journal article·2022-12

Ion releasing direct restorative materials: Key mechanical properties and wear

Rawan Daabash, Abdulrahman Alshabib, Mohammed Q. Alqahtani, Richard Bengt Price, Nick Silikas, Maan M. Alshaafi

Dental Materials· Volume 38· Issue 12
Publisher page

Abstract

Objectives To investigate the depth of cure (DoC), fracture toughness (KIC) and wear of ion releasing resin-based composite (RBC) restorative materials. Methods Two ion releasing RBCs, Activa (ACT) and Cention-N (CN) were compared to a conventional RBC (Z350) and a resin-modified glass ionomer cement (Fuji-II-LC). The DoC was measured in a 10-mm deep semi-circular metal mold with a 2-mm internal radius (n = 8). The molds were irradiated from one end for 20-s. The Knoop hardness (KH) was measured at 0.5-mm intervals from the surface after the specimens had been stored at 37 °C for 24-h. To measure the KIC, single-edge-notched specimens (n = 15/group) were prepared (25×5x2.5-mm) for a 3-point bending test and then stored for either 1 or 30-days in water at 37 °C. Disk-shaped specimens (n = 10) were subjected to 250,000-load cycles of 49-N using a chewing simulator against spherical steatite antagonists. DoC and wear data were analyzed by one-way ANOVA and Tukey post hoc tests (p ≤ 0.05). KIC data were analyzed by two-way ANOVA and one-way ANOVA, and the Tukey post hoc test (p ≤ 0.05). In addition, an independent t-test was used to determine if storage time had any effect (α = 0.05) on the KIC of each material. Results Maximum hardness value was the highest for Z350 and the lowest for ACT. The depth at which 80% of the maximum KH, was the highest for CN (9.2 mm) and the lowest for Z350 (2 mm). All tested materials met the manufacturers' claims for DoC. After 1-day, the highest KIC values were recorded for ACT and the lowest for Fuji-II-LC. Water storage (30-days) significantly reduced the KIC value for all materials except Fuji-II-LC. The highest wear rate values were recorded for CN followed by ACT. Significance All tested materials met their manufacturers' claims for DoC. Water storage for 30-days significantly reduced the fracture toughness for ACT and CN. Wear was significantly higher for ACT and CN.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Bone Tissue Engineering Materials

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (73)

Show source-provided references
1. Probing the hierarchy of evidence to identify the best strategy for placing class II dental composite restorations using current materials10.1111/jerd.12686 ↗
2. The evolution of dental materials over the past century: silver and gold to tooth color and beyond10.1177/0022034518822808 ↗
3. The Minamata Convention and the phase down of dental amalgam10.2471/BLT.17.203141 ↗
4. A randomized controlled 30 years follow up of three conventional resin composites in Class II restorations10.1016/j.dental.2015.08.146 ↗
5. Clinical performance of posterior resin composite restorations after up to 33 years10.1016/j.dental.2022.02.009 ↗
6. Guidance on posterior resin composites: academy of Operative Dentistry - European Section10.1016/j.jdent.2014.01.009 ↗
7. Longevity of posterior composite restorations: not only a matter of materials10.1016/j.dental.2011.09.003 ↗
8. Direct composite resin fillings versus amalgam fillings for permanent or adult posterior teeth
9. An update on the reasons for placement and replacement of direct restorations10.1016/j.jdent.2018.03.001 ↗
10. Ageing of dental composites based on methacrylate resins-a critical review of the causes and method of assessment
11. Relation of dental composite formulations to their degradation and the release of hydrolyzed polymeric-resin-derived products10.1177/10454411010120020401 ↗
12. Relaxation of polymerization contraction shear stress by hygroscopic expansion10.1177/00220345900690010501 ↗
13. Factors involved in mechanical fatigue degradation of dental resin composites10.1177/0022034513490734 ↗
14. Martos J., Willy P., Osinaga R., De Oliveira E., Antônio L., De Castro S. Hydrolytic Degradation of Composite Resins: Effects on the Microhardness 2003;6:599–604.10.1590/S1516-14392003000400029 ↗
15. Bioactive dental materials—do they exist and what does bioactivity mean10.1016/j.dental.2018.03.001 ↗
16. Inert to bioactive – a multidimensional spectrum10.1016/j.dental.2021.11.002 ↗
17. The story of bioglass10.1007/s10856-006-0432-z ↗
18. Dental glass ionomer cements as permanent filling materials? – properties, limitations and future trends10.3390/ma3010076 ↗
19. Mechanical strength and wear of dental glass-ionomer and resin composites affected by porosity and chemical composition10.1007/s40735-015-0025-9 ↗
20. Fracture toughness of dental restorative materials10.1007/s00784-011-0525-z ↗
21. A review of bioceramics-based dental restorative materials10.4012/dmj.2018-039 ↗
22. Review of fluoride release and secondary caries reduction by fluoridating composites10.1177/08959374950090040501 ↗
23. Dental repair material: a resin-modified glass-ionomer bioactive ionic resin-based composite
24. Characterization of fluoride releasing restorative dental materials10.4012/dmj.2017-161 ↗
25. Flexural strength and flexural fatigue properties of resin-modified glass ionomers
26. Ivoclar Vivadent. Cention N. – scientific documentation n.d.
27. Evaluation of F, Ca, and P release and microhardness of eleven ion-leaching restorative materials and the recharge efficacy using a new Ca/P containing fluoride varnish10.1016/j.jdent.2020.103474 ↗
28. Characterization of the bioactivity of two commercial composites10.1016/j.dental.2019.10.004 ↗
29. Development and characterization of ion-releasing fiber-reinforced flowable composite10.1016/j.dental.2022.08.006 ↗
30. Effect of High Irradiance on Depth of Cure of a Conventional and a Bulk Fill Resin-based Composite10.2341/14-244-L ↗
31. Influence of test method on failure stress of brittle dental materials10.1177/00220345900690120201 ↗
32. Practical and theoretical considerations on the fracture toughness testing of dental restorative materials10.1016/j.dental.2017.11.016 ↗
33. Laboratory mechanical parameters of composite resins and their relation to fractures and wear in clinical trials—a systematic review10.1016/j.dental.2016.11.013 ↗
34. A critical evaluation of fatigue studies for restorative materials in dentistry10.1007/s40496-016-0097-8 ↗
35. Is the wear of dental composites still a clinical concern? Is there still a need for in vitro wear simulating devices?10.1016/j.dental.2006.02.005 ↗
36. ASTM D-14. Standard Test Method for Plane-Strain Fracture Toughness of Metallic Materials. Am Soc Test Mater 2014. https://www.astm.org/e0399–90r97.html (accessed February 15, 2022).
37. The effect of aging methods on the fracture toughness and physical stability of an oxirane/acrylate, ormocer, and Bis-GMA-based resin composites
38. The fracture toughness of dental composites. I. The development of strength and fracture toughness10.1111/j.1365-2842.1982.tb00535.x ↗
39. Post-irradiation polymerization of visible light-activated composite resin
40. Post-cure depth of cure of bulk fill dental resin-composites10.1016/j.dental.2013.10.011 ↗
41. Hardness and fracture toughness of resin-composite materials with and without fibers10.1016/j.dental.2019.05.017 ↗
42. Resin composite—state of the art10.1016/j.dental.2010.10.020 ↗
43. Curing characteristics of flowable and sculptable bulk-fill composites10.1007/s00784-016-1894-0 ↗
44. Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites10.1007/s00784-013-1177-y ↗
45. Scientific documentation: cention N. Ivoclar-vivadent press schaan
46. GC Corporation. GC America | GC Fuji II LC® CAPSULE - Light-Cured Restorative n.d.
47. Resin modified glass-ionomers: strength, cure depth and translucency10.1111/j.1834-7819.2002.tb00548.x ↗
48. Depth of cure of resin-modified glass ionomers10.1016/0109-5641(95)80018-2 ↗
49. Delayed photoactivation of dual-cure composites: effect on cuspal flexure, depth-of-cure, and mechanical properties10.2341/18-140-L ↗
50. Bahbishi N., Mzain W., Badeeb B., Nassar H.M. Color Stability and Micro-Hardness of Bulk-Fill Composite Materials after Exposure to Common Beverages. Mater 2020, Vol 13, Page 787 2020;13:787. https://doi.org/10.3390/MA13030787.10.3390/ma13030787 ↗
51. Mechanical and tribological characterization of a bioactive composite resin10.3390/app11178256 ↗
52. Multiple correlations of material parameters of light-cured dental composites10.1016/j.dental.2009.03.011 ↗
53. Academy of dental materials guidance—resin composites: part I—mechanical properties10.1016/j.dental.2017.04.013 ↗
54. Commercially available fluoride-releasing restorative materials: a review and a proposal for classification
55. Comprehensive characterisation of flexural mechanical properties and a new classification for porosity of 11 contemporary ion-leaching dental restorative materials10.1016/j.jmbbm.2021.104615 ↗
56. Variables affecting the fracture toughness of dental composites10.1177/00220345870660060901 ↗
57. Effect of thermocycling on biaxial flexural strength of CAD/CAM, bulk fill, and conventional resin composite materials10.2341/18-146-L ↗
58. Filler characteristics of modern dental resin composites and their influence on physico-mechanical properties10.1016/j.dental.2016.09.034 ↗
59. Evaluation of physico-mechanical properties and filler particles characterization of conventional, bulk-fill, and bioactive resin-based composites10.1016/j.jmbbm.2020.104288 ↗
60. Material properties and fractography of an indirect dental resin composite10.1016/j.dental.2010.02.008 ↗
61. Effect of one-year water storage on the surface microhardness of resin-modified versus conventional glass-ionomer cements10.1016/S0109-5641(02)00042-8 ↗
62. Compressive strength of resin-modified glass ionomer restorative material: effect of P/L ratio and storage time10.1590/S1678-77572005000400008 ↗
63. Hollow glass fibers in reinforcing glass ionomer cements10.1016/j.dental.2016.10.004 ↗
64. Wear of dental materials: clinical significance and laboratory wear simulation methods —a review10.4012/dmj.2018-140 ↗
65. Occlusal forces during chewing and swallowing as measured by sound transmission10.1016/0022-3913(81)90455-8 ↗
66. The wear of dental amalgam in an artificial mouth: a clinical correlation10.1016/S0109-5641(85)80050-6 ↗
67. The relationship between physical parameters and wear of dental composites10.1016/j.wear.2006.12.010 ↗
68. Filler features and their effects on wear and degree of conversion of particulate dental resin composites10.1016/j.biomaterials.2005.01.026 ↗
69. Friedrich K., Reinicke R., Zhang Z. Wear of polymer composites: Http://DxDoiOrg/101243/135065002762355334 2005;216:415–26. https://doi.org/10.1243/135065002762355334.10.1243/135065002762355334 ↗
70. Wear of dental resin composites: insights into underlying processes and assessment methods--a review10.1002/jbm.b.10563 ↗
71. Bioactive glass particulate filler composite: effect of coupling of fillers and filler loading on some physical properties10.1016/j.dental.2014.02.017 ↗
72. In vitro wear of dual-cured bulkfill composites and flowable bulkfill composites10.1111/jerd.12616 ↗
73. Wear behavior and surface quality of dental bioactive ions-releasing resins under simulated chewing conditions10.3389/froh.2021.628026 ↗