Influence of crosshead speed on micro-tensile bond strength of two-step adhesive systems
Source abstract
Abstract
Objectives The purpose of this study was to determine the influence of crosshead speed on the micro-tensile bond strength of two separate adhesive systems to dentin. Methods The systems used were the Clearfil SE Bond (Kuraray Medical) and the Single Bond (3M ESPE) combined with a resin composite Clearfil AP-X (Kuraray Medical). Dentin surfaces of bovine madibular incisors were primed with self-etching primer followed by air blowing for Clearfil SE Bond, or etched with phosphoric acid followed by rinsing with distilled water for Single Bond, and adhesive was applied. The resin composite was then built up in three layers and light activated. After 24 h storage in water, specimens were sectioned and trimmed to a cross-sectional area of 1 mm(2) and subjected to a micro-tensile bond-strength test. Ten samples per test group were tested at crosshead speeds of 0.5, 1.0, 5.0 and 10.0 mm/min. Micro-tensile bond-strength values (in MPa) were calculated from the peak load at failure divided by the specimen surface area. Two-way ANOVA was performed at the 0.05 probability level. Results The mean dentin bond strength at different crosshead speeds ranged from 34.6 to 37.1MPa for Clearfil SE Bond and from 44.3 to 50.4 MPa for Single Bond. There was no significant difference among the same adhesive systems with the different crosshead speeds tested. Significance The influence of the crosshead speed might be negligible when measuring micro-tensile bond strengths.
Source: europepmc · Quality: candidate unverified · Source record ↗
Research context
OpenAlex topics: Dental materials and restorations · Endodontics and Root Canal Treatments · Dental Erosion and Treatment
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (31)
Show source-provided references
1. Dentin bonding: questions for the new millennium
2. Dental adhesives of the future
3. Buonocore memorial lecture. Adhesion to enamel and dentin: current status and future challenges
4. Bonding of restorative materials to dentine: the present status in Japan
5. Adhesion testing of dentin bonding agents: a review10.1016/0109-5641(95)80046-8 ↗
6. Dentin bonding system. Part I: literature review
7. The microtensile bond test: a review
8. Standardizing laboratory adhesion tests
9. Correlation of in vivo and in vitro performance of adhesive restorative materials: a report of the ASC MD156 Task Group on Test Methods for the Adhesion of Restorative Materials10.1016/0109-5641(91)90049-5 ↗
10. Do dentin bond strength tests serve a useful purpose?
11. The effect of local interfacial geometry on the measurement of the tensile bond strength to dentin10.1177/00220345910700050501 ↗
12. Why do shear bond tests pull out dentin?10.1177/00220345970760061001 ↗
13. A critique of bond strength measurements10.1016/0300-5712(89)90131-0 ↗
14. Dentin bonding system. Part II: effect of crosshead speed
15. Assessment by nano-indentation of the hardness and elasticity of the resin–dentin bonding area10.1177/00220345930720101401 ↗
16. Influence of cross-head speed on resin–dentin shear bond strength10.1016/S0109-5641(00)00060-9 ↗
17. Slow crack growth in brittle materials under dynamic loading conditions10.1007/BF00113930 ↗
18. Influence of test method on failure stress of brittle dental materials10.1177/00220345900690120201 ↗
19. Size effect in resin/glass composite flexure strengths10.1046/j.1365-2842.1999.00451.x ↗
20. An asymptotic approach to size effect on fracture toughness and fracture energy of composites10.1016/S0013-7944(01)00102-3 ↗
21. Relationship between surface area for adhesion and tensile bond strength: evaluation of a micro-tensile bond test10.1016/0109-5641(94)90067-1 ↗
22. Effect of cross-sectional surface area on bond strengths between resin and dentin10.1016/S0109-5641(98)00018-9 ↗
23. The influence of cross-sectional shape and surface area on the microtensile bond test10.1016/S0109-5641(98)00034-7 ↗
24. Influence of substrate, shape, and thickness on microtensile specimens' structural integrity and their measured bond strengths10.1016/j.dental.2003.08.009 ↗
25. Bovine teeth as possible substitutes in the adhesion test10.1177/00220345830620101501 ↗
26. Influence of selected variables on adhesion testing10.1016/0109-5641(92)90097-V ↗
27. Bovine dentin as a substitute for human dentin in shear bond strength measurements
28. Three-dimensional finite element analysis of the shear bond test10.1016/0109-5641(95)80047-6 ↗
29. Calculation models for average stress and plastic deformation zone size of bonding area in dentine bonding systems10.4012/dmj.14.152 ↗
30. Stress fatigue: basic principles and prosthodontic implications
31. Strain rate effects on the transverse compressive and shear behavior of unidirectional composites10.1177/002199839903301703 ↗