journal article·2006-12

Light exposure required for optimum conversion of light activated resin systems

Rie Nomoto, Masayuki Asada, John F. McCabe, Susumu Hirano

Dental Materials· Volume 22· Issue 12
Publisher page

Abstract

Objective The aim of this study was to evaluate the relationship between the degree of conversion (DC) of composites and the light intensity using LED-curing units and also to determine the amount of exposure required to achieve optimal curing. Method The light outputs of light-curing units and the depths of cure of composites exposed to these units were determined using the methods outlined in modified ISO standards, ISO/TS10650 and ISO 4049, respectively. The distributions of DC in composites were investigated by IR spectra of microareas obtained at various depths from the irradiated surface of thin specimens cut out from the cured composites. IR spectra were measured using a Fourier transform infrared spectrometer equipped with a microscopic unit. DC was calculated from the changes in the amount of C=C double bonds in the IR spectra. Results The light intensity at various depths through the cured composite was calculated from the attenuation coefficient of each material, obtained from the linear relationship between the depth of cure and the logarithm of the amount of exposure, which is defined as the product of the irradiance and irradiation time. There was a third or fourth order regression relationship between DC and the logarithm of total light energy at a particular depth. Significance The minimum light energy required to produce a saturated DC was about 1000 s mW/cm2.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Photopolymerization techniques and applications · Dental materials and restorations · Epoxy Resin Curing Processes

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (23)

Show source-provided references
1. Factors affecting the depth of cure of UV-polymerized composites
2. Conversion in different depths of ultraviolet and visible light activated composite materials10.3109/00016358209012726 ↗
3. Invitro depth of cure of photoactivated composites10.1177/00220345820610101601 ↗
4. Curing efficiency and ocular hazards of dental photopolymerization sources10.1016/0142-9612(86)90033-5 ↗
5. Degree of double bond conversion in light-cured composites10.1016/S0109-5641(87)80055-6 ↗
6. Output from visible-light activation units and depth of cure of light-activated composites10.1177/00220345890680111301 ↗
7. The distribution of degree of conversion in light-curd composite resins
8. Effect of light intensity on polymerization of light-cured composite resins10.4012/dmj.13.198 ↗
9. Residual monomer and pendant methacryoloyl group in light-cured composite resins10.4012/dmj.11.177 ↗
10. The effect of a light-cured periodontal dressing material on HeLa cells and fibroblasts in vitro10.1902/jop.1994.65.4.324 ↗
11. Cytotoxic effects of acrylates and methacrylates: relationships of monomer structures and cytotoxicity10.1002/(SICI)1097-4636(19971215)37:4<517::AID-JBM10>3.0.CO;2-5 ↗
12. Resin composite monomers alter MTT and LDH activity of human gingival fibroblasts in vitro10.1016/S0109-5641(03)00053-8 ↗
13. An infrared spectroscopic study of sealants
14. Remaining methacrylate groups in composite restorative materials10.3109/00016358209024081 ↗
15. Restorative resins: hardness and strength vs. quantity of remaining double bonds
16. Compressive creep of light cured resin based restorative materials10.3109/00016358209024076 ↗
17. Correlation between hardness and degree of conversion during the setting reaction of unfilled dental restorative resins10.1016/S0109-5641(85)80058-0 ↗
18. The effect of resin formulation on the degree of conversion and mechanical properties of dental restorative resins10.1002/jbm.820200111 ↗
19. Correlation of parameters used to estimate monomer conversion in a light-cured composite10.1177/00220345880670060801 ↗
20. Ultraviolet light-induced yellowing of dental restorative resins10.1016/0022-3913(85)90418-4 ↗
21. International Organization for Standardization. ISO TS 10650 dental equipment—powered polymerization activators, Geneva, Switzerland, 1999.
22. International Organization for Standardization. ISO 4049 dentistry—polymer-based filling, restorative and luting materials, Geneva, Switzerland, 1998.
23. Effect of aperture size on irradiance of LED curing units10.1016/j.dental.2004.01.002 ↗