Alternative methods for determining shrinkage in restorative resin composites
Source abstract
Abstract
Objectives The purpose of this study was to evaluate polymerization shrinkage of resin composites using a coordinate measuring machine, optical coherence tomography and a more widely known method, such as Archimedes Principle. Two null hypothesis were tested: (1) there are no differences between the materials tested; (2) there are no differences between the methods used for polymerization shrinkage measurements. Methods Polymerization shrinkage of seven resin-based dental composites (Filtek Z250™, Filtek Z350™, Filtek P90™/3M ESPE, Esthet-X™, TPH Spectrum™/Dentsply 4 Seasons™, Tetric Ceram™/Ivoclar-Vivadent) was measured. For coordinate measuring machine measurements, composites were applied to a cylindrical Teflon mold (7 mm × 2 mm), polymerized and removed from the mold. The difference between the volume of the mold and the volume of the specimen was calculated as a percentage. Optical coherence tomography was also used for linear shrinkage evaluations. The thickness of the specimens was measured before and after photoactivation. Polymerization shrinkage was also measured using Archimedes Principle of buoyancy (n=5). Statistical analysis of the data was performed with ANOVA and the Games-Howell test. Results The results show that polymerization shrinkage values vary with the method used. Despite numerical differences the ranking of the resins was very similar with Filtek P90 presenting the lowest shrinkage values. Significance Because of the variations in the results, reported values could only be used to compare materials within the same method. However, it is possible rank composites for polymerization shrinkage and to relate these data from different test methods. Independently of the method used, reduced polymerization shrinkage was found for silorane resin-based composite.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Optical Coherence Tomography Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (42)
Show source-provided references
1. Kinetic model for the coupled volumetric and thermal behavior of dental composites10.1016/j.dental.2007.11.023 ↗
2. A model for shrinkage strain in photo polymerization of dental composites10.1016/j.dental.2007.11.015 ↗
3. Polymerization shrinkage and contraction stress of dental resin composites10.1016/j.dental.2005.02.004 ↗
4. Determinants of in vitro gap formation of resin composites10.1016/j.jdent.2003.08.008 ↗
5. Assessment of polymerization contraction stress of three composite resins10.1016/j.dental.2007.06.031 ↗
6. Axial shrinkage-stress depends upon both C-factor and composite mass10.1016/j.dental.2007.08.007 ↗
7. Silorane-based dental composite: behavior and abilities10.4012/dmj.25.445 ↗
8. Critical configuration analysis of four methods for measuring polymerization shrinkage strain of composites10.1016/j.dental.2003.11.002 ↗
9. Determination of polymerization shrinkage kinetics in visible-light-cured materials: methods development10.1016/S0109-5641(05)80030-2 ↗
10. A modified dilatometer for continuous recording of volumetric polymerization shrinkage of composite restorative materials10.1016/0300-5712(81)90033-6 ↗
11. Volumetric shrinkage of composites using video-imaging10.1016/S0300-5712(03)00005-8 ↗
12. Comparison of two video-imaging instruments for measuring volumetric shrinkage of dental resin composites10.1016/j.jdent.2005.02.004 ↗
13. Polymerization shrinkage evaluation of three packable composite resins using a gas pycnometer10.1590/S1517-74912003000300013 ↗
14. Comparative analysis of the shrinkage stress of composite resins10.1590/S1678-77572008000100007 ↗
15. An overview on the kinematic modeling of coordinate measuring machines (CMMs)
16. Assessment of shoulder dimensions and angles of porcelain bonded to metal crown preparations10.1016/S0022-3913(96)90033-5 ↗
17. Optical approach to the periodontal ligament under orthodontic tooth movement: a preliminary study with optical coherence tomography10.1016/j.ajodo.2007.10.037 ↗
18. Identification of occlusal sealants using optical coherence tomography
19. Volumetric dimensional change of six direct core materials10.1016/S0109-5641(03)00127-1 ↗
20. Polymerization shrinkage and hygroscopic expansion of contemporary posterior resin-based filling materials—a comparative study10.1016/j.jdent.2007.07.014 ↗
21. A partially aromatic urethane dimethacrylate as a new substitute for Bis-GMA in restorative composites10.1016/j.dental.2007.07.001 ↗
22. Contemporary issues in photocuring
23. Polymerization contraction stress of low-shrinkage composites and its correlation with microleakage in class V restorations10.1016/j.jdent.2004.01.014 ↗
24. Rasband · 2006
25. Siloranes in dental composites10.1016/j.dental.2004.10.007 ↗
26. Polymerization shrinkage and polymerization shrinkage stress in polymer-based restoratives10.1016/S0300-5712(96)00063-2 ↗
27. Time-resolved simultaneous measurement of group index and physical thickness during photopolymerization of resin-based dental composite10.1117/1.2709877 ↗
28. Evaluation of enamel dental restoration interface by optical coherence tomography10.1117/1.2141617 ↗
29. Time dependence of composite shrinkage using halogen and LED light curing10.1016/j.dental.2004.03.010 ↗
30. German Standard DIN 13907:2007, Zahnheilkunde – Polymerisationsschrumpfung von Füllungswerkstoffen.
31. Physical properties of a new silorane-based restorative system10.1016/j.dental.2009.12.004 ↗
32. Properties of hybrid resin composite systems containing prepolymerized filler particles10.2341/08-118-L ↗
33. Polymerization shrinkage-strain and microleakage in dentin-bordered cavities of chemically and light-cured restorative materials10.1016/S0109-5641(01)00078-1 ↗
34. Setting characteristics and cavity adaptation of low-shrinking resin composites10.1016/j.dental.2009.06.022 ↗
35. Macro-, micro- and nano-mechanical investigations on silorane and methacrylate-based composites10.1016/j.dental.2009.02.005 ↗
36. 3M ESPE, Filtek LS technical profile, 2009; http://multimedia.com/mws/mediaserver
37. Contraction stress of low-shrinkage composite materials assessed with different testing systems10.1016/j.dental.2010.05.007 ↗
38. Update on dental nanocomposites
39. Influence of matrix composition on polymerization stress development of experimental composites10.1016/j.dental.2010.03.014 ↗
40. Effect of photo-activation method upon polymerization shrinkage of restorative composites
41. The volumetric fraction of inorganic particles and the flexural strength of composites for posterior teeth10.1016/S0300-5712(03)00049-6 ↗
42. Investigating filler morphology and mechanical properties of new low-shrinkage resin composite10.1111/j.1365-2842.2010.02066.x ↗