Comparative study on corrosion resistance and in vitro biocompatibility of bulk nanocrystalline and microcrystalline biomedical 304 stainless steel
Source abstract
Abstract
Objectives SUS 304 stainless steels have been widely used in orthodontics and implants such as archwires, brackets, and screws. The purpose of present study was to investigate the biocompatibility of both the commercial microcrystalline biomedical 304 stainless steel (microcrystalline 304ss) and novel-fabricated nanocrystalline 304 stainless steel (nanocrystalline 304ss). Methods Bulk nanocrystalline 304ss sheets had been successfully prepared by microcrystalline 304ss plates using severe rolling technique. The electrochemical corrosion and ion release behavior immersion in artificial saliva were measured to evaluate the property of biocorrosion in oral environment. The cell lines of murine and human cell lines from oral and endothelial environment were co-cultured with extracts to evaluate the cytotoxicity and provide referential evidence in vivo. Results The polarization resistance trials indicated that nanocrystalline 304ss is more corrosion resistant than the microcrystalline 304ss in oral-like environment with higher corrosion potential, and the amount of toxic ions released into solution after immersion is lower than that of the microcrystalline 304ss and the daily dietary intake level. The cytotoxicity results also elucidated that nanocrystalline 304ss is biologically compatible in vitro, even better than that of microcrystalline 304ss. Significance Based on the much higher mechanical and physical performances, nanocrystalline 304ss with enhanced biocorrosion property, well-behaved in vitro cytocompatibility can be a promising alternative in orthodontics and fixation fields in oral cavity.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Titanium Alloys Microstructure and Properties · Hydrogen embrittlement and corrosion behaviors in metals · Surface Treatment and Residual Stress
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (40)
Show source-provided references
1. Stainless steel in bone surgery10.1016/S0020-1383(00)80015-7 ↗
2. In-vitro evaluation of the material characteristics of stainless steel and beta-titanium orthodontic wires10.1016/j.ajodo.2004.12.030 ↗
3. No corrosion of 304 stainless steel implant after 40 years of service
4. The electrochemical behavior of metallic implant materials as an indicator of their biocompatibility10.1002/jbm.820210705 ↗
5. Electrochemical study of type 304 and 316L stainless steels in simulated body fluids and cell cultures10.1016/j.actbio.2006.06.003 ↗
6. Stress corrosion cracking of sensitized type 316 stainless steel in hydrochloric acid solution-effect of sensitizing time10.1016/S0010-938X(03)00002-7 ↗
7. Black · 1998
8. The role of metal corrosion in inflammatory processes: induction of adhesion molecules by heavy metal ions
9. The influence of surface condition on the localized corrosion of 316L stainless steel orthopedic implants
10. In vitro study of platelet adhesion on medical nickel-free stainless steel surface10.1016/j.matlet.2005.01.067 ↗
11. Webster · 2001 · 125
12. Ti based biomaterials, the ultimate choice for orthopaedic implants – a review
13. Nanocrystalline materials10.1016/0079-6425(89)90001-7 ↗
14. Crawford · Acta Biomaterialia · 2007 · 3 · 35910.1016/j.actbio.2006.08.004 ↗
15. Electrochemical corrosion behavior of nanocrystallized bulk 304 stainless steel10.1016/j.electacta.2006.06.023 ↗
16. Mechanical and electrochemical behavior of nanocrystalline surface of 304 stainless steel10.1016/S0013-4686(02)00365-1 ↗
17. The electrochemical corrosion of bulk nanocrystalline ingot Iron in acidic sulfate solution10.1021/jp0538971 ↗
18. The role of nanometer and sub-micron surface features on vascular and bone cell adhesion on titanium10.1016/j.biomaterials.2007.11.009 ↗
19. Corrosion behavior of nancrystallized bulk 304 stainless steel I: the research on anti-chloride ion attack of the passive film
20. Long K, Wang SG. A fabrication method of bulk nanocrystalline metallic materials. Patent no. ZL01128256.8.
21. Preparation and electrochemical corrosion behavior of bulk nanocrystalline ingot iron in HCl acid solution10.1021/jp046297v ↗
22. Ion release from NiTi orthodontic wires in artificial saliva with various acidities10.1016/S0142-9612(03)00188-1 ↗
23. ASTM-G31-72 · 2004
24. ANSI/AAMI/ISO 10993-5 · 1999
25. Jenkins · 1996
26. Davis · 2001
27. Metallic materials
28. Orthodontic wires
29. Mechanical properties and clinical applications of orthodontic wires10.1016/0889-5406(89)90251-5 ↗
30. Mechanical properties of orthodontic wires in tension, bending and torsion10.1016/0002-9416(82)90140-3 ↗
31. In-vitro evaluation of the material characteristics of stainless steel and beta-titanium orthodontic wires10.1016/j.ajodo.2004.12.030 ↗
32. Standard terminology relating to corrosion and corrosion testing G15-07. In annual book of ASTM standard, vol. 03, corrosion of metals; wear and erosion; 2007.
33. Hip implants-paper VI-ion concentrations10.1016/j.matdes.2005.05.018 ↗
34. Trace element risk assessment: essentiality vs. toxicity10.1016/S0273-2300(02)00020-X ↗
35. Food labeling: reference daily intakes
36. Elemental ion release from four different fixed prosthodontic materials10.1016/j.dental.2009.02.004 ↗
37. Ion release and cytotoxicity of stainless steel wires10.1093/ejo/cji047 ↗
38. Cytotoxicity evaluation of 43 metal salts using murine fibroblasts and osteoblastic cells10.1002/(SICI)1097-4636(199802)39:2<331::AID-JBM22>3.0.CO;2-E ↗
39. Commission Directive2004/96/EC · Official Journal of the European Union · 2004 · L301 · 51
40. Effect of calcium-ion implantation on the corrosion resistance and biocompatibility of titanium10.1016/S0142-9612(00)00405-1 ↗