Uniaxial/biaxial flexure strengths and elastic properties of resin-composite block materials for CAD/CAM
Source abstract
Abstract
Objective Comparing strengths under different loading conditions provides useful information on the mechanical behaviour of restorative materials under multiaxial masticatory loading in the oral cavity. The aims of this study was to investigate the flexural strengths and the reliability of resin-composite blocks for CAD/CAM by uniaxial and biaxial flexure tests and to compare the elastic properties measured by different methods including digital image correlation (DIC). Methods Four resin-composite blocks for CAD/CAM, namely, VE (Vita Enamic), LU (Lava Ultimate), MD (Mazic Duro), and CS (Cerasmart), were investigated. Beam specimens (4.0×1.4×18.0mm3) and disks (12-14mmϕ×1.5mm) were prepared to determine the uniaxial (three-point bending) and biaxial (ball-on-ring, BOR) flexural strengths and flexural moduli. A compression test (8×4×18mm3) with DIC analysis was utilized to measure the elastic modulus and Poisson's ratio. Data were analysed by a 2-parameter Weibull function and ANOVA with Scheffe's test. Results The mean uniaxial and biaxial strengths and Weibull moduli of the specimen groups were as follows: uniaxial VE (140.1±7.0, 24.1), LU (159.1±6.3, 31.5), MD (144.9±13.3, 13.6), and CS (165.4±16.9, 11.2) and biaxial VE (153.6±10.4, 19.0), LU (231.0±29.3, 9.7), MD (148.9±23.8, 7.4), and CS (249.7±22.4, 13.8). Although the ranking of both sets of strength data remained unchanged, the strength reliability was significantly affected by the loading; the Weibull moduli of the specimens decreased when they were subjected to biaxial tests (except for that of CS). The elastic modulus values of the materials varied significantly under the different test loadings, although they were in the same order regardless of the test method: VE>>LU≈MD>CS. The DIC technique yielded elastic moduli that were in good agreement with those measured by the uniaxial flexure test. Significance The flexural strength, reliability, and elastic modulus of resin-composite block materials differed with the uniaxial and biaxial flexural loading and the test method. The different behaviours under both loadings should be considered in the evaluation of the mechanical performance of those materials.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Dental Health and Care Utilization · Dental Implant Techniques and Outcomes
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (69)
Show source-provided references
1. From atisanal to CAD-CAM blocks: state of the art of indirect composites10.1177/0022034516634286 ↗
2. Resin-composite blocks for dental CAD/CAM applications10.1177/0022034514553976 ↗
3. Dental biomaterials for chairside CAD/CAM: state of the art10.4047/jap.2017.9.6.486 ↗
4. Chairside CAD/CAM materials. Part 1: measurement of elastic constants and microstructural characterization10.1016/j.dental.2016.10.009 ↗
5. A novel polymer infiltrated ceramic dental material10.1016/j.dental.2011.02.002 ↗
6. In-vitro strength degradation of dental ceramics and novel PICN material by sharp indentation10.1016/j.jmbbm.2013.05.004 ↗
7. Investigation of the correlation between the different mechanical properties of resin composites10.4012/dmj.2012-178 ↗
8. Clinical performance of chairside CAD/CAM restorations10.14219/jada.archive.2006.0395 ↗
9. Academy of dental materials guidance—resin composites: Part I—mechanical properties10.1016/j.dental.2017.04.013 ↗
10. Chairside CAD/CAM materials. Part 2: flexural strength testing10.1016/j.dental.2016.10.008 ↗
11. Mechanical properties of resin-ceramic CAD/CAM restorative materials10.1016/j.prosdent.2015.04.016 ↗
12. Mechanical properties of composite resin blocks for CAD/CAM10.4012/dmj.2014-208 ↗
13. The effect of surface treatments on the mechanical and optical behaviors of CAD/CAM restorative materials
14. Wear, strength, modulus and hardness of CAD/CAM restorative materials10.1016/j.dental.2016.08.222 ↗
15. Degradation fatigue, and failure of resin dental composite materials10.1177/154405910808700802 ↗
16. Influence of test method on failure stress of brittle dental materials10.1177/00220345900690120201 ↗
17. The reliability in flexural strength testing of a novel dental composite10.1016/S0300-5712(03)00110-6 ↗
18. Flexural strength of dental composite restoratives: comparison of biaxial and three-point bending test10.1002/jbm.b.30103 ↗
19. The ball on three balls test for strength testing of brittle discs: stress distribution in the disc10.1016/S0955-2219(01)00458-7 ↗
20. Ball-on-ring test revisited10.1111/j.1151-2916.1989.tb07702.x ↗
21. Biaxial flexure tests for ceramics
22. Fatigue of dental ceramics in a simulated oral environment10.1177/00220345860650071901 ↗
23. Flexure tests on dental ceramics
24. Evaluating acrylic and glass-ionomer cement strength using the biaxial flexure test10.1016/S0142-9612(00)00324-0 ↗
25. Biaxial flexural strength testing of ceramic materials
26. Effect of test method on flexural strength of recent dental ceramics10.4012/dmj.23.490 ↗
27. Effect of elastic modulus mismatch on failure behaviour of glass ionomer cement under Hertzian indentation10.1016/j.dental.2011.11.004 ↗
28. The influence of elastic modulus mismatch between tooth and post and core restorations on root fracture10.1111/j.1365-2591.2012.02092.x ↗
29. Equivalent Young’s modulus of composite resin for simulation of stress during dental restoration10.1016/j.dental.2016.10.007 ↗
30. Elastic modulus of resin-based dental restorative materials: a microindentation approach10.1002/jbm.b.30145 ↗
31. Correlation of filler content and elastic properties of resin-composites10.1016/j.dental.2007.11.007 ↗
32. Dynamic and static moduli of elasticity of resin-based materials10.1016/S0109-5641(01)00021-5 ↗
33. Measurement at low strain rates of the elastic properties of dental polymeric materials10.1016/S0109-5641(99)00011-1 ↗
34. Biaxial flexural modulus of antibiotic-impregnated orthopedic bone cement10.1002/jbm.b.30771 ↗
35. A simple method of determining the modulus of orthopedic bone cement10.1002/1097-4636(2001)58:2<188::AID-JBM1006>3.0.CO;2-V ↗
36. The impact of composite structure on its elastic response10.1177/00220345860650050301 ↗
37. Mechanical properties and filler fraction of dental composites10.1016/0109-5641(89)90128-0 ↗
38. Digital image correlation10.1016/S1369-7021(10)70235-2 ↗
39. Measuring microscopic deformations with digital image correlation10.1016/S0143-8166(96)00041-3 ↗
40. Assessment of speckle-pattern quality in digital image correlation based on gray intensity and speckle morphology10.1016/j.optlaseng.2016.11.001 ↗
41. A new method combining finite element analysis and digital image correlation to assess macroscopic mechanical properties of dentin10.3390/ma8020535 ↗
42. A new imaging technique for measuring the surface strains applied to dentine10.1016/S0300-5712(99)00054-8 ↗
43. Applications of digital image correlation to biological tissues10.1117/1.1753270 ↗
44. A study of polymerization shrinkage kinetics using digital image correlation10.1016/j.dental.2015.01.001 ↗
45. Measurement of the full-field polymerization shrinkage and depth of cure of dental composites using digital image correlation10.1016/j.dental.2008.11.001 ↗
46. Evaluation of the flexural mechanical properties of various thermoplastic denture base polymers10.4012/dmj.2017-373 ↗
47. Piston-on-three-ball versus piston-on-ring in evaluating the biaxial strength of dental ceramics10.1016/j.dental.2011.02.011 ↗
48. Symmetrical bending of thin circular elastic plates on equally spaced point supports
49. Verification of ball-on-ring test using finite element analysis
50. Stresses in concrete pavements computed by theoretical analysis
51. A practical and systematic review of Weibull statistics for reporting strengths of dental materials10.1016/j.dental.2009.09.006 ↗
52. Full-field speckle pattern image correlation with B-Spline deformation function10.1007/BF02410992 ↗
53. The span length and cross-sectional design affect values of strength10.1016/j.dental.2004.05.009 ↗
54. Fundamentals of matrials scienc
55. Reliability, failure probability, and strength of resin-based materials for CAD/CAM restorations10.1590/1678-775720150561 ↗
56. Fractography of biaxial tested Si3N4-specimens10.1016/j.jeurceramsoc.2013.12.038 ↗
57. ASTM F394-78 (Reappproved 1996) · 1996
58. Large-deflection solution of the coaxial-ring-circular-glass-plate flexure problem10.1111/j.1151-2916.1971.tb12209.x ↗
59. The mechanical properties and bioactivity of poly(methyl methacrylate)/SiO(2)-CaO nanocomposite10.1016/j.biomaterials.2009.03.002 ↗
60. Correlations among bending test methods for dental hard resins10.4012/dmj.2016-304 ↗
61. A critical view on biaxial and short-beam uniaxial flexural strength tests applied to resin composites using Weibull, fractographic and finite element analyses10.1016/j.dental.2009.09.002 ↗
62. Reliability analysis of structural ceramics subjected to biaxial flexure10.1111/j.1151-2916.1991.tb06884.x ↗
63. A biaxial-flexure test for evaluating ceramic strengths10.1111/j.1151-2916.1983.tb09964.x ↗
64. Weibull statistics effective area and volume in the ball-on-ring testing method10.1016/j.mechmat.2013.10.010 ↗
65. The ball on three balls test: strength testing of specimens of different sizes and geometries
66. Fracture strength of α- and β-SiAION measured by biaxial and four-point bending10.1111/j.1151-2916.1990.tb05285.x ↗
67. Accurate characterization of machine compliance for simple compression testing
68. Determination of Young’s modulus of metallic and composite materials by digital image correlation
69. Mechanical properties of magnesia–spinel composites10.1111/j.1551-2916.2007.01733.x ↗