journal article·2021-07

Mechanical degradation of contemporary CAD/CAM resin composite materials after water ageing

Michael Wendler, Anja Stenger, Julian Ripper, Eva Priewich, Renan Belli, Ulrich Lohbauer

Dental Materials· Volume 37· Issue 7
Publisher page

Abstract

Objective The aim of the present study was to assess the effect of water storage on the quasi-static properties and cyclic fatigue behavior of four contemporary CAD/CAM resin composite materials. Methods The CAD/CAM resin composites Grandio Blocs, LavaTM Ultimate, CerasmartTM and Brilliant Crios, as well as the direct resin composite Grandio SO, were evaluated. Rectangular plates were cut from the blocks or fabricated using a silicon mold to obtain specimens for fracture toughness (KIc, n = 10), biaxial strength (σ0, n = 30) and cyclic fatigue testing (n = 30). Half of the specimens was stored for 24 h in dry conditions and the other half was aged for 60 days in distilled water at 37 °C. KIc was determined using the Compact-Tension (C(T)) method and σ0 and cyclic fatigue were tested using the Ball-on-Three-Balls assembly. Additional disc-shaped specimens (n = 5) were produced to obtain water sorption curves of the materials. Weibull statistics and two-way ANOVA with Tukey's post-hoc test were used for data assessment. Results The highest water sorption was observed for LavaTM Ultimate (42.6 μg/mm3), whereas Grandio SO displayed the lowest uptake (14 μg/mm3). A statistically significant drop in KIc and σ0 was measured for all materials after water storage, except for the σ0 of CerasmartTM. Water ageing had a dissimilar effect on the cyclic fatigue behavior, increasing the slow crack growth susceptibility of LavaTM Ultimate, but decreasing it for CerasmartTM and Brilliant Crios. Significance Contemporary CAD/CAM resin composites are susceptible to water driven degradative processes, although differences in filler content and resin matrix constitution play an important role in how it impacts their mechanical properties.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Epoxy Resin Curing Processes · Mechanical Behavior of Composites

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (50)

Show source-provided references
1. The future of dental devices is digital10.1016/j.dental.2011.10.014 ↗
2. Chairside computer-aided direct ceramic inlays
3. Composite inlay: research model with potential application in the dental practice? [original in German: Kompositinlay: Forschungsmodell mit Praxispotential?]
4. Fatigue behaviour of dental composite materials10.1016/j.jdent.2008.12.008 ↗
5. Resin-composite blocks for dental CAD/CAM applications10.1177/0022034514553976 ↗
6. Machinability of CAD-CAM materials10.1016/j.prosdent.2016.09.022 ↗
7. Brittleness index of machinable dental materials and its relation to the marginal chipping factor10.1016/j.jdent.2007.07.002 ↗
8. Mechanical properties of resin-ceramic CAD/CAM restorative materials10.1016/j.prosdent.2015.04.016 ↗
9. Uniaxial/biaxial flexure strengths and elastic properties of resin-composite block materials for CAD/CAM10.1016/j.dental.2018.11.032 ↗
10. Mechanical properties and internal fit of 4 CAD-CAM block materials10.1016/j.prosdent.2017.03.001 ↗
11. Hygroscopic and hydrolytic effects in dental polymer networks10.1016/j.dental.2005.05.005 ↗
12. Study of water sorption, solubility and modulus of elasticity of light-cured dimethacrylate-based dental resins10.1016/S0142-9612(02)00380-0 ↗
13. In vitro aging of dental composites in water—effect of degree of conversion, filler volume, and filler/matrix coupling10.1002/(SICI)1097-4636(19981205)42:3<465::AID-JBM17>3.0.CO;2-F ↗
14. R-curve behavior and toughening mechanisms of resin-based dental composites: effects of hydration and post-cure heat treatment10.1016/j.dental.2008.12.004 ↗
15. Practical and theoretical considerations on the fracture toughness testing of dental restorative materials10.1016/j.dental.2017.11.016 ↗
16. ISO 4049 · 2009
17. ASTM-E1820-13 · 2013
18. Chairside CAD/CAM materials. Part 2: flexural strength testing10.1016/j.dental.2016.10.008 ↗
19. Chairside CAD/CAM materials. Part 1: measurement of elastic constants and microstructural characterization10.1016/j.dental.2016.10.009 ↗
20. Munz · 2001
21. Determination of d a/d N-ΔK1 curves for small cracks in alumina in alternating bending tests10.1007/BF01124680 ↗
22. Water sorption characteristics of light-cured dental resins and composites based on Bis-EMA/PCDMA10.1016/S0142-9612(03)00529-5 ↗
23. Evaluation of five CAD/CAM materials by microstructural characterization and mechanical tests: a comparative in vitro study10.1186/s12903-017-0458-2 ↗
24. The effects of adding various ratios of zirconium oxide nanoparticles to poly(methyl methacrylate) on physical and mechanical properties10.2334/josnusd.17-0206 ↗
25. Discoloration of various CAD/CAM blocks after immersion in coffee10.5395/rde.2017.42.1.9 ↗
26. Fractography of clinically fractured, implant-supported dental computer-aided design and computer-aided manufacturing crowns
27. 3M ESPE, Change in Indication—Lava Ultimate Restorative. http://multimedia.3m.com/mws/media/1198023O/lava-ultimate-restorative-change-of-indication-notice.pdf. [Accessed 30 November 2020].
28. Resin composite blocks via high-pressure high-temperature polymerization10.1016/j.dental.2011.12.003 ↗
29. Properties of experimental urethane dimethacrylate-based dental resin composite blocks obtained via thermo-polymerization under high pressure10.1016/j.dental.2013.02.006 ↗
30. Fatigue behavior of resin composites in aqueous environments10.1016/j.dental.2006.06.031 ↗
31. Factors involved in mechanical fatigue degradation of dental resin composites10.1177/0022034513490734 ↗
32. Fracture resistance curves and toughening mechanisms in polymer based dental composites10.1016/j.jmbbm.2011.01.003 ↗
33. R-curve behavior and micromechanisms of fracture in resin based dental restorative composites10.1016/j.jmbbm.2008.12.005 ↗
34. Fracture toughness analysis of ceramic and resin composite CAD/CAM material10.2341/18-161-L ↗
35. Fracture toughness, flexural strength, and flexural Modulus of new CAD/CAM resin composite blocks10.1111/jopr.13123 ↗
36. Investigations on mechanical behaviour of dental composites10.1007/s00784-009-0258-4 ↗
37. Fracture toughness of dental restorative materials10.1007/s00784-011-0525-z ↗
38. Effect of monomer structure on the mechanical properties of light-cured composite resins10.4012/dmj.8.40 ↗
39. Effect of storage conditions on mechanical properties of resin composite blanks for CAD/CAM crowns10.4012/dmj.2019-202 ↗
40. Mechanical properties of composite resin blocks for CAD/CAM10.4012/dmj.2014-208 ↗
41. Influence of thermal cycling on flexural properties and simulated wear of computer-aided Design/Computer-aided manufacturing resin composites10.2341/16-046-L ↗
42. Influence of accelerated ageing on the physical properties of CAD/CAM restorative materials10.1007/s00784-019-03101-w ↗
43. Water uptake and strength characteristics of a nanofilled resin-based composite10.1016/j.jdent.2007.11.015 ↗
44. Does artificial aging affect mechanical properties of CAD/CAM composite materials10.1016/j.jpor.2017.06.001 ↗
45. Influence of water vapor on crack propagation in soda-lime glass10.1111/j.1151-2916.1967.tb15145.x ↗
46. Mechanical fatigue degradation of ceramics versus resin composites for dental restorations10.1016/j.dental.2014.01.003 ↗
47. Lifetime predictions for resin-based composites using cyclic and dynamic fatigue10.1002/1097-4636(2001)58:3<247::AID-JBM1013>3.0.CO;2-D ↗
48. Chairside CAD/CAM materials. Part 3: cyclic fatigue parameters and lifetime predictions10.1016/j.dental.2018.03.024 ↗
49. Mechanistic aspects of fatigue crack growth behavior in resin based dental restorative composites10.1016/j.dental.2009.01.097 ↗
50. Dynamic fatigue of composite CAD/CAM materials10.1016/j.jmbbm.2019.07.002 ↗