Effects of different sterilization methods on surface characteristics and biofilm formation on zirconia in vitro
Source abstract
Abstract
Objective The current laboratory study was to investigate the effect of different sterilization treatments on surface characteristics of zirconia, and biofilm formation on zirconia surface after exposure to these sterilization treatments. Methods Commercially available zirconia discs (Cerconbase, Degu-Dent, Hanau, Germany) were prepared and polished to the same value of surface roughness. The discs were treated with one of the following sterilization methods steam autoclave sterilization, dry heat sterilization, ultraviolet C (UVC) irradiation, and gamma (γ) ray irradiation. The characteristics of zirconia surfaces were evaluated by scanning electron microscopy (SEM), surface roughness, surface free energy (SFE), X-ray photoelectron spectroscopy (XPS), and X-ray diffraction (XRD) measurements. Then, Staphylococcus aureus (S.a.) and Porphyromonas gingivalis (P.g.) bacteria were used and cultured on the respective sterilized zirconia surfaces. The amount of biofilm formation on zirconia surface was quantified by colony forming unit (CFU) counts. Results Significant modifications were detected on the colour and SFE of zirconia. The colour of zirconia samples after UVC irradiation became light yellow whilst dark brown colour was observed after gamma ray irradiation. Moreover, UVC and gamma ray irradiation increased the hydrophilicity of zirconia surface. Overall, dry heat sterilized samples showed the significantly lowest amount of bacteria growth on zirconia, while UVC and gamma ray irradiation resulted in the highest. Significance It is evident that various sterilization methods could change the surface which contribute to different biofilm formation and colour on zirconia.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Oral microbiology and periodontitis research · Dental materials and restorations · Nanoparticles: synthesis and applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (61)
Show source-provided references
1. Zirconia dental implants: a literature review10.1563/AAID-JOI-D-09-00079 ↗
2. Stabilized zirconia as a structural ceramic: an overview10.1016/j.dental.2007.05.005 ↗
3. A retrospective clinical study with regard to survival and success rates of zirconia implants up to and after 7 years of loading10.1111/cid.12323 ↗
4. A systematic review of the clinical survival of zirconia implants10.1007/s00784-016-1853-9 ↗
5. Comparison of clinical performance of zirconia implants and titanium implants in animal models: a systematic review10.11607/jomi.2817 ↗
6. Are ceramic implants a viable alternative to titanium implants? A systematic literature review10.1111/j.1600-0501.2009.01785.x ↗
7. Zirconia established facts and perspectives for a biomaterial in dental implantology10.1002/jbm.b.31147 ↗
8. A review on biomaterials in dental implantology10.59566/IJBS.2015.11113 ↗
9. From porcelain-fused-to-metal to zirconia: clinical and experimental considerations10.1016/j.dental.2010.10.024 ↗
10. Zirconia in dental implantology: a review10.4103/2231-0762.158014 ↗
11. Improved osseointegration of long-term stored SLA implant by hydrothermal sterilization10.1016/j.jmbbm.2015.08.038 ↗
12. Effects of sterilization treatments on bulk and surface properties of nanocomposite biomaterials10.1002/jbm.b.32928 ↗
13. Influence of sterilization method on the bond strength of caries-affected dentin10.1590/S1806-83242009000100003 ↗
14. Effects of different sterilization techniques and varying anodized TiO2 nanotube dimensions on bacteria growth10.1002/jbm.b.32870 ↗
15. Influence of sterilization on the mineralization of titanium implants induced by incubation in various biological model fluids10.1016/S0142-9612(03)00372-7 ↗
16. Influence of sterilization method on the bond strength of caries-affected dentin10.1590/S1806-83242009000100003 ↗
17. An overview of nickel–titanium alloys used in dentistry10.1046/j.1365-2591.2000.00339.x ↗
18. Effect of steam versus dry-heat sterilization on the wear of orthodontic ligature-cutting pliers10.1067/mod.2002.122175 ↗
19. Sakurai M, Shigeno A, Noguchi Y. UV-sterilizer for a dental implement such as a reamer and drill, Google Patents, 1988.
20. Enhanced osteoblast function on ultraviolet light-treated zirconia10.1016/j.biomaterials.2008.11.024 ↗
21. Tissue response to commercial silicone and polyurethane elastomers after different sterilization procedures10.1016/0142-9612(96)00055-5 ↗
22. Effect of steam versus dry-heat sterilization on the wear of orthodontic ligature-cutting pliers10.1067/mod.2002.122175 ↗
23. Gamma-ray sterilization effects in silica nanoparticles/gamma-APTES nanocomposite-based pH-sensitive polysilicon wire sensors10.3390/s110908769 ↗
24. Ultraviolet radiation in wound care: sterilization and stimulation10.1089/wound.2012.0366 ↗
25. Surface modification of zirconia with polydopamine to enhance fibroblast response and decrease bacterial activity in vitro: a potential technique for soft tissue engineering applications10.1016/j.colsurfb.2015.06.047 ↗
26. Bacterial adhesion mechanisms on dental implant surfaces and the influencing factors10.1016/j.ijadhadh.2016.03.022 ↗
27. Effects of multiple sterilization on surface characteristics and in vitro biologic responses to titanium10.1016/S0278-2391(96)90694-1 ↗
28. Glucose stabilizes collagen sterilized with gamma irradiation10.1002/jbm.a.20018 ↗
29. The effect of gamma-sterilization on the pH-ChemFET behaviour10.1016/j.sna.2008.05.022 ↗
30. Effect of dry heat and steam sterilization on load-deflection characteristics of β-titanium wires: an in vitro study10.4103/1735-3327.104871 ↗
31. The role of sterilization in the cytocompatibility of titania nanotubes10.1016/j.biomaterials.2009.11.103 ↗
32. Evaluation of four surface coating treatments for resin to zirconia bonding10.1016/j.jmbbm.2013.12.011 ↗
33. Estimation of the surface free energy of polymers10.1002/app.1969.070130815 ↗
34. Surface properties of titanium and zirconia dental implant materials and their effect on bacterial adhesion10.1016/j.jdent.2011.12.006 ↗
35. Surface characterization of zirconia dental implants10.1016/j.dental.2009.11.079 ↗
36. A new modified laser pretreatment for porcelain zirconia bonding10.1016/j.dental.2013.03.002 ↗
37. Comparison of quantification methods illustrates reduced Pseudomonas aeruginosa activity on nanorough polyvinyl chloride10.1002/jbm.b.31821 ↗
38. Formation of color centers in glasses exposed to gamma radiation10.1111/j.1151-2916.1955.tb14568.x ↗
39. Color stability of sealed composite resin restorative materials after ultraviolet artificial aging and immersion in staining solutions10.1016/S0022-3913(11)60038-3 ↗
40. Effect of cleaning and sterilization on titanium implant surface properties and cellular response10.1016/j.actbio.2011.11.026 ↗
41. Comparative evaluation of topographical data of dental implant surfaces applying optical interferometry and scanning electron microscopy10.1016/j.dental.2017.04.020 ↗
42. Characterization of novel silane coatings on titanium implant surfaces10.1111/j.1600-0501.2012.02504.x ↗
43. Nanoscale topographic changes on sterilized glass surfaces affect cell adhesion and spreading10.1002/jbm.a.34943 ↗
44. Change in surface properties of zirconia and initial attachment of osteoblastlike cells with hydrophilic treatment10.4012/dmj.2012-069 ↗
45. Influence of surface topography and surface physicochemistry on wettability of zirconia (tetragonal zirconia polycrystal)10.1002/jbm.b.32846 ↗
46. Gamma ray treatment enhances bioactivity and osseointegration capability of titanium10.1002/jbm.b.32799 ↗
47. Optimal sterilization method for the zirconia/alumina composites used for total hip replacements10.1002/jbm.b.31358 ↗
48. Phase transformation, roughness, and microhardness of artificially aged yttria- and magnesia-stabilized zirconia femoral heads10.1002/jbm.a.31438 ↗
49. Concerns of hydrothermal degradation in CAD/CAM zirconia10.1177/0022034509354193 ↗
50. Fatigue and damage tolerance of Y-TZP ceramics in layered biomechanical systems
51. Effect of material characteristics and/or surface topography on biofilm development10.1111/j.1600-0501.2006.01353.x ↗
52. The effect of titanium implant surface modification on the dynamic process of initial microbial adhesion and biofilm formation10.1016/j.ijadhadh.2016.03.018 ↗
53. A review on the wettability of dental implant surfaces II: biological and clinical aspects10.1016/j.actbio.2014.03.032 ↗
54. Oral bacterial adhesion on amorphous carbon and titanium films: effect of surface roughness and culture media10.1002/jbm.b.31506 ↗
55. Periodontal and peri-implant microbiota in patients with healthy and inflamed periodontal and peri-implant tissues10.1111/clr.12508 ↗
56. Photodynamic Antimicrobial Chemotherapy (PACT) in osteomyelitis induced by Staphylococcus aureus: microbiological and histological study10.1016/j.jphotobiol.2015.06.005 ↗
57. A review of dental implants and infection10.1016/j.jhin.2009.02.010 ↗
58. Effects of oral implant surface roughness on bacterial biofilm formation and treatment efficacy10.11607/jomi.3099 ↗
59. Effect of sterilization and water rinsing on cell adhesion to titanium surfaces10.1016/j.apsusc.2014.05.096 ↗
60. Effect of nanotubular-micro-roughened titanium surface on cell response in vitro and osseointegration in vivo10.1016/j.msec.2009.08.004 ↗
61. Plasma protein adsorption pattern on characterized ceramic biomaterials10.1016/S0142-9612(01)00244-7 ↗