Sliding contact wear and subsurface damage of CAD/CAM materials against zirconia
Source abstract
Abstract
Objective Most previous work conducted on the wear behavior of dental materials has focused on wear rates and surface damage. There is, however, scarce information regarding the subsurface damage arising from sliding contact fatigue. The aim of this study was to elucidate the wear mechanisms and the subsurface damage generated during sliding contact fatigue in 5 contemporary CAD/CAM materials against a zirconia indenter. Methods Forty discs (Ø12mm, 1.55mm thick) were cut out of IPS e.max CAD (e.CAD), Suprinity PC (SUP), Enamic (ENA), Vitablocs Mark II (VMII) and Lava Ultimate (LU) blocks and mirror polished. After cementation onto a dentin-like composite, off-axis mouth-motion cycling was conducted with a spherical zirconia indenter (r=3.18mm) in water (200N load, 2Hz frequency) for 5 different cycling periods (102, 103, 104, 105, 106 cycles, n=8). Analysis of the wear scars was conducted using light-microscopy, scanning-electron-microscopy and optical profilometry. Subsurface damage was assessed using sagittal and transverse sections of the samples. Results Fatigue wear mechanisms predominated in glassy materials (e.CAD, SUP, VMII), accompanied by extensive subsurface damage, whereas abrasive wear mechanisms were responsible for the large wear craters in the resin composite (LU) with an absolute absence of subsurface fracture. A combination of both mechanisms was observed in the polymer-infiltrated reinforced-glass (ENA), displaying large wear craters and severe subsurface damage. Significance Well-controlled laboratory simulation can identify wear and subsurface damage susceptibility of various classes of restorative materials. Both wear and subsurface fracture are determining factors for the long-term success of restorations.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Dental Erosion and Treatment
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (52)
Show source-provided references
1. Chairside CAD/CAM materials. Part 1: measurement of elastic constants and microstructural characterization10.1016/j.dental.2016.10.009 ↗
2. Can CAD/CAM resin blocks be considered as substitute for conventional resins?10.1016/j.dental.2017.09.003 ↗
3. Chairside CAD/CAM materials. Part 2: flexural strength testing10.1016/j.dental.2016.10.008 ↗
4. Mechanical properties of zirconia reinforced lithium silicate glass-ceramic10.1016/j.dental.2016.03.013 ↗
5. Static and fatigue mechanical behavior of three dental CAD/CAM ceramics10.1016/j.jmbbm.2016.01.023 ↗
6. Evaluation of mechanical and optical behavior of current esthetic dental restorative CAD/CAM composites10.1016/j.jmbbm.2015.10.004 ↗
7. Microstructure characterization and scg of newly engineered dental ceramics10.1016/j.dental.2016.03.018 ↗
8. Fracture toughness testing of biomedical ceramic-based materials using beams, plates and discs10.1016/j.jeurceramsoc.2018.08.012 ↗
9. Wear, strength, modulus and hardness of CAD/CAM restorative materials10.1016/j.dental.2016.08.222 ↗
10. Wear characteristics of current aesthetic dental restorative CAD/CAM materials: two-body wear, gloss retention, roughness and martens hardness10.1016/j.jmbbm.2013.01.003 ↗
11. A comparative study of sliding wear of nonmetallic dental restorative materials with emphasis on micromechanical wear mechanisms10.1002/jbm.b.33193 ↗
12. In vitro evaluation of the wear resistance of composite resin blocks for CAD/CAM10.4012/dmj.2014-293 ↗
13. Wear behavior of pressable lithium disilicate glass ceramic10.1002/jbm.b.33447 ↗
14. Correlation of wear in vivo and six laboratory wear methods10.1016/j.dental.2012.04.006 ↗
15. Neale · 1973
16. Kato · 2001 · 273
17. Wear: mechanisms, manifestations and measurement. Report of a workshop10.1016/0300-5712(95)00043-7 ↗
18. Investigation on the tribological behavior and wear mechanism of five different veneering porcelains10.1371/journal.pone.0137566 ↗
19. Fatigue of dental ceramics10.1016/j.jdent.2013.10.007 ↗
20. Multi-crack analysis of hydraulically pumped cone fracture in brittle solids under cyclic spherical contact10.1007/s10704-006-9047-0 ↗
21. Sliding contact fracture of dental ceramics: principles and validation10.1016/j.actbio.2014.03.004 ↗
22. Damage maps for layered ceramics under simulated mastication10.1177/154405910808700706 ↗
23. Role of microstructure on contact damage and strength degradation of micaceous glass-ceramics10.1016/S0109-5641(98)00013-X ↗
24. Improving the resistance to sliding contact damage of zirconia using elastic gradients10.1002/jbm.b.31657 ↗
25. Wear of ceramic and antagonist—a systematic evaluation of influencing factors in vitro10.1016/j.dental.2007.06.016 ↗
26. Antagonist wear of monolithic zirconia crowns after 2 years10.1007/s00784-016-1872-6 ↗
27. Influence of clenching intensity on bite force balance, occlusal contact area, and average bite pressure10.1177/00220345990780070801 ↗
28. Wear of human enamel: a quantitative in vitro assessment10.1177/00220345980770120601 ↗
29. A comparative study on the wear behavior of a polymer infiltrated ceramic network (picn) material and tooth enamel10.1016/j.dental.2017.08.190 ↗
30. Polishing effects and wear performance of chairside CAD/CAM materials10.1007/s00784-018-2473-3 ↗
31. Wear of nanofilled dental composites at varying filler concentrations10.1002/jbm.b.33212 ↗
32. Friction and wear behaviors of indirect dental restorative composites10.1007/s11249-012-9921-z ↗
33. The mechanical properties of nanofilled resin-based composites: characterizing discrete filler particles and agglomerates using a micromanipulation technique10.1016/j.dental.2008.05.013 ↗
34. Influence of thermal cycling on flexural properties and simulated wear of computer-aided design/computer-aided manufacturing resin composites10.2341/16-046-L ↗
35. A comparative study of progressive wear of four dental monolithic, veneered glass-ceramics10.1016/j.jmbbm.2017.05.035 ↗
36. Friction and wear behaviors of dental ceramics against natural tooth enamel10.1016/j.jeurceramsoc.2012.03.021 ↗
37. Wear resistance and abrasiveness of CAD/CAM monolithic materials10.1016/j.prosdent.2018.05.011 ↗
38. Partial cone crack formation in a brittle material loaded with a sliding spherical indenter
39. Deep-penetrating conical cracks in brittle layers from hydraulic cyclic contact10.1002/jbm.b.30195 ↗
40. Effect of sliding friction forces on the strength of brittle materials10.1007/BF00550810 ↗
41. Sliding contact fatigue damage in layered ceramic structures10.1177/154405910708601105 ↗
42. Competing fracture modes in brittle materials subject to concentrated cyclic loading in liquid environments: monoliths10.1557/JMR.2005.0276 ↗
43. Competing fracture modes in brittle materials subject to concentrated cyclic loading in liquid environments: bilayer structures10.1557/JMR.2005.0335 ↗
44. Interpenetrating network ceramic-resin composite dental restorative materials10.1016/j.dental.2015.09.009 ↗
45. Mechanical properties of polymer-infiltrated-ceramic-network materials10.1016/j.dental.2013.01.002 ↗
46. Hertzian contact response and damage tolerance of dental ceramics10.1016/j.jmbbm.2014.02.002 ↗
47. Polymer infiltrated ceramic network structures for resistance to fatigue fracture and wear10.1016/j.dental.2016.08.216 ↗
48. R-curve behavior and micromechanisms of fracture in resin based dental restorative composites10.1016/j.jmbbm.2008.12.005 ↗
49. Resistance curves of short-fiber reinforced methacrylate-based biomedical composites10.1016/j.engfracmech.2017.12.008 ↗
50. Fatigue resistance of CAD/CAM resin composite molar crowns10.1016/j.dental.2015.12.005 ↗
51. Chairside CAD/CAM materials. Part 3: cyclic fatigue parameters and lifetime predictions10.1016/j.dental.2018.03.024 ↗
52. The stress field created by a circular sliding contact10.1115/1.3625051 ↗