journal article·2014-08

Full-arch prostheses from translucent zirconia: Accuracy of fit

Caroline Sachs, Julian Groesser, Markus Stadelmann, Josef Schweiger, Kurt Erdelt, Florian Beuer

Dental Materials· Volume 30· Issue 8
Publisher page

Abstract

Objectives The aim of this study was to evaluate the marginal and internal fit of single crowns, compared to 14-unit frameworks made of translucent yttria-stabilized zirconia. We hypothesized that there is an influence of the type of restoration on the marginal and internal fit. Methods Eight teeth (FDI locations 17, 15, 13, 11, 21, 23, 25 and 27) of a typodont maxillary model were provided with a chamfer preparation to accommodate a 14-unit prosthesis or four single crowns (SCs). Ten 14-unit fixed dental prostheses (FDPs) and 40 single crowns were fabricated using a computer aided design (CAD)/computer aided manufacturing (CAM) system with pre-sintered translucent yttria-stabilized zirconia blanks. The restorations were cemented onto twenty master dies, which were sectioned into four pieces each. Then, the marginal and internal fits were examined using a binocular microscope. In order to detect the differences between the two types of restorations a non-parameteric test (Mann-Whitney-U) was carried out; to detect differences between the abutment teeth and the abutment surfaces non-parametric tests (Kruskal-Wallis) and pairwise post hoc analyses (Mann-Whitney-U) were performed after testing data for normal distribution (method according to Shapiro-Wilk). Level of significance was set at 5%. Results The mean (SD) marginal opening gap dimensions were 18 μm (14) for the single crowns and 29 μm (27) for the 14-unit FDPs (p<0.001). Abutment 21 of the FDPs showed statistical differences concerning the location of the teeth in both marginal and internal fit (p<0.001). The measured gaps (types I-IV) revealed statistical differences between all types, when comparing SCs to the FDPs (p<0.001). Significance Single crowns showed significantly better accuracy of fit, compared to the 14-unit FDPs. However, both restorations showed clinically acceptable marginal and internal fit.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Dental Implant Techniques and Outcomes · Endodontics and Root Canal Treatments

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (34)

Show source-provided references
1. The effect of zirconia sintering temperature on flexural strength, grain size, and contrast ratio10.1007/s00784-012-0692-6 ↗
2. Clinical performance and failures of zirconia-based fixed partial dentures: a review literature10.4047/jap.2012.4.2.76 ↗
3. Digital dentistry: an overview of recent developments for CAD/CAM generated restorations10.1038/sj.bdj.2008.350 ↗
4. Load-bearing capacity of all-ceramic posterior four-unit fixed partial dentures with different zirconia frameworks10.1111/j.1600-0722.2007.00429.x ↗
5. Lifetime of alumina- and zirconia ceramics used for crown and bridge restorations10.1002/jbm.b.30599 ↗
6. Holzner, S, Weber, G. Material and blank for dentures. EP Patent No 2034947; 2011.
7. Frank, SHH, Moscheler, S, Schnagl, R, Suttor, D. Method of producing a dental prosthesis. US Patent No 0119180; 2004.
8. Sintering behavior and mechanical properties of zirconia compacts fabricated by uniaxial press forming10.4047/jap.2010.2.3.81 ↗
9. Young-Jung, K. Biaxial press molding system. US Patent No 6890168; 2005.
10. Marginal fit of 14-unit zirconia fixed dental prosthesis retainers10.1111/j.1365-2842.2008.01908.x ↗
11. Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations10.1111/j.1365-2842.2005.01446.x ↗
12. Clinical fit of four-unit zirconia posterior fixed dental prostheses10.1111/j.1600-0722.2008.00580.x ↗
13. Fit of three porcelain-fused-to-metal marginal designs in vivo: a scanning electron microscope study10.1016/0022-3913(85)90058-7 ↗
14. The fit of Procera titanium crowns. An in vitro and clinical study10.3109/00016359309041158 ↗
15. The estimation of cement film thickness by an in vivo technique10.1038/sj.bdj.4802708 ↗
16. A comparison of the marginal fit of In-Ceram, IPS Empress, and Procera crowns
17. Marginal fit of porcelain-fused-to-metal and two types of ceramic crown10.1016/0022-3913(90)90260-J ↗
18. Marginal adaptation of castable ceramic crowns10.1016/0022-3913(91)90408-O ↗
19. Effect of in vivo crown margin discrepancies on periodontal health10.1016/0022-3913(91)90225-L ↗
20. Clinical and microbiological effects of subgingival restorations with overhanging or clinically perfect margins10.1111/j.1600-051X.1983.tb01295.x ↗
21. A survey of crown and fixed partial denture failures: length of service and reasons for replacement10.1016/0022-3913(86)90379-3 ↗
22. Clinical acceptability of crown margins versus marginal gaps as determined by pre-doctoral students and prosthodontists10.1111/j.1532-849X.2005.00048.x ↗
23. The effect of cement thickness on the fracture strength of all-ceramic crowns10.1111/j.1834-7819.1995.tb05607.x ↗
24. Evaluation of hardness and fracture toughness, coupled with microstructural analysis, of zirconia ceramics stored in environments with different pH values10.4012/dmj.2012-005 ↗
25. Effect of preparation design on the fracture resistance of zirconia crown copings10.4012/dmj.27.362 ↗
26. Marginal and internal fits of fixed dental prostheses zirconia retainers10.1016/j.dental.2008.04.018 ↗
27. Crowns cemented on crown preparations lacking geometric resistance form. Part II: effect of cement10.1111/j.1532-849X.2004.04008.x ↗
28. Results of a prospective randomized controlled trial of posterior ZrSiO(4)-ceramic crowns10.1111/j.1365-2842.2008.01918.x ↗
29. Stresses and distortions within zirconia-fixed dental prostheses due to the veneering process10.1016/j.actbio.2009.04.025 ↗
30. Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems10.1111/j.1600-0722.2009.00622.x ↗
31. Marginal adaptation of three different zirconium dioxide three-unit fixed dental prostheses10.1016/S0022-3913(09)60047-0 ↗
32. Influence of the veneering process on the marginal fit of zirconia fixed dental prostheses10.1111/j.1365-2842.2009.02053.x ↗
33. Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems10.1111/j.1600-0722.2004.00197.x ↗
34. Precision of fit: zirconia three-unit fixed dental prostheses10.1007/s00784-008-0224-6 ↗