Monolithic crowns fracture analysis: The effect of material properties, cusp angle and crown thickness
Source abstract
Abstract
Objectives This study aimed to investigate the collective influence of material properties and design parameters on the fracture behavior of monolithic dental crowns. Methods Three-dimensional (3D) models (N=90) with different combinations of design parameters (thickness, cusp angle and occlusal notch geometry) and material type (lithium disilicate, feldspar ceramic, zirconia, hybrid resin ceramic and hybrid polymer-infiltrated ceramic) were developed for the failure analysis using extended finite element method (XFEM) to identify the stress distribution, crack initiation load, fracture surface area and fracture pattern. Analytical formulation, in vitro fracture tests and fractographic analysis of dedicated models were also performed to validate the findings of the XFEM simulation. Results For all material types considered, crowns with a sharp occlusal notch design had a significantly lower fracture resistance against occlusal loading. In most of the models, greater crown thickness and cusp angle resulted in a higher crack initiation load. However, the effect of cusp angle was dominant when the angle was in the low range of 50° for which increasing thickness did not enhance the crack initiation load. Significance Comparing the critical load of crack initiation for different models with the maximum biting force revealed that for the studied monolithic materials excluding zirconia, a design with a rounded occlusal notch, 70° cusp angle and medium thickness (1.5mm occlusal) is an optimum combination of design parameters in terms of tooth conservation and fracture resistance. Zirconia crowns exhibited sufficient strength for a more conservative design with less thickness (1.05mm occlusal) and sharper cusp angle (60°).
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Dental Health and Care Utilization
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (44)
Show source-provided references
1. Microstructural and mechanical characterization of CAD/CAM materials for monolithic dental restorations10.1111/jopr.12964 ↗
2. Optical properties of CAD–CAM ceramic systems10.1016/j.jdent.2014.07.005 ↗
3. Surface quality of yttria-stabilized tetragonal zirconia polycrystal in CAD/CAM milling, sintering, polishing and sandblasting processes10.1016/j.jmbbm.2016.08.021 ↗
4. Trade-off between fracture resistance and translucency of zirconia and lithium-disilicate glass ceramics for monolithic restorations10.1016/j.actbio.2019.04.043 ↗
5. Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures10.1016/j.actbio.2008.12.016 ↗
6. The clinical success of all-ceramic restorations10.14219/jada.archive.2008.0361 ↗
7. Basu · 2011
8. Dental biomaterials for chairside CAD/CAM: state of the art10.4047/jap.2017.9.6.486 ↗
9. Mechanical properties of polymer-infiltrated-ceramic-network materials10.1016/j.dental.2013.01.002 ↗
10. Resin-composite blocks for dental CAD/CAM applications10.1177/0022034514553976 ↗
11. Influence of restoration thickness and dental bonding surface on the fracture resistance of full-coverage occlusal veneers made from lithium disilicate ceramic10.1016/j.dental.2015.04.017 ↗
12. CAD-FEA modeling and analysis of different full crown monolithic restorations10.1016/j.dental.2018.06.024 ↗
13. Edge strength of CAD/CAM materials10.1016/j.jdent.2018.05.004 ↗
14. Anusavice · 2012
15. Towards automated 3D finite element modeling of direct fiber reinforced composite dental bridge10.1002/jbm.b.30233 ↗
16. Sensitivity analysis of bi-layered ceramic dental restorations10.1016/j.dental.2011.11.012 ↗
17. Effects of design parameters on fracture resistance of glass simulated dental crowns10.1016/j.dental.2015.11.018 ↗
18. Mechanical benefits of conservative restoration for dental fissure caries10.1016/j.jmbbm.2015.08.010 ↗
19. Role of implant configurations supporting three-unit fixed partial denture on mandibular bone response: biological-data-based finite element study10.1111/joor.12411 ↗
20. Effect of configurations of implants supporting a four-unit fixed partial denture on loading distribution10.11607/ijp.5033 ↗
21. Evolutionary aspects of reptilian and mammalian enamel structure
22. Quantitative characterization and micro-CT mineral mapping of natural fissural enamel lesions10.1016/j.jdent.2016.01.012 ↗
23. Comparison of mechanical property and role between enamel and dentin in the human teeth10.1177/1758736014520809 ↗
24. Ultimate tensile strength of tooth structures10.1016/S0109-5641(03)00110-6 ↗
25. The all-ceramic, inlay supported fixed partial denture. Part 5. Extended finite element analysis validation10.1111/adj.12107 ↗
26. Modelling of stress distribution and fracture in dental occlusal fissures10.1038/s41598-019-41304-z ↗
27. Mohammadi · 2008
28. Fracture resistance of teeth restored with dentin-bonded crowns
29. Thermally induced fracture for core-veneered dental ceramic structures10.1016/j.actbio.2013.05.009 ↗
30. Riedel · 2008
31. A review of extended/generalized finite element methods for material modeling10.1088/0965-0393/17/4/043001 ↗
32. Competition of fracture mechanisms in monolithic dental ceramics: flat model systems10.1002/jbm.b.31100 ↗
33. Influence of occlusal geometry on ceramic crown fracture; role of cusp angle and fissure radius10.1016/j.jmbbm.2011.03.014 ↗
34. Influence of cusp inclination and curvature on the in vitro failure and fracture resistance of veneered zirconia crowns10.1007/s00784-013-1029-9 ↗
35. Surface roughness and the flexural and bend strength of zirconia after different surface treatments10.1016/j.prosdent.2016.02.018 ↗
36. Bite force and state of dentition10.3109/00016357709064128 ↗
37. Fracture-resistant monolithic dental crowns10.1016/j.dental.2015.12.010 ↗
38. A wide range stress intensity factor expression for the C-shaped specimen10.1520/JTE10631J ↗
39. Tada · 2000
40. Fracture behaviors of monolithic lithium disilicate ceramic crowns with different thicknesses10.1039/C6RA28847B ↗
41. Load-bearing capacity and the recommended thickness of dental monolithic zirconia single crowns10.1016/j.jmbbm.2014.03.014 ↗
42. Relative flexural strength of dental restorative ceramics10.1016/0109-5641(90)90026-B ↗
43. Strength of CAD/CAM-generated esthetic ceramic molar implant crowns
44. Zirconia-reinforced lithium silicate crowns: effect of thickness on survival and failure mode10.1016/j.dental.2019.04.007 ↗