journal article·2023-03

Ability of short exposures from laser and quad-wave curing lights to photo-cure bulk-fill resin-based composites

Cristiane Maucoski, Richard Bengt Price, Mateus Garcia Rocha, Jean-François Roulet, Braden Sullivan

Dental Materials· Volume 39· Issue 3
Publisher page

Abstract

Objective This study investigated the ability of a laser, and a 'quad-wave' LCU, to photo-cure paste and flowable bulk-fill resin-based composites (RBCs). Methods Five LCUs and nine exposure conditions were used. The laser LCU (Monet) used for 1 s and 3 s, the quad-wave LCU (PinkWave) used for 3 s in the Boost and 20 s in the Standard modes, the the multi-peak LCU (Valo X) used for 5 s in the Xtra and 20 s in the Standard modes, were compared to the polywave PowerCure used in the 3 s mode and for 20 s in the Standard mode, and to the mono-peak SmartLite Pro used for 20 s. Two paste consistency bulk-fill RBCs: Filtek One Bulk Fill Shade A2 (3 M), Tetric PowerFill Shade IVA (Ivoclar Vivadent), and two flowable RBCs: Filtek Bulk Fill Flowable Shade A2 (3 M), Tetric PowerFlow Shade IVA (Ivoclar Vivadent) were photo-cured in 4-mm deep x 4-mm diameter metal molds. The light received by these specimens was measured using a spectrometer (Flame-T, Ocean Insight), and the radiant exposure delivered to the top surface of the RBCs was mapped. The immediate degree of conversion (DC) at the bottom, and the 24-hour Vickers Hardness (VH) at the top and bottom of the RBCs were measured and compared. Results The irradiance received by the 4-mm diameter specimens ranged from 1035 mW/cm2 (SmartLite Pro) to 5303 mW/cm2 (Monet). The radiant exposures between 350 and 500 nm delivered to the top surface of the RBCs ranged from 5.3 J/cm2 (Monet in 1 s) to 26.4 J/cm2 (Valo X), although the PinkWave delivered 32.1 J/cm2 in 20 s 350 to 900 nm. All four RBCs achieved their maximum DC and VH values at the bottom when photo-cured for 20 s. The Monet used for 1 s and the PinkWave used for 3 s on the Boost setting delivered the lowest radiant exposures between 420 and 500 nm (5.3 J/cm2 and 3.5 J/cm2 respectively), and they produced the lowest DC and VH values. Conclusions Despite delivering a high irradiance, the short 1 or 3-s exposures delivered less energy to the RBC than 20-s exposures from LCUs that deliver> 1000 mW/cm2. There was an excellent linear correlation (r > 0.98) between the DC and the VH at the bottom. There was a logarithmic relationship between the DC and the radiant exposure (Pearson's r = 0.87-97) and between the VH and the radiant exposure (Pearson's r = 0.92-0.96) delivered in the 420-500 nm range.
Source: europepmc · Quality: candidate unverified · Source record ↗

Research context

OpenAlex topics: Dental materials and restorations · Photopolymerization techniques and applications · Laser Material Processing Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

References (83)

Show source-provided references
1. WHO · 2022 · 120
2. Clinical efficacy of resin-based direct posterior restorations and glass-ionomer restorations - An updated meta-analysis of clinical outcome parameters10.1016/j.dental.2021.10.018 ↗
3. Clinical performance of posterior resin composite restorations after up to 33 years10.1016/j.dental.2022.02.009 ↗
4. Longevity of composite restorations is definitely not only about materials
5. Direct composite resin fillings versus amalgam fillings for permanent posterior teeth
6. Longevity of direct restorations in stress-bearing posterior cavities: a retrospective study10.2341/12-432-C ↗
7. Wear and marginal breakdown of composites with various degrees of cure10.1177/00220345970760081401 ↗
8. Resin composite properties and energy density of light cure10.1177/154405910508400715 ↗
9. Light curing in dentistry and clinical implications: a literature review10.1590/1807-3107bor-2017.vol31.0061 ↗
10. The effect of curing conditions on the dentin bond strength of two dual-cure resin cements10.1016/j.jpor.2016.12.012 ↗
11. Shear bond strength with increasing light-guide distance from dentin10.2310/6130.2006.00007 ↗
12. Long-term elution of bisphenol A from dental composites10.1016/j.dental.2021.08.005 ↗
13. Effect of the degree of conversion of resin-based composites on cytotoxicity, cell attachment, and gene expression10.1016/j.dental.2019.05.015 ↗
14. Improper Light Curing of Bulkfill Composite Drives Surface Changes and Increases S. mutans Biofilm Growth as a Pathway for Higher Risk of Recurrent Caries around Restorations
15. Direct and indirect monomer elution from an RBC product family10.1016/j.dental.2021.08.011 ↗
16. Long-Term Stability of a RAFT-Modified Bulk-Fill Resin-Composite under Clinically Relevant Versus ISO-Curing Conditions
17. Correlation of the degree of conversion with the amount of elutable substances in nano-hybrid dental composites10.1016/j.dental.2012.08.006 ↗
18. Longevity of posterior composite restorations: a systematic review and meta-analysis10.1177/0022034514544217 ↗
19. Secondary caries: prevalence, characteristics, and approach10.1007/s00784-019-02894-0 ↗
20. Effect of distance on the power density from two light guides10.1111/j.1708-8240.2000.tb00241.x ↗
21. Radiant-exposure attenuation through Class-2 proximal slots
22. Study of energy transfer by different light curing units into a class III restoration as a function of tilt angle and distance, using a MARC Patient Simulator (PS)10.1016/j.dental.2016.02.007 ↗
23. Factors affecting the energy delivered to simulated class I and class v preparations
24. The light-curing unit: An essential piece of dental equipment10.1111/idj.12582 ↗
25. Light-curing units: a review of what we need to know10.1177/0022034515594786 ↗
26. Polymerization shrinkage, microhardness and depth of cure of bulk fill resin composites10.4012/dmj.2018-063 ↗
27. Degree of Conversion and Polymerization Shrinkage of Bulk-Fill Resin-Based Composites10.2341/16-027-L ↗
28. CMD. FlashMax P3 Product description. 2021. CMS Dental; Glyngøre, Roslev, Denmark. 〈https://cmsdental.com/en/products/flashmax-p3〉. Accessed November 1, 2022.
29. AMD. Monet Laser Curing Light. The 1 second revolution. 2021. AMD, West Jordan, UT. 〈https://www.amdlasers.com/products/monet-laser-curing-light〉. Accessed November 1, 2022.
30. ApexVista. PinkWave Instructions for Use. 2021. ApexVista, Racine, WI. 〈https://vistaapex.com/pinkwave〉. Accessed November 1, 2022.
31. BAPO as an alternative photoinitiator for the radical polymerization of dental resins10.1016/j.dental.2014.05.020 ↗
32. Role of filler and functional group conversion in the evolution of properties in polymeric dental restoratives10.1016/j.dental.2014.02.015 ↗
33. The reciprocity law concerning light dose relationships applied to BisGMA/TEGDMA photopolymers: theoretical analysis and experimental characterization10.1016/j.dental.2014.02.021 ↗
34. 3s PowerCure: Scientific Documentation, 2019. Ivoclar Vivadent AG, Schaan/Liechtenstein.Accessed November 1, 2022.
35. Exposure reciprocity law in photopolymerization of multi-functional acrylates and methacrylates10.1002/macp.200600480 ↗
36. Examining exposure reciprocity in a resin based composite using high irradiance levels and real-time degree of conversion values10.1016/j.dental.2015.02.010 ↗
37. Polymerization of resin composite restorative materials: exposure reciprocity10.1016/S0109-5641(02)00101-X ↗
38. Applicability of exposure reciprocity law for fast polymerization of restorative composites containing various photoinitiating systems10.2341/20-112-L ↗
39. High irradiance curing and anomalies of exposure reciprocity law in resin-based materials10.1016/j.jdent.2011.05.007 ↗
40. Limited reciprocity in curing efficiency of bulk-fill resin-composites10.1016/j.dental.2020.04.019 ↗
41. Photoinitiator type and applicability of exposure reciprocity law in filled and unfilled photoactive resins10.1016/j.dental.2010.09.011 ↗
42. Resin viscosity determines the condition for a valid exposure reciprocity law in dental composites10.1016/j.dental.2019.12.003 ↗
43. Effects of different photo-polymerization protocols on resin-dentine muTBS, mechanical properties and cross-link density of a nano-filled resin composite10.1016/j.jdent.2012.05.014 ↗
44. Reporting of light irradiation conditions in 300 laboratory studies of resin-composites10.1016/j.dental.2018.12.001 ↗
45. ISO 10650 Dentistry-Powered polymerization activators. Geneva, Switzerland: International Standards Organization: International Standards Organization; 2015. p. 14.
46. Pulp chamber heating: an in vitro study evaluating different light sources and resin composite layers10.1590/0103-6440201600328 ↗
47. Academy of Dental Materials guidance-Resin composites: Part II-Technique sensitivity (handling, polymerization, dimensional changes)10.1016/j.dental.2017.08.188 ↗
48. Fast Curing with High-power Curing Lights Affects Depth of Cure and Post-gel Shrinkage and Increases Temperature in Bulk-fill Composites10.2341/21-160-L ↗
49. Insufficient cure under the condition of high irradiance and short irradiation time10.1016/j.dental.2008.07.007 ↗
50. Delayed Gelation Through Chain-Transfer Reactions: Mechanism For Stress Reduction In Methacrylate Networks10.1016/j.polymer.2011.05.034 ↗
51. Influence of light intensity on two restorative systems10.1016/0300-5712(95)93577-O ↗
52. Effect of rapid high-intensity light-curing on polymerization shrinkage properties of conventional and bulk-fill composites10.1016/j.jdent.2020.103448 ↗
53. Impact of fast high-intensity versus conventional light-curing protocol on selected properties of dental composites
54. The effect of light intensity on double bond conversion and flexural strength of a model, unfilled dental resin10.1016/S0109-5641(02)00090-8 ↗
55. A mechanism on why slower polymerization of a dental composite produces lower contraction stress10.1002/jbm.b.30453 ↗
56. Influence of curing protocol on selected properties of light-curing polymers: degree of conversion, volume contraction, elastic modulus, and glass transition temperature10.1016/j.dental.2009.08.001 ↗
57. Conversion kinetics of rapid photo-polymerized resin composites10.1016/j.dental.2020.07.008 ↗
58. Polymerization shrinkage and shrinkage stress development in ultra-rapid photo-polymerized bulk fill resin composites10.1016/j.dental.2021.02.012 ↗
59. Outcomes of ultra-fast (3 s) photo-cure in a RAFT-modified resin-composite10.1016/j.dental.2020.02.007 ↗
60. Reaction kinetics and mechanics in photo-polymerised networks10.1016/j.dental.2004.10.003 ↗
61. The effect of cure rate on the mechanical properties of dental resins10.1016/S0109-5641(01)00010-0 ↗
62. Increased rates of photopolymerisation by ternary type II photoinitiator systems in dental resins10.1016/j.jmbbm.2019.06.005 ↗
63. Quantum yield of conversion of the photoinitiator camphorquinone10.1016/j.dental.2006.06.005 ↗
64. The photoinitiators used in resin based dental composite-a review and future perspectives
65. Recent developments of new components for dental adhesives and composites10.1002/mame.200600414 ↗
66. β-allyl sulfones as addition–fragmentation chain transfer reagents: a tool for adjusting thermal and mechanical properties of dimethacrylate networks10.1021/ma501550b ↗
67. In vitro temperature changes in the pulp chamber caused by laser and Quadwave LED-light curing units
68. Temperature changes and hardness of resin-based composites light-cured with laser diode or light-emitting diode curing lights
69. Depth of cure of 10 resin-based composites light-activated using a laser diode, multi-peak, and single-peak light-emitting diode curing lights10.1016/j.jdent.2022.104141 ↗
70. A Blinded Comparative Study of Four Commercially Available LEDs and a Laser Light Curing Device
71. Effect of time on the post-irradiation curing of six resin-based composites10.1016/j.dental.2020.04.024 ↗
72. ISO 4049 · 2019 · 27
73. Depth of cure of resin composites: is the ISO 4049 method suitable for bulk fill materials?10.1016/j.dental.2012.02.002 ↗
74. New insight into the "depth of cure" of dimethacrylate-based dental composites10.1016/j.dental.2011.12.004 ↗
75. Curing characteristics of a composite. part 2: the effect of curing configuration on depth and distribution of cure10.1016/j.dental.2014.02.013 ↗
76. Effect of mold diameter on the depth of cure of a resin-based composite material10.1111/eos.12325 ↗
77. Effect of mold type, diameter, and uncured composite removal method on depth of cure10.1007/s00784-015-1672-4 ↗
78. Effect of mold type and diameter on the depth of cure of three resin-based composites10.2341/17-122-L ↗
79. In vivo pulp temperature changes during class V cavity preparation and resin composite restoration in premolars10.2341/20-098-C ↗
80. The effect of specimen temperature on the polymerization of a resin-composite10.1016/j.dental.2011.06.004 ↗
81. Effect of the sample preparation and light-curing unit on the microhardness and degree of conversion of bulk-fill resin-based composite restorations10.2341/20-043-L ↗
82. Transmission of violet and blue light through conventional (layered) and bulk cured resin-based composites10.1016/j.jdent.2016.06.007 ↗
83. Delayed post-curing stage and oxygen inhibition of free-radical polymerization of dimethacrylate resin10.1016/j.dental.2018.06.019 ↗