Degree of conversion and in vitro temperature rise of pulp chamber during polymerization of flowable and sculptable conventional, bulk-fill and short-fibre reinforced resin composites
Source abstract
Abstract
OBJECTIVE: Determine the degree of conversion (DC) and in vitro pulpal temperature (PT) rise of low-viscosity (LV) and high-viscosity (HV) conventional resin-based composites (RBC), bulk-fill and short-fibre reinforced composites (SFRC). METHODS: The occlusal surface of a mandibular molar was removed to obtain dentine thickness of 2 mm above the roof of the pulp chamber. LV and HV conventional (2 mm), bulk-fill RBCs (2-4 mm) and SFRCs (2-4 mm) were applied in a mold (6 mm inner diameter) placed on the occlusal surface. PT changes during the photo-polymerization were recorded with a thermocouple positioned in the pulp chamber. The DC at the top and bottom of the samples was measured with micro-Raman spectroscopy. ANOVA and Tukey's post-hoc test, multivariate analysis and partial eta-squared statistics were used to analyze the data (p < 0.05). RESULTS: The PT changes ranged between 5.5-11.2 °C. All LV and 4 mm RBCs exhibited higher temperature changes. Higher DC were measured at the top (63-76%) of the samples as compared to the bottom (52-72.6%) in the 2 mm HV conventional and bulk-fill RBCs and in each 4 mm LV and HV materials. The SFRCs showed higher temperature changes and DC% as compared to the other investigated RBCs. The temperature and DC were influenced by the composition of the material followed by the thickness. SIGNIFICANCE: Exothermic temperature rise and DC are mainly material dependent. Higher DC values are associated with a significant increase in PT. LV RBCs, 4 mm bulk-fills and SFRCs exhibited higher PTs. Bulk-fills and SFRCs applied in 4 mm showed lower DCs at the bottom.
Source: openalex_inverted_index · Quality: baseline
Research context
OpenAlex topics: Dental materials and restorations · Dental Erosion and Treatment · Endodontics and Root Canal Treatments
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (83)
Show source-provided references
1. Energy dependent polymerization of resin-based composite10.1016/S0109-5641(01)00069-0 ↗
2. Quantification of conversion degree and monomer elution from dental composite using HPLC and micro-Raman spectroscopy10.1007/s10337-014-2647-3 ↗
3. Factors affecting polymerization of resin-based composites: a literature review10.1016/j.sdentj.2017.01.002 ↗
4. Effect of light intensity and exposure duration on cure of resin composite
5. How light irradiance and curing time affect monomer conversion in light-cured resin composites10.1111/j.0909-8836.2003.00082.x ↗
6. Molar extinction coefficients and the photon absorption efficiency of dental photoinitiators and light curing units10.1016/j.jdent.2004.11.013 ↗
7. Insufficient cure under the condition of high irradiance and short irradiation time10.1016/j.dental.2008.07.007 ↗
8. Analysis of long-term monomer elution from bulk-fill and conventional resin-composites using high performance liquid chromatography10.1016/j.dental.2015.10.006 ↗
9. Evaluation of the degree of conversion, residual monomers and mechanical properties of some light-cured dental resin composites10.3390/ma12132109 ↗
10. Influence of various irradiation processes on the mechanical properties and polymerisation kinetics of bulk-fill resin based composites10.1016/j.jdent.2013.05.008 ↗
11. Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites10.1007/s00784-013-1177-y ↗
12. Light curing of resin-based composites in the LED era
13. Examining exposure reciprocity in a resin based composite using high irradiance levels and real-time degree of conversion values10.1016/j.dental.2015.02.010 ↗
14. Pulp response to externally applied heat10.1016/0030-4220(65)90015-0 ↗
15. Pulpal-temperature rise and polymerization efficiency of LED curing lights10.2341/09-203-L ↗
16. In-vitro pulp chamber temperature rise during composite resin polymerization with various light-curing sources10.1016/S0109-5641(99)00047-0 ↗
17. Comparison of in vivo and in vitro models to evaluate pulp temperature rise during exposure to a Polywave® LED light curing unit10.1590/1678-7757-2018-0480 ↗
18. Clinical and histological evaluation of thermal injury thresholds in human teeth: a preliminary study10.1111/j.1365-2842.1997.tb00278.x ↗
19. Influence of heat from light curing units and dental composite polymerization on cells in vitro10.1016/j.jdent.2005.07.004 ↗
20. Temperature excursions at the pulp-dentin junction during the curing of light-activated dental restorations10.1016/j.dental.2008.03.012 ↗
21. Thermal irritation of teeth during dental treatment procedures10.5395/rde.2013.38.3.105 ↗
22. Temperature rise produced by light sources and composites during curing10.1016/S0109-5641(86)80030-6 ↗
23. In vitro pulp chamber temperature rise from irradiation and exotherm of flowable composites10.1111/j.1365-263X.2007.00899.x ↗
24. Pulp chamber temperature changes with visible-light-cured composites in vitro10.1016/S0109-5641(05)80038-7 ↗
25. Initial fracture resistance and curing temperature rise of ten contemporary resin-based composites with increasing radiant exposure10.1016/j.jdent.2013.02.002 ↗
26. Comparison of temperature changes in the pulp chamber induced by various light curing units, in vitro10.2341/05-26 ↗
27. Temperature rise during adhesive and resin composite polymerization with various light curing sources
28. Thermographic analysis of the effect of composite type, layering method, and curing light on the temperature rise of photo-cured composites in tooth cavities10.1016/j.dental.2017.07.007 ↗
29. Effect of composite shade, increment thickness and curing light on temperature rise during photocuring10.1016/j.jdent.2006.07.012 ↗
30. Synthesis, characterization, shrinkage and curing kinetics of a new low-shrinkage urethane dimethacrylate monomer for dental application10.1016/j.dental.2007.03.004 ↗
31. Thermal diffusivity of composite restorative materials10.1177/00220345870660101201 ↗
32. Monomer conversion, microhardness, internal marginal adaptation, and shrinkage stress of bulk-fill resin composites10.1016/j.dental.2015.10.001 ↗
33. Curing behaviour of high-viscosity bulk-fill composites10.1016/j.jdent.2014.05.012 ↗
34. Degree of conversion and BisGMA, TEGDMA, UDMA elution from flowable bulk-fill composites10.3390/ijms17050732 ↗
35. Influence of increment thickness on light transmission, degree of conversion and micro hardness of bulk fill composites10.1007/s10266-015-0227-0 ↗
36. Comparison of photopolymerization temperature increases in internal and external positions of composite and tooth cavities in real time: incremental fillings of microhybrid composite vs. bulk filling of bulk fill composite10.1016/j.jdent.2015.07.003 ↗
37. Intrapulpal temperature changes during curing of different bulk-fill restorative materials10.4012/dmj.2016-200 ↗
38. Influence of bulk-fill composites, polimerization modes, and remaining dentin thickness on intrapulpal temperature rise10.1155/2019/4250284 ↗
39. Retrospective evaluation of posterior direct composite restorations: 10-year findings10.1016/j.dental.2014.11.001 ↗
40. Physical properties and depth of cure of a new short fiber reinforced composite10.1016/j.dental.2013.04.016 ↗
41. In vitro fracture resistance of molar teeth restored with a short fibre-reinforced composite material10.1016/j.jdent.2014.05.004 ↗
42. A review of heat transfer in human tooth – experimental characterization and mathematical modeling10.1016/j.dental.2010.02.009 ↗
43. Light transmission characteristics of dentine and resin composites with different thickness10.1016/j.jdent.2012.08.016 ↗
44. Light energy transmission through cured resin composite and human dentin
45. Temperature related changes in pulpal microcirculation
46. Effect of simulated pulpal microcirculation on intrapulpal temperature changes following application of heat on tooth surfaces10.1111/j.1365-2591.2008.01508.x ↗
47. Robust spectrometer-based methods for characterizing radiant exitance of dental LED curing units10.1016/j.dental.2015.02.012 ↗
48. Light output from six battery operated dental curing lights10.1016/j.msec.2016.07.033 ↗
49. Emission characteristics and effect of battery drain in “budget” curing lights10.2341/14-281-L ↗
50. Microscopic observations on living dental pulp II. The effect of thermal irritants on the circulation of the pulp in the lower rat incisor10.3109/00016355809064116 ↗
51. Light curing in dentistry and clinical implications: a literature review
52. Temperature rise induced by some light emitting diode and quartz-tungsten-halogen curing units10.1111/j.1600-0722.2004.00181.x ↗
53. Effect of composite temperature on in vitro intrapulpal temperature rise10.1016/j.dental.2006.11.024 ↗
54. Temperature rise during polymerization of light-activated resin composites10.1046/j.1365-2842.1998.00336.x ↗
55. Thermographic investigation of contemporary resin-containing materials10.1016/j.jdent.2005.01.010 ↗
56. Effect of light power density variations on bulk curing properties of dental composites10.1016/S0300-5712(03)00015-0 ↗
57. Temperature rise and degree of photopolymerization conversion of nanocomposites and conventional dental composites10.1007/s00784-008-0236-2 ↗
58. Effect of exposure time and pre-heating on the conversion degree of conventional, bulk-fill, fiber reinforced and polyacid-modified resin composites10.1016/j.dental.2018.11.017 ↗
59. Reducing the gel effect in free radical polymerization10.1016/S0009-2509(00)00305-5 ↗
60. Temperature change caused by light curing of fiber-reinforced composite resins10.4103/0972-0707.157258 ↗
61. The effects of extended curing time and radiant energy on microhardness and temperature rise of conventional and bulk-fill resin composites10.1007/s00784-019-02807-1 ↗
62. Peak temperatures of some prosthetic acrylates on polymerization10.1046/j.1365-2842.1996.00430.x ↗
63. In vivo temperature rise in anesthetized human pulp during exposure to a polywave LED light curing unit10.1016/j.dental.2015.02.001 ↗
64. Microstructural changes of enamel, dentin-enamel junction, and dentin induced by irradiating outer enamel surfaces with CO2laser10.1007/s10103-007-0453-y ↗
65. Light transmission on dental resin composites10.1016/j.dental.2007.06.015 ↗
66. How filler properties, filler fraction, sample thickness and light source affect light attenuation in particulate filled resin composites10.1016/j.dental.2005.01.002 ↗
67. Effect of high-intensity curing lights on the polymerization of bulk-fill composites10.1016/j.dental.2018.06.005 ↗
68. Correlation between hardness and degree of conversion during the setting reaction of unfilled dental restorative resins10.1016/S0109-5641(85)80058-0 ↗
69. Degree of conversion of bulk-fill compared to conventional resin-composites at two time intervals10.1016/j.dental.2013.05.011 ↗
70. The effect of filler and silane content on conversion of resin-based composite10.1016/S0109-5641(02)00062-3 ↗
71. Polymerization efficiency and flexural strength of low-stress restorative composites10.1016/j.dental.2014.03.006 ↗
72. GC Australia, EverX Flow 2019 http://www.gcaustralasia.com/Upload/product/pdf/112/F575_EverX-Flow-brochure_FinalWS_17052019.pdf. [Accessed 23 October 2020].
73. Effects of monomer ratios and highly radiopaque fillers on degree of conversion and shrinkage-strain of dental resin composites10.1016/j.dental.2009.06.009 ↗
74. Influence of TEGDMA monomer on MMP-2, MMP-8, and MMP-9 production and collagenase activity in pulp cells
75. Wear and marginal breakdown of composites with various degrees of cure10.1177/00220345970760081401 ↗
76. Light intensity effect on resin-composite degree of conversion and shrinkage strain10.1016/S0109-5641(00)00020-8 ↗
77. Dentsply Sirona, SDR Flow+ Bulk Fill Flowable 2017 https://assets.dentsplysirona.com/flagship/en/explore/restorative/sdr_flow_plus_euversion/SM%20SDR%20FlowPlus%20V01%202017-12-08.pdf. [Accessed 23 October 2020].
78. Application of an addition-fragmentation-chain transfer monomer in di(meth)acrylate network formation to reduce polymerization shrinkage stress10.1039/C7PY00702G ↗
79. A study of temperature rise in the pulp chamber during composite polymerization with different light curing units10.5005/jcdp-8-7-29 ↗
80. Drilling of bone: a comprehensive review10.1016/j.jcot.2013.01.002 ↗
81. The influence of the chosen in vitro bone simulation model on intraosseous temperatures and drilling times10.1038/s41598-019-48416-6 ↗
82. Effect of light-curing exposure time, shade, and thickness on the depth of cure of bulk fill composites10.2341/16-057-L ↗
83. Polymerization shrinkage and depth of cure of bulk-fill resin composites and highly filled flowable resin10.2341/13-307-L ↗