Effect of exposure time and pre-heating on the conversion degree of conventional, bulk-fill, fiber reinforced and polyacid-modified resin composites
Source abstract
Abstract
Objective To determine the degree of conversion (DC) of different type of resin-based composites (RBC) in eight-millimeter-deep clinically relevant molds, and investigate the influence of exposure time and pre-heating on DC. Methods Two-millimeter-thick samples of conventional sculptable [FiltekZ250 (FZ)], flowable [Filtek Ultimate Flow (FUF)] and polyacid-modified [Twinky Star Flow (TS)] RBCs, and four-millimeter-thick samples of flowable bulk-fill [Filtek Bulk Fill Flow (FBF), Surefil SDR (SDR)] and sculptable fibre-reinforced [EverX Posterior (EX)] RBCs were prepared in an eight-millimeter-deep mold. The RBCs temperature was pre-set to 25, 35 and 55°C. The RBCs were photopolymerized with the recommended and its double exposure time. The DC at the top and bottom was measured with micro-Raman spectroscopy. Data were analyzed with ANOVA and Scheffe post-hoc test (p<0.05). Results The differences in DC% between the top/bottom and the recommended/extended exposure time were significant for the materials, except SDR (64.5/63.0% and 67.4/63.0%). FUF (69.0% and 53.4%) and TS (64.9% and 60.9%) in 2mm provided higher DC% at the top and bottom with the recommended curing time, compared to the other materials, except SDR. Pre-heating had negative effect on DC at the bottom in flowable RBCs (FUF: 48.9%, FBF: 36.7%, SDR: 43%, TS: 54.7%). Pre-heating to 55 °C significantly increased the DC% in fibre-reinforced RBC (75.0% at the top, 64.7% at the bottom). Significance Increased exposure time improves the DC for each material. Among bulk-fills, only SDR performed similarly, compared to the two-millimeter-thick flowable RBCs. Pre-heating of low-viscosity RBCs decreased the DC% at the bottom. Pre-heating of fibre-reinforced RBC to 55°C increased the DC% at a higher rate than the extended curing time.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Anatomy and Medical Technology · Orthodontics and Dentofacial Orthopedics
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (53)
Show source-provided references
1. Longevity of posterior composite restorations: not only a matter of materials10.1016/j.dental.2011.09.003 ↗
2. Importance of coronal seal: preventing coronal leakage in endodontics10.4103/2321-4619.188224 ↗
3. Recent advances and developments in composite dental restorative materials10.1177/0022034510381263 ↗
4. Curing behavior of high-viscosity bulk-fill composites10.1016/j.jdent.2014.05.012 ↗
5. Long-term sorption and solubility of bulk-fill and conventional resin-composites in water and artificial saliva10.1016/j.jdent.2015.10.001 ↗
6. Degree of conversion of bulk-fill compared to conventional resin-composites at two time intervals10.1016/j.dental.2013.05.011 ↗
7. Bulk-filling of high C-factor posterior cavities: effect on adhesion to cavity-bottom dentin10.1016/j.dental.2012.11.002 ↗
8. Marginal quality of flowable 4-mm base vs. conventionally layered resin composite10.1016/j.jdent.2011.07.004 ↗
9. Bulk-fill resin-based composites: an in vitro assessment of their mechanical performance10.2341/12-395-L ↗
10. Polymerization shrinkage and depth of cure of bulk-fill resin composites and highly filled flowable resin10.2341/13-307-L ↗
11. Degree of conversion and BisGMA, TEGDMA, UDMA elution from flowable bulk fill composites10.3390/ijms17050732 ↗
12. An overview of development and status of fiber-reinforced composites as dental and medical biomaterials10.1080/23337931.2018.1457445 ↗
13. Physical properties and depth of cure of a new short fiber reinforced composite10.1016/j.dental.2013.04.016 ↗
14. In vitro fracture resistance of molar teeth restored with a short fibre-reinforced composite material10.1016/j.jdent.2014.05.004 ↗
15. In vitro evaluation of microleakage of class II packable composite resin restorations using flowable composite and resin modified glass ionomers as intermediate layers10.4103/0972-0707.87215 ↗
16. Flowable resin composites: a systematic review and clinical considerations
17. Composite pre-heating: effects on marginal adaptation, degree of conversion and mechanical properties10.1016/j.dental.2010.03.023 ↗
18. The effect of resin composite pre-heating on monomer conversion and polymerization shrinkage10.1016/j.dental.2008.10.006 ↗
19. Effects of different temperatures and storage time on the degree of conversion and microhardness of resin-based composites10.5005/jp-journals-10024-1830 ↗
20. Monomer conversion of pre-heated composite10.1177/154405910508400716 ↗
21. Polymerization kinetics of pre-heated composite10.1177/154405910608500106 ↗
22. Pre-heating of high-viscosity bulk-fill resin composites: effects on shrinkage force and monomer conversion10.1016/j.jdent.2015.07.014 ↗
23. Resin composite-state of the art10.1016/j.dental.2010.10.020 ↗
24. Factors affecting polymerization of resin-based composites: a literature review10.1016/j.sdentj.2017.01.002 ↗
25. Effect of light intensity and exposure duration on cure of resin composite
26. How light irradiance and curing time affect monomer conversion in light-cured resin composites10.1111/j.0909-8836.2003.00082.x ↗
27. Energy dependent polymerization of resin-based composite10.1016/S0109-5641(01)00069-0 ↗
28. The reciprocity low concerning light dose relationships applied to BisGMA/TEGDMA photopolymers: theoretical analysis and experimental characterization10.1016/j.dental.2014.02.021 ↗
29. Examining exposure reciprocity in a resin based composite using high irradiance levels and real-time degree of conversion values10.1016/j.dental.2015.02.010 ↗
30. Curing characteristics of a composite. Part 2: the effect of curing configuration on depth and distribution of cure10.1016/j.dental.2014.02.013 ↗
31. Progress in dimethacrylate-based dental composite technology and curing efficiency10.1016/j.dental.2012.11.005 ↗
32. Light-curing units: a review of what we need to know10.1177/0022034515594786 ↗
33. The effect of filler and silane content on conversion of resin-based composite10.1016/S0109-5641(02)00062-3 ↗
34. Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites10.1007/s00784-013-1177-y ↗
35. Investigations on a methacrylate-based flowable composite based on the SDR™ technology10.1016/j.dental.2010.11.014 ↗
36. Shrinkage behaviour of flowable resin-composites related to conversion and filler-fraction10.1016/j.jdent.2007.05.001 ↗
37. Polymerization kinetics and impact of post polymerization on the degree of conversion of bulk-fill resin-composite at clinically relevant depth10.1016/j.dental.2015.07.004 ↗
38. Effect of the amount of 3-methacyloxypropyltrimethoxysilane coupling agent on physical properties of dental resin nanocomposites10.1016/j.dental.2009.03.016 ↗
39. Bulk-fill resin composites: polymerization properties and extended light curing10.1016/j.dental.2014.12.010 ↗
40. Resin composite properties and energy density of light cure10.1177/154405910508400715 ↗
41. Effect of high-intensity curing lights on the polymerization of bulk-fill composites10.1016/j.dental.2018.06.005 ↗
42. Polymerization efficiency and flexural strength of low-stress restorative composites10.1016/j.dental.2014.03.006 ↗
43. Polymerization shrinkage and depth of cure of bulk fill flowable composite resins10.2341/12-484-L ↗
44. Impact of light transmittance mode on polymerisation kinetics in bulk-fill resin-based composites10.1016/j.jdent.2017.05.017 ↗
45. Curing characteristics of flowable and sculptable bulk-fill composites10.1007/s00784-016-1894-0 ↗
46. Synthesis, characterization and evaluation of urethane derivatives of Bis-GMA10.1016/S0109-5641(02)00108-2 ↗
47. Clinically relevant issues related to preheating composites10.1111/j.1708-8240.2006.00046.x ↗
48. Intraoral humidity during operative procedures10.1016/0300-5712(94)90007-8 ↗
49. Effects of curing time and filler concentration on curing and postcuring of urethane dimethacrylate composites: a microcalorimetric study10.1002/(SICI)1097-4636(199805)40:2<224::AID-JBM7>3.0.CO;2-N ↗
50. Plueddemann · 1982
51. Evaluation of degree of conversion and hardness of dental composites photoactivated with different light guide tips
52. The effect of soft-start polymerization by second generation LEDs on the degree of conversion of resin composite10.2341/06-45 ↗
53. Analysis of optical transmission by 400-500 nm visible light into aesthetic dental biomaterials10.1016/0300-5712(94)90014-0 ↗