Modification of the restoration protocol for resin-based composite (RBC) restoratives (conventional and bulk fill) on cuspal movement and microleakage score in molar teeth
Source abstract
Abstract
Objective To modify the resin-based composite (RBC) restoration protocol for standardised Class II cavities in third molar teeth restored using conventional RBCs or their bulk fill restorative counterparts. Employing cuspal deflection using a twin channel deflection measuring gauge (during) and microleakage to determine marginal integrity (following) RBC restoration, the modified restoration protocol results were compared with traditional (oblique) restoration of Class II cavities. Methods Thirty-two sound third molar teeth, standardised by size and morphology, were subjected to standardised Class II cavity preparations and randomly allocated to four groups. Restorations were placed in conjunction with a universal bonding system and resin restorative materials were irradiated with a light-emitting-diode light-curing-unit. The cumulative buccal and palatal cuspal movements from a twin channel deflection measuring gauge were summed, the restored teeth fatigued thermally prior to immersion in 0.2% basic fuchsin dye for 24h, before sectioning and examination for microleakage. Results Teeth restored using conventional RBC materials had significantly higher mean total cuspal movement values compared with bulk fill resin restorative restoration (all p<0.0001). Teeth restored with Admira Fusion and Admira Fusion x-tra had significantly the lowest microleakage scores (all p<0.001) compared with Tetric EvoCeram and Tetric EvoCeram Bulk Fill restored teeth. The microleakage scores for the range of RBC materials tested were significantly reduced (all p<0.001) when the modified RBC restoration protocol was employed compared with the traditional Class II restoration technique. Significance Modification of the RBC restoration protocol of some conventional RBCs and bulk fill resin restoratives significantly improve bond integrity and could be translated as a validation of the limited clinical studies available on bulk fill materials in the dental literature where Class II cavities perform less well than Class I cavities following extended follow-up. Clinical significance The results of the current study add further weight to experimental protocols employing cuspal movement (during) and cervical microleakage (following) RBC restoration of standardised cavities in natural dentition to provide an indication of polymerization shrinkage stress at the tooth/RBC restoration interface in a 'clinically meaningful context'.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Dental Health and Care Utilization · Dental Research and COVID-19
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (59)
Show source-provided references
1. The amalgam-free dental school10.1016/j.jdent.2004.02.008 ↗
2. Five-year clinical performance of posterior resin composite restorations placed by dental students10.1016/j.jdent.2004.02.005 ↗
3. Amalgam to tooth-coloured materials–implications for clinical practice and dental education: governmental restrictions and amalgam-usage survey results10.1016/j.jdent.2004.02.003 ↗
4. Academy of operative dentistry European section: Guidance on the use of resin composites for direct restoration of posterior teeth10.1016/j.jdent.2014.01.009 ↗
5. The teaching of posterior resin composites: planning for the future based on 25 years of research
6. Outcome of direct restorations placed within the general dental services in England and Wales (Part 1): variation by type of restoration and re-intervention10.1016/j.jdent.2005.03.008 ↗
7. Amalgam and resin composite longevity of posterior restorations: a systematic review and meta-analysis10.1016/j.jdent.2015.06.005 ↗
8. Patient acceptance of posterior composite restorations
9. Time required for placement of composite versus amalgam restorations
10. Bulk fill restoratives: to cap or not to cap—that is the question?10.1016/j.jdent.2015.01.010 ↗
11. Shining a light on high volume photocurable materials10.1016/j.dental.2018.02.009 ↗
12. Clinical evaluation of the posterior composite Quixfil in class I and II cavities: 4-year follow-up of a randomized controlled trial
13. A randomized controlled three year evaluation of “bulk-filled” posterior resin restorations based on stress decreasing resin technology10.1016/j.dental.2014.05.028 ↗
14. Randomized 3-year clinical evaluation of Class I and II posterior resin restorations placed with a bulk-fill resin composite and a one-step self-etching adhesive
15. Posterior bulk-filled resin composite restorations: a 5-year randomized controlled clinical study10.1016/j.jdent.2016.05.008 ↗
16. Bulk-filled posterior resin restorations based on stress-decreasing resin technology: a randomized, controlled 6-year evaluation10.1111/eos.12351 ↗
17. Dynamics of composite polymerization mediates the development of cuspal strain10.1016/j.dental.2005.11.017 ↗
18. Cuspal deflection and microleakage in premolar teeth restored with bulk-fill flowable resin-based composite base materials10.1016/j.jdent.2012.02.015 ↗
19. Implications of resin-based composite (RBC) restoration on cuspal deflection and microleakage score in molar teeth: placement protocol and restorative material10.1016/j.dental.2017.06.001 ↗
20. Cuspal deflection and cervical microleakage scores to determine the adhesive potential of universal bonding systems10.1016/j.jdent.2014.05.013 ↗
21. The adhesive potential of dentin bonding systems assessed using cuspal deflection measurements and cervical microleakage scores10.1016/j.dental.2014.07.005 ↗
22. Adhesion to and decalcification of hydroxyapatite by carboxylic acids10.1177/00220345010800061701 ↗
23. Adhesion/decalcification mechanisms of acid interactions with human hard tissues10.1002/jbm.1216 ↗
24. A survey of cusp fractures in a population of general dental practices
25. Product specification for Futurabond Universal Adhesive (Voco GmbH, Cuxhaven, Germany).
26. Product specification for Tetric EvoCeram RBC (Ivoclar Vivadent, Schaan, Lichtenstein).
27. Product specification for Admira Fusion (Voco, Cuxhaven, Germany).
28. Product specification for Tetric EvoCeram Bulk Fill (Ivoclar Vivadent, Schaan, Lichtenstein).
29. Product specification for Admira Fusion x-tra (Voco, Cuxhaven, Germany).
30. Statistical methodology in oral and dental research: pitfalls and recommendations10.1016/j.jdent.2013.02.013 ↗
31. Thermal cycling procedures for laboratory testing of dental restorations10.1016/S0300-5712(98)00037-2 ↗
32. ISO · 2003
33. ISO · 2004
34. Cuspal movement in premolar teeth restored with a packable composite cured in bulk or incrementally10.1016/S0300-5712(02)00121-5 ↗
35. Cuspal movement and microleakage in premolar teeth restored with posterior filling materials of varying reported volumetric shrinkage values10.1016/j.jdent.2004.09.007 ↗
36. In vitro cuspal deflection and microleakage of maxillary premolars restored with novel low-shrink dental composites10.1016/j.dental.2004.05.005 ↗
37. Investigation of polymeristaion shrinkage strain, associated cuspal movement and microleakage of MOD cavities restored incrementally with resin-based composite using an LED light curing unit10.1016/j.jdent.2006.05.003 ↗
38. Cuspal movement and microleakage in premolar teeth restored with resin-based filling materials cured using a ‘soft-start’ polymerisation protocol10.1016/j.dental.2006.06.002 ↗
39. Cuspal deflection and microleakage in premolar teeth restored with resin-based composites with and without an intermediary flowable layer10.1016/j.jdent.2007.01.005 ↗
40. Influence of resin-based composite restoration technique and endodontic access on cuspal deflection and cervical microleakage scores10.1016/j.jdent.2012.11.002 ↗
41. Reduced polymerization stress of MAPO-containing resin composites with increased curing speed, degree of conversion and mechanical properties10.1016/j.dental.2014.02.003 ↗
42. Photo-polymerization shrinkage-stress kinetics in resin-composites: methods development10.1016/S0109-5641(02)00123-9 ↗
43. True linear polymerization shrinkage of unfilled resins and composites determined with a linometer10.1016/0109-5641(93)90097-A ↗
44. Determination of polymerization kinetics in visible-light cured materials: methods development10.1016/S0109-5641(05)80030-2 ↗
45. Bond strength tests of dental adhesive systems and their correlation with clinical results—a meta-analysis10.1016/j.dental.2015.01.011 ↗
46. The competition between the composite-dentin bond strength and the polymerisation contraction stress10.1177/00220345840630121101 ↗
47. Relationship between bond-strength tests and clinical outcomes10.1016/j.dental.2009.11.148 ↗
48. State of the art of self-etch adhesives10.1016/j.dental.2010.10.023 ↗
49. Reduction in tooth stiffness as a result of endodontic and restorative procedures10.1016/S0099-2399(89)80191-8 ↗
50. Stiffness of endodontically-treated teeth related to restoration technique10.1177/00220345890680111401 ↗
51. Biomechanics of the intact, prepared and restored tooth: some clinical implications
52. Influence of cavity dimension and restoration methods on the cusp deflection of premolars in composite restoration10.1016/j.dental.2006.01.025 ↗
53. Spatially resolved assessment of composite shrinkage in MOD restorations using a digital-image-correlation technique10.1016/j.dental.2010.09.008 ↗
54. Curing light performance and polymerization of composite restorative materials10.1016/0300-5712(92)90136-Z ↗
55. Residual shrinkage stress distributions in molars after composite restoration10.1016/j.dental.2003.05.007 ↗
56. Does an incremental filling technique reduce polymerization shrinkage stresses?10.1177/00220345960750030301 ↗
57. Influence of cavity dimensions and their derivatives (volume and ‘C’ factor) on shrinkage stress development and microleakage of composite restorations10.1016/j.dental.2005.11.010 ↗
58. Systematic reviews. I. The correlation between laboratory tests on marginal quality and bond strength. II. The outcome between marginal quality and clinical outcome
59. In vitro comparison of polymerisation kinetics and the micro-mechanical properties of low and high viscosity giomers and RBC materials10.1016/j.jdent.2015.04.009 ↗