journal article·2010-12

Impedance methodology: A new way to characterize the setting reaction of dental cements

Cyril Villat, V.X. Tran, Nelly Pradelle-Plasse, Pierre Ponthiaux, François Wenger, Brigitte Grosgogeat, Pierre Colon

Dental Materials· Volume 26· Issue 12
Publisher page

Abstract

Objectives Impedance spectroscopy is a non-destructive, quantitative method, commonly used nowadays for industrial research on cement and concrete. The aim of this study is to investigate the interest of impedance spectroscopy in the characterization of setting process of dental cements. Methods Two types of dental cements are used in this experiment: a new Calcium Silicate cement Biodentine™ (Septodont, Saint Maur-des Fossés, France) and a glass ionomer cement resin modified or not (Fuji II(®) LC Improved Capsules and Fuji IX(®) GP Fast set Capsules, GC Corp., Tokyo, Japan). The conductivity of the dental cements was determined by impedance spectroscopy measurements carried out on dental cement samples immersed in a 0.1M potassium chloride solution (KCl) in a "like-permeation" cell connected to a potentiostat and a Frequency Response Analyzer. The temperature of the solution is 37°C. From the moment of mixing of powder and liquid, the experiments lasted 2 weeks. Results The results obtained for each material are relevant of the setting process. For GIC, impedance values are stabilized after 5 days while at least 14 days are necessary for the calcium silicate based cement. Significance In accordance with the literature regarding studies of cements and concrete, impedance spectroscopy can characterize ion mobility, porosity and hardening process of dental hydrogel materials.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Endodontics and Root Canal Treatments · Electrical and Bioimpedance Tomography · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (17)

Show source-provided references
1. Cement paste hardening process studied by impedance spectroscopy10.1016/S0013-4686(99)00147-4 ↗
2. Evaluation of microleakage of composite resin restorations by an electrochemical technique: the impedance methodology10.1016/j.dental.2003.06.003 ↗
3. Analysis of reactions in glass–polyakenoate/resin systems by dielectric impedance spectroscopy10.1016/S0142-9612(97)00136-1 ↗
4. What do electrical conductivity and electrical modulus spectra tell us about the mechanisms of ion transport processes in melts, glasses, and crystals?10.1016/S0022-3093(98)00847-3 ↗
5. Impedance spectroscopy to characterize the pore structure during the hardening process of Portland cement paste10.1016/j.electacta.2005.02.125 ↗
6. Impedance spectroscopy study of hardened Portland cement paste10.1016/S0008-8846(02)00720-2 ↗
7. Application of impedance spectroscopy to cement-based materials: hydration of calcium phosphate bone cements10.4191/KCERS.2006.43.3.156 ↗
8. Evaluation of the effect of water-uptake on the impedance of dental resins10.1016/j.biomaterials.2006.01.045 ↗
9. Electrical conductivity, diffusion, and permeability of Portland cement-based mortars10.1016/S0008-8846(00)00281-7 ↗
10. Effect of temperature on electrical conductivity of blended cement pastes10.1016/S0008-8846(98)00198-7 ↗
11. Effect of moisture and sulphate contamination on the electrical resistivity of Portland cement concrete10.1016/0950-0618(95)00078-X ↗
12. A new translucent cement for dentistry: the glass ionomer cement10.1038/sj.bdj.4802810 ↗
13. Chemistry of glass-ionomer cements: a review10.1016/S0142-9612(97)00128-2 ↗
14. Resin-modified glass-ionomers10.1016/S0142-9612(98)00132-X ↗
15. Influence of glass composition on the properties of glass polyakenoate cements. Part I: influence of aluminium to silicon ratio10.1016/S0142-9612(99)00058-7 ↗
16. The use of acoustic microscopy to study the mechanical properties of glass ionomer cements10.1016/S0109-5641(03)00129-5 ↗
17. Electrical conductivity of drying cement paste10.1617/s11527-006-9211-z ↗