copper Ni–Ti orthodontic wire and TEM confirmation of low-temperature martensite transformation10.1016/j.dental.2007.04.004 ↗
25. Cullity · 2001
26. Vickers hardness investigation of work-hardening in used NiTi rotary instruments10.1016/j.joen.2006.07.007 ↗
27. In-depth hardness profiles of stainless steel and Ni–Ti endodontic instrument cross-sections by nano-indentation10.1111/j.1365-2591.2008.01426.x ↗
28. Stress–strain–temperature relationship associated with the R-phase transformation in TiNi shape memory alloy (influence of shape memory processing temperature)
29. Microstructures of M-wire and superelastic NiTi wires for rotary instruments
30. The effect of surface treatments of nickel–titanium files on wear and cutting efficiency10.1016/S1079-2104(00)70103-X ↗
31. Depositions of nitrogen on NiTi instruments10.1097/00004770-200207000-00001 ↗
32. The effect of thermal treatment on the resistance of nickel–titanium rotary files in cyclic fatigue10.1016/j.tripleo.2006.12.026 ↗
33. Bending properties of superelastic and nonsuperelastic nickel–titanium orthodontic wires10.1016/0889-5406(91)70013-M ↗
34. X-ray diffraction study of low-temperature phase transformations in nickel–titanium orthodontic wires10.1016/j.dental.2008.03.005 ↗
35. Physical metallurgy of Ti–Ni-based shape memory alloys10.1016/j.pmatsci.2004.10.001 ↗