Effect of specimen gripping device, geometry and fixation method on microtensile bond strength, failure mode and stress distribution: Laboratory and finite element analyses
Source abstract
Abstract
Objectives Innumerous modifications have been proposed for the microtensile test since its introduction; however, testing parameters are not often well described and wide variations in bond strength are commonly reported. The aim of this study was to evaluate the effect of the test specimen's gripping device, specimen geometry and fixation method on microtensile bond strength, failure mode, and stress distribution when using an etch-and-rinse 2-step adhesive system bonded to human dentin. Methods Resin-based composite bonded to occlusal dentin from 21 human molars was used to fabricate dumbbell- and stick-shaped test specimens which were divided into three groups: Di - dumbbell-specimens placed in a Dircks device; GeS - stick-specimens gripped in a Geraldeli's device with Superglue; GeZ - stick-specimens gripped in a Geraldeli's device with Zapit. Specimens were tested to failure in tensile mode and the failure mode was examined under stereomicroscopy and fracture initiation sites were verified by scanning electron microscopy and energy dispersive X-ray spectroscopy. Three-dimensional models of each device/specimen were created and finite element calculations were performed. Results The effect of the gripping devices on the bond strength was not significant, unless the bond test areas were normalized. The failure mode was influenced by the type of device. Dircks device was less sensitive to human error than Geraldeli's, and produced a more uniform stress distribution at the dumbbell specimen adhesive layer than did the Geraldeli's device at the stick layer. Significance Microtensile testing parameters can directly influence the results and consequently inter-study comparisons.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Dental Health and Care Utilization · Dental Erosion and Treatment
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (53)
Show source-provided references
1. A critique of bond strength measurements10.1016/0300-5712(89)90131-0 ↗
2. The effect of local interfacial geometry on the measurement of the tensile bond strength to dentin10.1177/00220345910700050501 ↗
3. Relationship between surface area for adhesion and tensile bond strength-evaluation of a micro-tensile bond test10.1016/0109-5641(94)90067-1 ↗
4. Adhesion testing of dentin bonding agents: a review10.1016/0109-5641(95)80046-8 ↗
5. The microtensile bond test: a review
6. A tensile test to facilitate identification of defects in dentine bonded specimens10.1016/S0300-5712(97)00021-3 ↗
7. Failure analysis of resin composite bonded to ceramic10.1016/S0109-5641(03)00015-0 ↗
8. Fractography: determining the sites of fracture initiation10.1016/0109-5641(95)80045-X ↗
9. Effects of exogenous collagenase and cholesterol esterase on the durability of the resin–dentin bond
10. Mode of failure in the dentin-adhesive resin–resin composite bonded joint as determined by strength-based (muTBS) and fracture-based (CNSB) mechanical testing10.1016/S0109-5641(00)00070-1 ↗
11. Microtensile bond strength of a total-etch 3-step, total-etch 2-step, self-etch 2-step, and a self-etch 1-step dentin bonding system through 15-month water storage
12. Ultimate tensile strength of tooth structures10.1016/S0109-5641(03)00110-6 ↗
13. The effect of hybrid layer thickness on bond strength: demineralized dentin zone of the hybrid layer10.1016/S0109-5641(00)00035-X ↗
14. Microtensile bond strength testing and failure analysis of hybrid and flowable composites
15. In vivo influence of residual moisture on microtensile bond strengths of one-bottle adhesives10.1111/j.1708-8240.2002.tb00145.x ↗
16. The elastic moduli across various types of resin/dentin interfaces10.1016/j.dental.2007.12.008 ↗
17. Finite element analysis and bond strength of a glass post to intraradicular dentin: comparison between microtensile and push-out tests10.1016/j.dental.2008.03.004 ↗
18. Effects of mechanical properties of adhesive resins on bond strength to dentin10.1016/S0109-5641(01)00046-X ↗
19. Relationship between adhesive thickness and microtensile bond strength
20. Stress concentration in microtensile tests using uniform material
21. The effect of variations in hourglass specimen design on microtensile bond strength to dentin
22. Effect of cross-sectional surface area on bond strengths between resin and dentin10.1016/S0109-5641(98)00018-9 ↗
23. The influence of cross-sectional shape and surface area on the microtensile bond test10.1016/S0109-5641(98)00034-7 ↗
24. Regional measurement of resin–dentin bonding as an array10.1177/00220345990780021001 ↗
25. Bond angle effects on microtensile bonds: laboratory and FEA comparison10.1016/j.dental.2005.05.006 ↗
26. The influence of specimen attachment and dimension on microtensile strength10.1177/154405910408300513 ↗
27. Microtensile specimen attachment and shape-finite element analysis10.1177/154405910808700116 ↗
28. Influence of three specimen fixation modes on the micro-tensile bond strength of adhesives to dentin10.4012/dmj.26.694 ↗
29. Critical analysis of the influence of different parameters on the microtensile bond strength of adhesives to dentin
30. The influence of storage time and cutting speed on microtensile bond strength
31. Influence of method and period of storage on the microtensile bond strength of indirect composite resin restorations to dentine10.1590/S1806-83242008000400012 ↗
32. Resin–dentin bond strength as related to different surface preparation methods10.1016/j.jdent.2007.01.002 ↗
33. Microtensile bond strength tests: scanning electron microscopy evaluation of sample integrity before testing10.1034/j.1600-0722.2002.21317.x ↗
34. Influence of substrate, shape, and thickness on microtensile specimens’ structural integrity and their measured bond strengths10.1016/j.dental.2003.08.009 ↗
35. A novel method to obtain microtensile specimens minimizing cut flaws10.1002/jbm.b.30447 ↗
36. Influence of notch geometry and interface on stress concentration and distribution in micro-tensile bond strength specimens10.1016/j.jdent.2008.05.018 ↗
37. Laboratory and FEA evaluation of dentin-to-composite bonding as a function adhesive layer thickness10.1016/j.dental.2008.02.007 ↗
38. The influence of adhesive thickness on the microtensile bond strength of three adhesive systems
39. Evaluation of sources of uncertainties in microtensile bond strength of dental adhesive system for different specimen geometries10.1016/j.dental.2007.06.022 ↗
40. Influence of crosshead speed on resin–dentin microtensile bond strength
41. Effect of different cements on the biomechanical behavior of teeth restored with cast dowel-and-cores-in vitro and FEA analysis10.1111/j.1532-849X.2009.00527.x ↗
42. Effect of anti-rotation devices on biomechanical behaviour of teeth restored with cast post-and-cores10.1111/j.1365-2591.2010.01739.x ↗
43. Influence of specimen designs on the microtensile bond strength to dentin
44. Influence of joint component mechanical properties and adhesive layer thickness on stress distribution in micro-tensile bond strength specimens10.1016/j.dental.2008.04.009 ↗
45. Micromechanical analysis of dentin/adhesive interface by the finite element method10.1002/jbm.b.30012 ↗
46. Adhesion to tooth structure: a critical review of “micro” bond strength test methods10.1016/j.dental.2009.11.155 ↗
47. Analysis of tensile bond strengths using Weibull statistics10.1016/j.biomaterials.2004.01.060 ↗
48. Direct comparison of the bond strength results of the different test methods: a critical literature review10.1016/j.dental.2009.12.002 ↗
49. Influence of restorative technique on the biomechanical behavior of endodontically treated maxillary premolars. Part II: strain measurement and stress distribution10.1016/S0022-3913(08)60027-X ↗
50. Dynamic and static moduli of elasticity of resin-based materials10.1016/S0109-5641(01)00021-5 ↗
51. Measurement of Poisson's ratio of dental composite restorative materials10.1016/j.biomaterials.2003.09.029 ↗
52. Macroscopic modeling of fine line adhesion test10.1557/PROC-563-297 ↗
53. Optical fibre sensor for health monitoring of bonded repair systems10.1016/S0263-8223(00)00107-0 ↗